User manual OMRON J7MN DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON J7MN. We hope that this OMRON J7MN user guide will be useful to you.

Lastmanuals help download the user guide OMRON J7MN.


Mode d'emploi OMRON J7MN
Download
Manual abstract: user guide OMRON J7MNDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] contact + release J77MN-PFC-3R Door-coupling rotary The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and an extension shaft (5 mm x 5 mm, lenght 330 mm). The door-coupling rotary operating mechanisms are designed for degree of protection IP 65. The door locking device prevents accidental opening of the cubicle door in the ON position of the circuit-breaker. The OFF position can be locked with up to 3 padlocks. [. . . ] rated operational current Ie) Permissible ambient temperature Storage/transport Operation Storage/transport Operation Rated insulation voltage Ui Rated impulse withstand voltage Uimp Rated operational voltage Ue Rated frequency Utilization category Class Power loss Pv per circuit-breaker dependent on rated current In (upper setting range) R per conducting path = P/I² × 3 IEC 60 947-2 (circuit-breaker) IEC 60 947-4-1 (motor starter) acc. Type Switching capacity Ue Ie/AC-15 Ie/AC-12 Ith Ue L/R 200 ms Ie/DC-13 Ue Ie/AC-15 Ie/AC-12 Ith Rated operational voltage Rated operational current J77MN-U Undervoltage release Power consumption Response voltage J77MN-S Shunt release Power consumption Response voltage Short-circuit protection for auxiliary and control circuits Fuse gL/gG Miniature circuit breaker C-characteristic Conductor cross-sections for auxiliary and control circuits solid flexible solid AWG flexible AWG Ue L/R 200 ms Ie/DC-13 during pick-up uninterrupted duty trip pick-up during pick-up uninterrupted duty trip Control voltage 24 VAC 3A 5A 24 VDC 1A 24 VAC 6A 10 A 24 VDC 2A 8. 5 VA / 6 W 3 VA / 1. 2 W 0. 7 to 0. 35 × Us (V) 0. 85 to 1. 1 × Us (V) 8. 5 VA / 6 W 3 VA / 1. 2 W 0. 7 to 1. 1 × Us (V) 10 A 6A Screw-type Pz2 1 x (0. 5 to 2. 5) / 2x (0. 5 to 2. 5) mm² 1 x (0. 5 to 4) / 2 x (0. 75 to 2. 5) mm² 1 x (20 to 14) / 2 x (20 to 14) AWG 1 x (20 to 10) / 2 x (18 to 14) AWG 220 VDC 0. 25 A 240 VAC 2A 5A 220 VDC 0. 1 A 240 VAC 4A J77MN-11F / 20F / 02F & J7MN-T(A) Rated operational voltage Front transverse auxiliary switch with 1 Rated operational current NO + 1 NC, 2 NO, 2 NC Rated operational voltage Rated operational current J77MN-11S / 20S / 02S Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC & two signalling switches with 1 NO + 1 NC Rated operational voltage Rated operational current Time/Current characteristic J7MN-3P & J7MN-3R J7MN-6R & J7MN-9R Hour Minute Operation time Second Operation time Ir=10. 4, . . . , 15. 6 X In Second Minute Hour Ir=10. 4, . . . , 15. 6 X In Reflex tripping: t5 ms Reflex tripping: t5 ms Time Time Multiple of set current × Ie Multiple of set current × Ie I The curve shows the mean operating current at an ambient temperature of 20°C starting from cold. II The tripping characteristic of electromagnetic overcurrent releases (short-circuit releases) The tripping characteristic of the inverse-time delayed overload releases apply for DC and AC with a frequency of 0 to 400 Hz. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25 %. The characteristic shown here is a schematic representation of circuit-breakers for all ranges. Current limiting characteristics and I²t characteristics are available on request. I-8 Motor Protection Circuit Breaker J7MN Permissible ratings of devices approved for North America Circuit breakers J7MN as , , Manual Motor Starter" If used as , , Manual Motor Starter" the circuit breaker is always operated in combination with a short circuit device. For use with approbated fuses or circuit breakers according to UL489 or CSA22. 2 No. short-circuit current Ie 480 V 600 V J7MN-3R 240 V 480 V 600 V Motor load 1-phase Motor load 3-phase 115 V 230 V 200 V 230 V 460V 600V Max. breaker size 0. 16 0. 25 100 50 10 100 50 10 1 15 100 50 10 100 50 10 1 15 0. 4 0. 63 100 50 10 100 50 10 1 15 100 50 10 100 50 10 1 15 1 1 only. The sizes are selected according to National Electrical Code (UL), or Canadian Electrical Code (CSA) 1 100 50 10 100 50 10 /2 /2 3 15 1. 6 100 50 10 100 50 10 1 2. 5 100 50 10 100 50 10 1 1 1 4 100 50 5 100 50 10 1 1 3 6 100 25 5 100 50 10 1 1 8 100 25 5 100 50 10 1 10 50 10 5 100 50 10 1 13 50 10 5 100 50 10 1 17 40 10 5 100 30 10 1 3 3 5 10 15 60 60 22 30 10 5 100 30 10 11/2 3 5 7 1 /2 15 20 80 80 26 30 7. 5 5 100 30 10 2 5 7 1 /2 7 1 /2 15 20 100 100 32 A 20 kA 7. 5 kA 5 kA 100 kA 30 kA 10 kA 2 HP 5 HP 71/2 HP 10 HP 20 HP 30 HP 125 A 125 A J7MN-3P 240 V /8 /3 /4 1 2 3 /4 /2 1 /3 1 2 2 5 5 /2 2 3 5 /2 2 3 3 /10 1 3 /6 /2 /2 1 11/2 /3 /4 1 6 11/2 3 5 20 20 7 1 /2 10 50 50 11/2 10 15 10 40 40 15 15 30 30 15 J7MN-6R Rated operational current Max. short-circuit current Ie 240 V 480 V 600 V Motor load 1-phase Motor load 3-phase Max. breaker size 115 V 230 V 230 V 460V 600V 26 100 50 10 2 5 10 20 25 100 100 32 100 50 10 3 5 10 25 30 125 125 40 100 50 10 3 7 1 /2 15 40 150 150 50 100 50 10 5 10 15 50 200 200 63 100 50 10 5 15 20 50 60 250 250 J7MN-9R 63 100 25 10 5 15 25 50 60 250 250 75 100 25 10 7 1 /2 15 25 60 75 300 300 90 100 25 10 10 20 30 75 100 350 350 100 A 100 kA 25 kA 10 kA 10 HP 20 HP 40 HP 75 HP 100 HP 400 A 400 A Low voltage switch gear 30 401/2 Circuit breakers J7MN as "Combination Motor Controller Type E" and " Suitable for Group Installation" Acc to UL508 demands a line-side 1 inch air and 2 inch creepage distance for , , Combination Motor Controller Type E" is necessary. Therefor circuitbreaker J7MN-3R is approved to UL 508 in combination with the Terminal block J7MN-TB32. Circuit-breakers J7MN-9R J7MN-3R + J77MN-TB32 Rated operational current Max. short-circuit current Ie 240 V 480 V 600 V Motor load 1-phase Motor load 3-phase 115 V 230 V 200 V 230 V 460V 600V Max. rated fuse or breaker 0. 16 0. 25 100 50 10 500 100 50 10 500 0. 4 0. 63 100 50 10 500 100 50 10 500 1 1 are approved to UL 508 in combination with the insulation barriers J7MN-TB100. According to CSA these terminal blocks can be omitted when the device is used as "Combination Motor Controller Type E". 1 100 50 10 /2 /2 1. 6 100 50 10 1 2. 5 100 50 10 1 1 1 4 100 50 10 1 1 3 6 100 50 10 1 1 8 100 50 10 1 10 100 50 10 1 13 100 50 10 1 17 100 30 10 1 3 3 5 10 15 500 22 100 30 10 11/2 3 5 7 1 /2 15 20 500 26 100 30 10 2 5 7 1 /2 7 1 /2 15 20 500 32 A 100 kA 30 kA 10 kA 2 HP 5 HP 71/2 HP 10 HP 20 HP 30 HP 500 A /8 /3 /4 1 2 3 /4 /2 1 /3 1 2 2 5 5 /2 2 3 5 /2 2 3 3 /10 1 3 /6 /2 /2 1 11/2 /3 /4 1 11/2 3 5 500 7 1 /2 10 500 11/2 500 10 500 500 500 500 500 Motor Protection Circuit Breaker J7MN I-9 J7MN-6R Rated operational current Max. short-circuit current Ie 240 V 480 V 600 V Motor load 1-phase Motor load 3-phase Max. rated fuse or breaker 115 V 230 V 230 V 460V 600V 26 100 50 10 2 5 10 20 25 600 32 100 50 10 3 5 10 25 30 600 40 100 50 10 3 7 1 /2 15 30 40 600 50 100 50 10 5 10 15 40 50 600 63 100 50 10 5 15 20 50 60 J7MN-9R + J77MN-TB100 63 100 40 10 5 15 25 50 60 75 100 40 10 7 1 /2 15 25 60 75 90 100 40 10 10 20 30 75 100 100 A 100 kA 40 kA 10 kA 10 HP 20 HP 40 HP 75 HP 100 HP 600 1, 000 1, 000 1, 000 1, 000 A Combination Motor Controller Type E Ratings of auxiliary switches and alarm switches Breaking capacity Lateral auxiliary switch with J77MN-xxS and signalling switch J77MN-T A600 Q300 Transversal auxiliary switch with J77MN-xxF A300 R300 AC DC Descriptions Releases Circuit-breakers J7MN are equipped with bimetallic-based, inversetime delayed overload releases and with instantaneous overcurrent releases (electromagnetic short-circuit releases). The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value 13 times the rated current and thus enable trouble-free start-up of motors. The scale cover can be sealed to prevent unauthorized adjustments to the set current. [. . . ] Contact blocks J77MN-11F J77MN-20F J77MN-02F Aux. Contact Block (side mounted) J77MN-11S J77MN-20S J77MN-02S Alarm Switch J77MN-T-11S J77MN-TA-11S Undervoltage Release J77MN-U-. . . Shunt Release J77MN-S-. . . I-10 Motor Protection Circuit Breaker J7MN Dimensions Circuit-breaker J7MN-3P Height of arcing spaces (clearance from earthed parts ) at Ue (V) mm inch 240 20 0. 8 415 20 0. 8 460 20 0. 8 525 20 0. 8 690 20 0. 8 Circuit-breaker J7MN-3R Height of arcing spaces (clearance from earthed parts ) at Ue (V) mm inch 240 30 1. 18 415 30 1. 2 460 30 1. 18 525 30 1. 18 690 50 2 Circuit-breaker J7MN-6R Height of arcing spaces (clearance from earthed parts ) at Ue (V) mm inch 240 50 2 415 50 2 460 50 2 525 50 2 690 50 2 Circuit-breaker J7MN-9R Height of arcing spaces (clearance from earthed parts ) at Ue (V) mm inch 240 50 2 415 70 2¾ 460 70 2¾ 525 110 4, 33 690 150 6 All 1) 2) 3) 4) 5) Side aux. contact Magnetic trip alarm Shunt or undervoltage release of arcing Transverse aux. to EN 50022 3P/3R 6) Push-in Lugs for screw mounting 3R/6R/9R 7) Handle lock in OFF-position ( 5 mm) 9R 8) 4 mm hexagon socket screw 9) 70 mm DIN-rail acc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON J7MN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON J7MN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag