Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H7GP. We hope that this OMRON H7GP user guide will be useful to you.
Lastmanuals help download the user guide OMRON H7GP.
Detailed instructions for use are in the User's Guide.
[. . . ] Total Counter/Time Counter
H7GP/H7HP
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 20), and Safety Precautions (page 15).
High-visibility, IP66/NEMA4 Protection Total Counter/Time Counter Range
· IP66 (JEM standard IP66G: oil resistance) and NEMA4 protection standards. · Switch between NPN and PNP operation. [. . . ] 106 g
Approved standards Case color Weight
10
Total Counter/Time Counter (DIN 72 x 36) H7HP
Connections
Terminal Arrangement
Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs. Non-contact input is also available.
AC Models
H7HP-A
100 to 240 VAC External power supply 12 VDC 50 mA max.
H7HP-C8
100 to 240 VAC External power supply 12 VDC 50 mA max.
Power supply
Power supply
Unused Unused Unused
0V
12 VDC
Power supply
Power supply
Unused Unused Unused
0V
12 VDC
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
Count 1 Count 2 input or input or start input gate input
Count 1 Count 2 input input
NPN mode PNP mode
NPN mode PNP mode
DC Models
H7HP-AD
12 to 24 VDC
H7HP-C8D
12 to 24 VDC
0V
Power supply
Unused Unused Unused Unused Unused
0V
Power supply
Unused Unused Unused Unused Unused
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
Count 1 Count 2 input or input or start input gate input
Count 1 Count 2 input input
NPN mode PNP mode NPN mode PNP mode
Operation
DIP Switch Settings
Switches 1 to 4 are all set to OFF before shipping.
H7HP-C8/-C8D
Pin no. 1 2 Item Unused Counting speed Unused --30 Hz --OFF --5 kHz PNP --ON
H7HP-A/-AD
Pin no. 1 2 3 4 Item Function Counting speed Time range Unused 30 Hz 99999. 9 h --OFF Total counter 5 kHz 99 h 59 min 59 s PNP --ON Time counter
3 4
Input mode (note) NPN
Note: When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on.
Input mode (note) NPN
Total Counter/Time Counter (DIN 72 x 36)
H7HP
11
Operating Modes
Total Counters
Reset input AC (10-2) DC (5-2) CP1 AC (10-3) DC (5-3) CP2 AC (10-4) DC (5-4) 999999 (see note)
Display
0
-99999 (see note) display
Note: Display values are shown for a 6-digit model. The count value will return to "0" when "999999" is exceeded.
Time Counters
Reset input AC (10-2) DC (5-2) Gate input AC (10-4) DC (5-4) Start input AC (10-3) DC (5-3) 99999. 9h (see note 1)
Display 0. 0 h
Note: 1. Display values are shown for full scale set to 99999. 9 h. The count value will return to "0" when "99999. 9" is exceeded. Gate input is available only when H7HP-A settings are made.
Nomenclature
2
(The figure shows the DIP switch label stuck to the rear of the case. )
1
3
1. Reset Key Resets the count value, but will not operate while the keys are protected. Key Protection Indicator Lit while the keys are protected (Reset Key is disabled. ). Refer to DIP Switch Settings for details.
12
Total Counter/Time Counter (DIN 72 x 36) H7HP
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7HP-A H7HP-C8
M3. 5 terminal screw
Terminal cover (provided)
Panel Cutouts Panel cutouts are as shown below (according to DIN43700).
Note: 1. The mounting panel thickness should be 1 to 6 mm. Water resistance will be lost if Counters are mounted side-by-side.
With Flush Mounting Bracket
Y92S-33 rubber packing (provided) Panel Y92F-33 flush mounting adaptor (provided)
Total Counter/Time Counter (DIN 72 x 36)
H7HP
13
Connections (Common)
Input Connections
Note: The undermentioned is common for all H7GP/H7HP models.
No-voltage Input (NPN Input Mode)
Reset, Count 1, Count 2, Start, and Gate Inputs
Open Collector Output
H7GP/H7HP
Voltage Output
12 VDC (12 to 24 VDC)
Sensor
12 VDC (12 to 24 VDC)
Sensor
12 VDC (12 to 24 VDC)
Reset, Count 1, Count 2, Start, and Gate Inputs Specification
Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage: 2 VDC max. Current flow for 0- short-circuit: Approx. Note: Two-wired sensors cannot be used.
Reset input Count 1 input Count 2 input Start input Gate input
0V
Reset input Count 1 input Count 2 input Start input Gate input
0V
Key Protection Input
Open Collector Output
H7GP/H7HP
Voltage Output
12 VDC (12 to 24 VDC)
Sensor
Sensor
12 VDC (12 to 24 VDC)
Key Protection Inputs Specification
Short-circuit (ON) impedance: Short-circuit (ON) residual voltage: Current flow for 0- short-circuit: Open (OFF) impedance: 1 k max. 0. 5 mA 100 k min.
Key protection input
0V
Key protection input
0V
Note: Two-wired sensors cannot be used.
Voltage Input (PNP Input Mode)
Reset, Count 1, Count 2, Start, and Gate Inputs
Sensor
12 VDC (12 to 24 VDC)
Reset, Count 1, Count 2, Start, and Gate Inputs Specification
Short-circuit (ON) impedance: 1 k max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Note: Two-wired sensors cannot be used.
Reset input Count 1 input Count 2 input Start input Gate input
0V
14
Total Counter/Time Counter H7GP/H7HP
Safety Precautions (Common)
Note: The undermentioned is common for all H7GP/H7HP models.
!CAUTION
This may occasionally cause electric shock, fire, or malfunction. Never disassemble, repair, or modify the H7GP/H7HP. [. . . ] If the power supply voltage is not reached quickly enough, the H7GP/H7HP may malfunction or outputs may be unstable.
Total Counter/Time Counter
H7GP/H7HP
15
Precaution for Correct Use
Power Supplies
When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately.
Power supply ON OFF
200 ms 0 to 90 ms 5 ms Impossible Unstable Possible
0 to 2 s
Input
Unstable Impossible
Self-diagnostic Function
The following displays will appear if an error occurs. (H7HP, 6-digit model) 99999999 max. (H7HP, 8-digit model) CPU Memory Correction Press RST Key or reset input
e1 e2
Press RST Key or turn power OFF and then ON
Labels
Unit labels are included with the H7GP/H7HP and DIP switch labels are included with the H7HP. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H7GP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H7GP will begin.