Manual abstract: user guide OMRON H8GNV1.02

Detailed instructions for use are in the User's Guide.

[. . . ] Preset Counter/Timer H8GN 1/32-mm DIN with Communications · Only 48 x 24 x 83 mm (W x H x D) · Switch between 4-digit preset counter and 4-digit timer operation. · While using the preset counter, it is possible to switch the display to monitor the totalizing count value (8 digits). · Built-in prescaling for counter operation. · ON/OFF-duty adjustable flicker mode that can be used to perform cyclic control is available for timer operation. [. . . ] The values displayed will be determined by the settings for Counter/Timer selection, time range, timer mode, and decimal point position made in the initial setting level. Press the Key to reset the present value. 2. SV 0 to 3 (sp-0, sp-1, sp-2, sp-3) SV 0 to 3 is displayed only when "SV-bank used" in the advanced function setting level has been set to ON. Used to set the set value when the SV-bank function is used. The operator can use the keys on the front to switch between the set values (SV 0 to 3). When the set value is changed in operation mode, the set value (SV 0 to 3) set in the adjustment level for SVbank will also change. 3. Totalizing Count Value The totalizing count value is displayed only if "totalizing counter used" in the advanced function setting level has been set to ON. The leftmost four digits of the 8-digit totalizing count value will be shown in No. 1 display and the rightmost four digits will be shown in No. Cycle Time (cyti) Cycle time is displayed only when the "output mode for timer function" in the initial setting level has been set to "Z. " Sets the cycle time used for ON/OFF-duty adjustable flicker mode (Z). Cyclic control can be performed easily in ON/OFF-duty adjustable flicker mode by first setting the cycle time in the adjustment level and by using the set value in operation level to change the ON-duty ratio. =Totalizing count value: 12, 345, 687 Press the Key to simultaneously reset the totalizing count value and the present value. Key during PV display Key during totalizing count value display PV 0123012012 Totalizing count value 0123345012 Refer to Input/Output Mode Settings on page page 79 for information on totalizing counter operation. Controlling the flowrate by opening and closing the electromagnetic valve by pulse control. Cycle time ON duty (%) Control output 4. SV-bank (m-sp) SV-bank is displayed only when "SV-bank used" in the advanced function setting level has been set to ON. To use the SV-bank function, the four set values (SV 0 to 3) can be set beforehand in the adjustment level. The keys on the front of the Unit can then be used during operation to switch between the set values. For models with built-in communications, communications can be used to switch between the set values. Switch between SV Cycle time passed ON duty can be changed like an analog input by using the Up and Down Keys. SV Refer to Input/Output Mode Settings on page 80 for information on ON/OFF-duty adjustable flicker mode operation. Preset Counter/Timer H8GN C-71 Initial Setting Level (1) Counter/Timer selection (2) Input mode (3) Time range 6. Output Mode for Timer Function (outm) The output mode is displayed only when "Counter/Timer selection" in the initial setting level has been set to counter. When the H8GN is to be used as a timer, set the output mode. Refer to Input/Output Mode Settings on page 79 for information on output mode operations. 7. Output Time (otim) The output time is displayed only when "output mode for counter function" in the initial setting level has been set to C or K or when "output mode for timer function" in the initial setting level has been set to A or B. When using one-shot output in the H8GN, set the output time for the one-shot output (0. 01 to 99. 99 s). One-shot output can be used only when the C or K output mode is selected for counter function or A or B output mode is selected for timer function. If the output time is set to "0" when selecting timer function, the output will be held. [. . . ] · The totalizing count range is 0 to 99, 999, 999. If the totalizing count exceeds 99, 999, 999, the count returns to 0. If the count drops below 0, it becomes 99, 999, 999. Totalizing count value Preset Counter/Timer H8GN C-79 Counters 9999 Timer Function A mode: Signal ON-delay (See note. ) Power supply Start Gate Power supply B mode: Flicker (See note. ) Start Gate Reset Control output Timer display SV UP 0 SV DOWN 0 Reset Control output Timer display SV UP 0 SV DOWN 0 D mode: Signal OFF-delay Power supply Start Gate Reset Control output Timer display Timer display SV UP DOWN 0 SV 0 Power supply E mode: Interval Start Gate Reset Control output SV 0 SV DOWN 0 UP F mode: Accumulative Power supply Start Gate Gate Reset Reset Control output Timer display SV 0 SV DOWN 0 Timer display UP Control output Cycle time ON duty setting (%) ON time Z mode: ON/OFF-duty adjustable flicker Power supply Start UP 0 Cycle time ON duty setting (%) ON time DOWN 0 Note: One-shot output or HOLD output can be selected for output: Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H8GN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H8GN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag