User manual OMRON H3YN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H3YN. We hope that this OMRON H3YN user guide will be useful to you.

Lastmanuals help download the user guide OMRON H3YN.


Mode d'emploi OMRON H3YN
Download
Manual abstract: user guide OMRON H3YN

Detailed instructions for use are in the User's Guide.

[. . . ] 2. 2 VA (1. 8 W) at 230 VAC, 60 Hz Relay OFF: approx. 1. 5 VA (1. 1 W) at 230 VAC, 60 Hz 24 VAC: Relay ON: approx. 1. 8 VA (1. 4 W) at 24 VAC, 60 Hz Relay OFF: approx. 0. 3 VA (0. 2 W) at 24 VAC, 60 Hz 12 VDC: Relay ON: approx. [. . . ] 50 g (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: EN61000-4-2: 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 2 kV line to ground (level 3) 1 kV line to line (level 3) UL508, CSA C22. 2 No. 14, Lloyds Conforms to EN61812-1 and IEC60664-1. (2. 5 kV/2 for H3YN-2/-21, 2. 5 kV/1 for H3YN-4/-41, H3YN4-Z/-41-Z) Output category according to EN60947-5-1. Impulse withstand voltage Noise immunity Static immunity Degree of protection Weight EMC Approved standards Note: 1. Refer to the Life-test Curve. Solid-state Timer H3YN B-87 Life-test Curve (Reference Value) H3YN-2/-21 Switching operations (x 103) 5, 000 250 VAC, cos = 1 24 VDC, cos = 1 Switching operations (x 103) 5, 000 250 VAC, cos = 0. 4 24 VDC, L/R = 7 ms 1, 000 500 200 1, 000 500 200 Load current (A) Load current (A) Reference: A maximum current of 0. 6 A can be switched at 125 VDC (cos = 1). Maximum current of 0. 2 A can be switched if L/R is 7 ms. In both cases, a life of 100, 000 operations can be expected. The minimum applicable load is 1 mA at 5 VDC (P reference value). H3YN-4/-41 Switching operations (x 103) 5, 000 250 VAC, cos = 1 24 VDC, cos = 1 Switching operations (x 103) 5, 000 250 VAC, cos = 0. 4 24 VDC, L/R = 7 ms 1, 000 500 200 1, 000 500 200 Load current (A) Load current (A) Reference: A maximum current of 0. 5 A can be switched at 125 VDC (cos = 1). Maximum current of 0. 2 A can be switched if L/R is 7 ms. In both cases, a life of 100, 000 operations can be expected. The minimum applicable load is 1 mA at 1 VDC (P reference value). H3YN-4-Z/-41-Z Switching operations (x 103) 5, 000 1, 000 500 250 VAC, resistive load 100 60 24 VDC, resistive load Load current (A) Reference: A maximum current of 0. 5 A can be switched at 125 VDC (cos = 1). Maximum current of 0. 2 A can be switched if L/R is 7 ms. In both cases, a life of 100, 000 operations can be expected. The minimum applicable load is 0. 1 mA at 1 VDC (P reference value). B-88 Solid-state Timer H3YN Connections H3YN-2/-21 DIN Indication H3YN-4/-41 H3YN-4-Z/-41-Z DIN Indication Timer circuit UP PW Timer circuit UP PW Pulse Operation A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing charts. H3YN-2/-21 Power (9-14) External short circuit (5-13) External input (9-13) Time limit contact NO (12-8) Timer circuit Time limit contact NC (12-4) Run/Power indicator (PW) Output indicator (UP) External input 50 ms min. Note: t: Set time Rt: Reset time H3YN-4/-41 H3YN-4-Z/-41-Z Power (9-14) External short circuit (5-13) External input (9-13) Time limit contact NO (10-6, 11-7, 12-8) Timer circuit Time limit contact NC (10-2, 11-3, 12-4) Run/Power indicator (PW) Output indicator (UP) 50 ms min. External input Note: t: Set time Rt: Reset time !Caution Be careful when connecting wires. Mode Pulse operation Power supply between 9 and 14 Short-circuit between 5 and 13 Input signal between 9 and 13 Power supply between 13 and 14 Terminals Operating mode; interval and all other modes Solid-state Timer H3YN B-89 Timers Connection Operation Timing Chart Operating mode H3YN-2/-21 Timing chart H3YN-4/-41 ON-delay Power (13-14) Power Time limit contact NC (9-1, 12-4) Output Time limit contact NO (9-5, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Interval Power Power (13-14) Time limit contact NC (9-1, 12-4) Output Time limit contact NO (9-5, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Flicker OFF-start Power (13-14) Power Time limit contact NC (9-1, 12-4) Time limit contact NO (9-5, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Output Flicker ON-start Power Output Power (13-14) Time limit contact NC (9-1, 12-4) Time limit contact NO (9-5, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Note: t: Set time Rt: Reset time B-90 Solid-state Timer H3YN DIP Switch Settings The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Timers 1s 10 s 1 min 10 min Time Ranges Model H3YN-2, H3YN-4 H3YN-4-Z Time range 1s 10 s 1 min 10 min H3YN-21, H3YN-41 H3YN-41-Z 1 min 10 min 1h 10 h Time setting range 0. 1 to 1 s 1 to 10 s 0. 1 to 1 min 1 to 10 min 0. 1 to 1 min 1 to 10 min 0. 1 to 1 h 1 to 10 h Setting Factory-set Yes No No No Yes No No No Note: The top two DIP switch pins are used to select the time ranges. Operating Modes Operating mode ON-delay Interval Flicker OFF-start Flicker ON-start Setting Factory-set Yes No No No Note: The bottom two DIP switch pins are used to select the operating mode. Nomenclature Output Indicator (Orange) (Lit: Output ON) Main Dial Set the desired time according to time range selectable by DIP switch. Run/Power Indicator (Green) (Lit: Power ON) Solid-state Timer H3YN B-91 Dimensions Note: All units are in millimeters unless otherwise indicated. Timers H3YN-2/-21 Front Mounting Eight, 3 × 1. 2 elliptic holes 28 max. 6. 4 (63. 0) 21. 5 max. H3YN-4/-41 Front Mounting H3YN-4-Z/-41-Z Fourteen, 3 × 1. 2 elliptic holes 28 max. 21. 5 max. Mounting Height PYF08A/PYF08A-N/PYF08A-E (PYF14A/PYF14A-N/PYF14A-E (see note)) PY08 (PY14 (see note)) PY08QN (PY14QN (see note)) H3YN Series H3YN Series H3YN Series PY08 (PY14) PYF08A (PYF14A) PY08QN (PY14QN) Note: Models in parentheses are Connecting Sockets to the H3YN-4/-41 or H3YN-4-Z/-41-Z. B-92 Solid-state Timer H3YN Accessories (Order Separately) Connecting Sockets Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3YN. When ordering any one of these Sockets, replace "@" with "08" or "14. " Timers Track Mounting/Front Connecting Sockets PYF08A Two, 4. 2 × 5 mounting holes 6 Eight, M3 × 8 sems 3. 4 Terminal Arrangement (Top View) Mounting Holes Two, 4. 5 dia. M4 or M3 72 max. 35. 4 59±0. 3 H3YN Series 90. 5 86. 6 4 6 23 max. 16. 5 30 max. PYF@A 15±0. 2 PYF-14A Two, 4. 2 × 5 mounting holes 6 Fourteen, M3 × 8 sems 3. 4 Terminal Arrangement (Top View) Mounting Holes Two, 4. 5 dia. M4 or M3 72 max. 35. 4 59±0. 3 4 29. 5 max. 6 16. 5 30 max. 22±0. 2 PYF-08A-N Terminal Arrangement 4 42 8 44 1 12 5 14 Mounting Holes (for Surface Mounting) 42 4 44 8 12 1 14 5 66. 5 max. 3. 6 dia. A2 A2 A1 12 41 9 11 14 14 13 14 14 13 A2 A2 A1 30 max. [. . . ] Do not set to the minimum setting in the flicker modes, otherwise the contact may become damaged. Be careful not to apply any voltage to the terminal screws on the back of the Timer. Mount the product so that the screws will not come in contact with the panel or metal parts. Do not use the H3YN in places where there is excessive dust, corrosive gas, or direct sunlight. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3YN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H3YN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag