User manual OMRON H7CX-N DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H7CX-N. We hope that this OMRON H7CX-N user guide will be useful to you.

Lastmanuals help download the user guide OMRON H7CX-N.


Mode d'emploi OMRON H7CX-N
Download
Manual abstract: user guide OMRON H7CX-NDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] New Product Multifunction Counter/Tachometer H7CX-@-N Ultra-compact Counter Provides More Complete Functionality. Basic Features · Short body with depth of only 59 mm (for 12 to 24-VDC Models with Screw Terminals). *1 · Better readability with character height of 12 mm on 4-digit models and 10 mm on 6-digit models. · The present value display characters can be switched between red, green, and orange. *2 Safety and Reliability · New set value limit and counter functions have been added. Other Features · Front Panel can be changed to white or light gray. *3 · Models with two independent tachometer inputs have been added to the series. *1. For 100 to 240-VAC Models with Screw Terminals: 78 mm, Models with Sockets: 63. 7 mm (case dimension). *2. The H7CX-A11 and H7CX-R11 have only red characters. *3. The Front Panel can be replaced with an optional Front Panel (except for Tachometer-only Models). [. . . ] Key protect level (KYPT) · Set the key protect level using the U Key. kp-1 (KP-1) kp-2 (KP-2) kp-3 (KP-3) kp-4 (KP-4) kp-5 (KP-5) kp-6 (KP-6) kp-7 (KP-7) Pulse cycle measurement/ pulse width measurement (CALM) · Set pulse cycle measurement or pulse width measurement using the U Key. phas (Pulse cycle (Pulse width measurement) measurement) *2 Set each digit using the individual U Keys. Output 1 (OUT1) ON count alarm set value Display unit (UNIT) · Set the display unit using the U Key. hz s (Hz) (s) Note: Displayed only when pulse cycle measurement is used. (0 × 1000 times) (9999 × 1000 times) 0 9999 Measurement interval (INTV) · Set each digit using the individual U Key. 200ms cont (200 ms) (Cont (10 ms min. )) Output 2 (OUT2) ON count alarm set value (0 × 1000 times) (9999 × 1000 times) 0 9999 *2 Note: Displayed only if the measurement speed is 10 kHz when pulse cycle measurement is used. Output ON count alarm set value/monitor value Output 1 (OUT1) ON count monitor value Note: The monitor value is only displayed. It cannot be set. Output 2 (OUT2) ON Note: The monitor value is only count displayed. monitor value 29 H7CX-A@-N Tachometer Explanation of Functions Tachometer Operation Items marked with stars can be set using the DIP switch. Tachometer Input Mode (tinm) Set the count input mode to one of the following: 1 input (F1), 2 inputs (F2), error (F3), absolute ratio (F4), or error ratio (F5). Input mode 1 input 2 inputs Input Count 1 Internal processing None Application Operation with only one input. Measuring the difference between two inputs (error in number of revolutions). Measuring the ratio of two inputs (ratio of number of revolutions). Measuring the ratio of error for two inputs (measuring the error ratio of number of revolutions). N: Number of pulses per revolution d: Diameter of rotating body (m) d: Circumference (m) d: Diameter of rotating body (m) Counts 1 and 2 None Count 1 input - Count 2 input Count 1 input ÷ Count 2 input Error Counts 1 and 2 · Observe the following points when setting a prescale value. Set the set value to a value less than {Maximum countable value - Prescale value}. Example: If the prescale value is 1. 25 and the counting range is 0. 000 to 999. 999, set the set value to a value less than 998. 749 (= 999. 999 - 1. 25). If the set value is set to a value greater than this, output will not turn ON. * Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF}. Absolute ratio Counts 1 and 2 (Count 1 input - Error ratio Counts 1 and 2 Count 2 input) ÷ Count 2 input Note: If the prescale value setting is incorrect, a counting error will occur. Check that the settings are correct before using this function. Averaging Method (avgt) (Only for Tachometer Operation) A simple average or moving average can be selected for the averaging. With the moving average method, the average of the measurement values is displayed each sampling cycle, in contrast to a simple average, with which the the average of the set number of samples is displayed. Tachometer Output Mode (totm) Set the output method for control output based on the comparison value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI-HI), and lower limit (LO-LO) can be set. (For details on the output modes, refer to Output Mode Settings and Operation on page page 34. ) Number of Averaging Times (avgn) Flickering display and output chattering can be prevented using average processing. Average processing can be set to one of four levels: no average processing, 2 times (i. e. , the average of 2 measurement values), 4 times, 8 times, or 16 times. The measurement cycle will be equal to the sampling cycle multiplied by the average processing setting (i. e. , the number of times). Average processing enables stable displays even for fluctuating input signals. Set the optimum number of times for the application. Counting Speed (cnts) Set the maximum counting speed (30 Hz/10 kHz) for CP1 input. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for this setting. Decimal Point Position (dp) Decide the decimal point position for the measurement value, OUT1 set value, and OUT2 set value. Prescale Value (pscl) It is possible to display the rate of rotation or the speed of a device or machine to which the H7CX is mounted by converting input pulses to a desired unit. If this prescaling function is not used, the input frequency (Hz) will be displayed. It is also possible to specify time (seconds) as the display value. [. . . ] The EEPROM is written at the following times: · When the power supply is turned OFF · When switching from Configuration Selection Mode or Function Setting Mode to Run Mode · Dispose of the product according to local ordinances as they apply. 53 MEMO 54 Warranty and Application Considerations Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H7CX-N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H7CX-N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag