[. . . ] I558-E2-02-X
JX
Compact and complete Model: JX 200 V Class Three-Phase Input 0. 2 to 7. 5 kW 200 V Class Single-Phase Input 0. 2 to 2. 2 kW 400 V Class Three-Phase Input 0. 4 to 7. 5 kW
USER'S MANUAL
Introduction
Introduction
Thank you for choosing the general-purpose Inverter JX. This User's Manual (hereinafter called "this manual") describes the parameter setting methods required for installation/wiring and operation of the JX model, as well as troubleshooting and inspection methods. This manual should be delivered to the actual end user of the product. After reading this manual, keep it handy for future reference. [. . . ] A081 Function name AVR selection AVR voltage selection Data 00: Always ON 01: Always OFF 02: OFF during deceleration 200-V class: 200/215/220/230/240 400-V class: 380/400/415/440/460/480 d004, A001, A005 Default setting 02 Unit
A082
200/400
4
Related parameters
Functions
·With A081 (AVR selection), set whether to enable or disable this function. ·Note that the Inverter cannot output voltage beyond that of the incoming voltage. ·To avoid a possible overcurrent trip during deceleration, set the AVR selection to "Always ON" (A081: 00).
Parameter No. Data 00 01 Description Always ON Always OFF OFF during deceleration Note Enabled during acceleration, constant speed operation, and deceleration. Disabled during acceleration, constant speed operation, and deceleration. Disabled only during deceleration in order to reduce the energy regenerated to the Inverter by increasing the motor loss. This will avoid a possible trip due to regeneration during deceleration.
A081
02
Automatic Energy-saving Operation Function
This function automatically adjusts the Inverter output power to a minimum during constant speed operation. This is suitable for the load of reduced torque characteristics, such as a fan and pump.
Parameter No. A085 A086 Function name RUN mode selection Data 00: Normal operation 01: Energy-saving operation Default setting 00 50 Unit %
Energy-saving response/ 0 to 100% accuracy adjustment
·To operate with this function, set the RUN mode selection (A085) to 01. You can adjust the response and accuracy in the energy-saving response/accuracy adjustment (A086). ·Controls the output power at a comparatively slow rate. If rapid load fluctuation like impact load occur the motor may stall resulting in an overcurrent trip.
Parameter No. Data 0 A086 100 Fast Low Large Response Slow Accuracy High Energy-saving effect Small
4-26
4-2 Function Mode
2-step Acceleration/Deceleration Function
This function changes the acceleration/deceleration time during such operations.
Parameter No. A092
*
Function name Acceleration time 2 2nd acceleration time 2 Deceleration time 2 2nd deceleration time 2 2-step acceleration/ deceleration selection 0. 01 to 99. 99 100. 0 to 999. 9 1000. to 3000.
Data
Default setting 15. 0 15. 0 15. 0 15. 0 00
Unit s s s s
A292
A093
*
A293
A094
*
A294
A095
*
A295
A096
*
A296
00: Switched via multi-function input 09 (2CH) 01: Switched by setting 00: Switched via multi-function input 09 2nd 2-step acceleration/ (2CH) deceleration selection 01: Switched by setting 2-step acceleration 0. 0 to 400 frequency 2nd 2-step acceleration 0. 0 to 400 frequency 2-step deceleration 0. 0 to 400 frequency *2nd 2-step deceleration 0. 0 to 400 frequency Related parameters
4
00 0. 0 0. 0 0. 0 0. 0
Functions
Hz Hz Hz Hz
F002, F003, F202, F203, C001 to C005
* To switch to the 2nd control, allocate 08 (SET) to the multi-function input terminal and then turn it on. ·The acceleration/deceleration time can be switched via the multi-function input terminal or automatically with an arbitrary frequency. ·To switch via the multi-function input terminal, allocate 09 (2CH) to it. it
Data 09 Symbol 2CH Function name 2-step acceleration/deceleration OFF Status ON Description Enables the 2-step acceleration/ deceleration time. Disables the 2-step acceleration/ deceleration time.
Related parameters
Required settings (Example 1) When A094/A294 is set to 00
FW
C001 to C005 A094 = 00 (Example 2) When A094/A294 is set to 01
FW
2CH
Acceleration 2 Deceleration 2 Acceleration 2 A095/A295 Deceleration 1 Acceleration 1 Deceleration 1 A096/A296 Deceleration 2
Acceleration 1
Output frequency
Output frequency
F002/F202 A092/A292 A093/A293 F003/F203
F002/F202 A092/A292 A093/A293 F003/F203
4-27
4-2 Function Mode
Acceleration/Deceleration Pattern
This function is used when smooth acceleration/deceleration is needed.
Parameter No. A097 A098 Function name Acceleration pattern selection Deceleration pattern selection Data 00: Line 01: S-shape curve 00: Line 01: S-shape curve Default setting 00 00 Unit
·Acceleration/deceleration pattern can be set according to each system.
4
Parameter No. 00 Line
Set value 01 S-shape curve
Functions
A097 (Acceleration)
Output frequency
Output frequency
Time
Time
A098 (Deceleration)
Output frequency
Time
Output frequency
Time
Description
Accelerates/Decelerates linearly before reaching the set output frequency value.
Helps prevent the collapse of cargo on the elevating machine or conveyor.
External Frequency Adjustment Function (OI)
Parameter No. A101 A102 A103 A104 A105 Function name OI start frequency OI end frequency OI start ratio OI end ratio OI start selection Related parameters 0. 00 to 400. 0 0. 00 to 400. 0 0. 00: External start selection 01: 0 Hz Data Default setting 0. 0 0. 0 0. [. . . ] 0. 0 to 200. 0
1.
No
C074
00
No
C075
1
No
C076
Communication error selection
02
No
C077 C078 Various adjustment C081
Communication error timeout Communication wait time O adjustment
0. 00 0. 100. 0
No No Yes
s ms %
C082
OI adjustment
0. 0 to 200. 0
100. 0
Yes
%
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
App-16
Appendix-1 Parameter List
Parameter No. C086 C091 C101
Function name AM offset adjustment Not used UP/DWN selection
Monitor or data range (Digital Operator) 0. 0 to 10. 0 Use "00". 00: Do not store the frequency data 01: Store the frequency data 00: Trip reset at power-on 01: Trip reset when the power is OFF 02: Enabled only during trip (Reset when the power is ON. ) 00: RUN (signal during RUN) 01: FA1 (constant speed arrival signal) 02: FA2 (over set frequency arrival signal) 03: OL (overload warning) 04: OD (excessive PID deviation) 05: AL (alarm output) 06: Dc (disconnection detected) 07: FBV (PID FB status output) 08: NDc (network error) 10: ODc (Do not use. ) 43: LOC (light load detection signal) 00: AND 01: OR 02: XOR 0. 0 to 100. 0 0. 0 to 100. 0 0. 0 to 100. 0 0. 0 to 100. 0
Default setting 0. 0 00 00
Changes during operation Yes No
Unit
Set value
V
C102
Reset selection
00
No
C141
Logic operation function A input
00
No
Others
C142
Logic operation function B input
01
No
C143
Logic operator selection Output terminal 11 ON delay Output terminal 11 OFF delay Relay output ON delay Relay output OFF delay Motor capacity selection *2nd motor capacity selection Motor pole number selection *2nd motor pole number selection Stabilization parameter *2nd stabilization parameter
00
No
C144 C145 C148 C149
0. 0 0. 0 0. 0 0. 0 Factory default
No No No No
s s s s
H003
Control parameter
H203
200-V class 0. 2/0. 4/0. 75/1. 5/2. 2/3. 7/5. 5/7. 5 400-V class 0. 4/0. 75/1. 5/2. 2/3. 7/5. 5/7. 5 2 4 6 8
No Factory default 4 No 4 100 Yes Yes
kW
H004 H204 H006 H206
Pole
% %
0. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON JX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.