[. . . ] Pushbutton Switches
(1)
(2)
(3)
(4)
(5)
(5) Terminal Type Symbol
P S
M 1 6 5 - T R - 24D - P
(1) Degree of Protection Symbol No symbol
5
Terminal type PCB terminals Screw-Less Clamp
No symbol Solder terminals
Protection
IP40
(4) Light Source (2) Shape of Display Symbol
J A T 3J BA
(3) Color of Display Symbol
R G Y PY W A
Symbol 5 12 24 5D 12D 24D
Type
Operating voltage 5 VAC/VDC
Rated voltage 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC 5 VDC 12 VDC 24 VDC
IP65 oil-resistant
Shape Rectangular Square Round Rectangular (3-way guard) Square (24-mm square)
Color Red Green Yellow Pure yellow White Blue
Incandescent 12 VAC/VDC lamp 24 VAC/VDC 5 ±5% VDC LED 12 ±5% VDC 24 ±5% VDC Type LED Operating voltage 90 to 121 VAC/VDC
Voltage Reduction Unit (24-V Built-in LED) Symbol T1 T2 Rated voltage 110 VAC/VDC 220 VAC/VDC
180 to 242 VAC/VDC
Solder terminals are available only with 100-V models. The Voltage Reduction Unit is not available for models with PCB terminals.
Indicator
M16
G-127
Ordering Information
List of Models
Ordering as a Set
The model numbers used to order sets of Units are given in the following tables. One set comprises the Display, Case, Lamp, and Socket.
M16@-J (Rectangular) Models
Solder Terminal Models
Appearance Lighting LED without Voltage Reduction Unit Incandescent lamp Operating voltage 5 VDC 12 VDC 24 VDC 5 VDC/VAC 12 VDC/VAC 24 VDC/VAC IP40 M16-J@-5D M16-J@-12D M16-J@-24D M16-J@-5 M16-J@-12 M16-J@-24 IP65 oil-resistant M165-J@-5D M165-J@-12D M165-J@-24D M165-J@-5 M165-J@-12 M165-J@-24 Display color symbol (See note. ) R: red Y: yellow G: green A: blue W: white PY: Pure yellow
M16@-A (Square) Models
Solder Terminal Models
Appearance Lighting LED without Voltage Reduction Unit Incandescent lamp Operating voltage 5 VDC 12 VDC 24 VDC 5 VDC/VAC 12 VDC/VAC 24 VDC/VAC IP40 M16-A@-5D M16-A@-12D M16-A@-24D M16-A@-5 M16-A@-12 M16-A@-24 IP65 oil-resistant M165-A@-5D M165-A@-12D M165-A@-24D M165-A@-5 M165-A@-12 M165-A@-24 Display color symbol (See note. ) R: red Y: yellow G: green A: blue W: white PY: Pure yellow
M16@-T (Round) Models
Solder Terminal Models
Appearance Lighting LED without Voltage Reduction Unit Incandescent lamp Operating voltage 5 VDC 12 VDC 24 VDC 5 VDC/VAC 12 VDC/VAC 24 VDC/VAC Note: Enter the desired color symbol for the Display in @. [. . . ] Refer to page 134 for details of panel cutout dimensions.
Rectangular
M16-J
Solder terminals
Packing (t0. 5)
Square
M16-A
Solder terminals
Packing (t0. 5)
14. 6 dia. 1
Lamp terminals
Lamp terminals
Round
M16-T
Solder terminals
Mounting nut Lock ring Packing (t0. 5) M16 × 1
Mounting nut Lock ring
18 dia. 18 dia.
Lamp terminals
Terminal Hole Dimensions
Lamp terminals
14. 6 dia. 18 dia.
Mounting nut Lock ring
G-132
Indicator M16
Rectangular
M16@-P
PCB terminals
The rectangular model is given here as a representative example. Lamp terminals are provided even for non-lighting applications.
9. 5 6 28. 3 26. 4 23. 1 21. 1 10. 8 4 2. 5 18. 4 20. 4 6. 3 0. 5
Panel Cutouts
16+0. 2 dia. 0 24 min.
24 min.
Lock ring Mounting ring
18
15. 1 0. 5
4. 85 12. 4 18. 6
Recommended panel thickness: 0. 5 to 3. 2 mm
21 24
Packing (t0. 5) (for oil-resistant IP65 only)
Rectangular
M16@-T1, T2
Voltage-reduction lighting, solder terminals
Panel Cutouts
Direction-indication arrow 16+0. 2 0 dia. 25 min.
Display Case Packing (t0. 5) (for oil-resistant IP65 only) Marking face Lock ring Mounting ring Socket
23 min. (Dimension A)
Recommended panel thickness: 0. 5 to 3. 2 mm
Rectangular
M16@-S
Screw-Less Clamp
Socket dismounting lever
Lock ring Mounting ring
Packing (t0. 5) (for oil-resistant IP65 only)
Indicator
M16
G-133
Pushbutton Switches
Terminal Arrangement
Solder Terminals
Bottom View
Screw-Less Clamp
Black
Voltage-reduction Lighting
Bottom View
Side with TOP indicated
Bottom View
Side with TOP indicated
Note: The L+ is not shown on the Socket Unit. Red Note: Voltage-reduction lighting models with Screw-Less Clamps (A16L-@T1-2S, A16L-@T2-2S) incorporate voltage-reduction circuits.
Panel Cutouts
Solder Terminals
Solder Terminals
Rectangular M16@-J
(Top View)
16+0. 2 dia. 0 24 min.
Screw-Less Clamp
Square M16@-A Round M16@-T
(Top View)
16+0. 2 dia. 0
19 min.
Rectangular M16@-S
(Top View)
16+0. 2 dia. 0 25 min.
19 min.
19 min.
32 min. Make sure the thickness of the mounting panel is 0. 5 to 3. 2 mm. If, however, a Switch Guard or Dust Cover is used, the thickness of the mounting panel must be 0. 5 to 2 mm. If the panel is to be finished with coating, etc. , make sure that the panel meets the specified dimensions after coating.
Installation
Refer to the Installation section for the A16.
G-134
Indicator M16
Precautions
Refer to the Technical Information for Pushbutton Switches (Cat. A143) and the Precautions section for the A16.
Correct Use
Mounting
When mounting the Case onto the Socket Unit, ensure that the orientation is correct. [. . . ] After locking, pull on the wire gently to confirm that it is securely locked.
Removing Procedure
Remove wires by pulling them while pressing the release button. Note: When reusing wires that have already been locked, cut off the end of the wire and strip the wire again before using.
Indicator
M16
G-135
Pushbutton Switches
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON M16
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON M16 will begin.