[. . . ] Moreover, Safety I/O Terminals can be added to increase safety I/O capacity for distributed allocation through the network. DeviceNet wiring on the existing network can be used as is, facilitating efficient design by expanding on the existing system. The programmability of safety circuits, expandability of I/O using the network, and compatibility with the DeviceNet open network effects major changes to the framework of previous safety design systems.
Programmable Safety Circuits
DeviceNet Safety System
Safety I/O Can Be Expanded through the Network.
Compatible with DeviceNet Open Network
Safety
NE1A/DST1
D-1
Complies with the Highest Safety Standards in the world
The DeviceNet Safety System conforms to IEC 61508 SIL3 for functional safety, and EN 954-1 Category 4 for machine safety, complying with the world's highest level of safety standards. [. . . ] · Construct safety circuits easily with special Function Blocks. · Up to 128 Function Blocks can be used.
DeviceNet Safety Communications Functions
· Provides DeviceNet Safety Master functionality. Expand using up to sixteen Input Slaves with 12 points each (192 points total) and eight I/O Slaves with 16 points each (128 points total). · Safety Slave functionality is also included. Interlock control can be incorporated between Safety Network Controllers.
DeviceNet Slave Functionality
· Monitor safety I/O and status information from the DeviceNet Master.
DST1-series Safety I/O Terminals
Safety Input and Safety I/O Models Available
· Safety inputs: 12-point model (DST1-ID12SL-1) · Safety I/O: 8-point/8-point model (DST1-MD16SL-1) · Safety I/O: 4-point/4-point (relay outputs) model (DST1-MRD08SL-1)
DeviceNet Slave Functionality
· Safety I/O and status information can be allocated as a DeviceNet Slave. · Maintenance functions are provided for measuring the number of operations or the operating time for safety devices.
Easy Wiring
· Superior construction and preventive maintenance using clamp connectors.
WS02-CFSC1-E Safety Network Configurator
Network Configurator Functions
· Includes previous DeviceNet Configurator functions. · Performs setup for the DeviceNet Safety network configuration.
Programming Functions
· I/O configuration functions for Safety Network Controllers and Safety I/O Terminals. · Programming functions for safety circuits. · Monitor programs.
D-2
DeviceNet Safety System
Stand-Alone Programmable Controller
Programmable Safety Circuits
Until now, safety design involved combining safety relays to configure safety control circuits. This process involved tedious wiring, and moreover, any changes required direct modification of the wiring. The DeviceNet Safety System uses programmable safety circuits, dramatically improving the ease of design and modification.
Previous Safety Control Circuits
Programmable Safety Circuits
Emergency Stop Pushbutton Switch Contactor Safety Door Switch Safety Relay Unit Safety Relay Unit
Safety Door Switch
USB Safety Network Controller Emergency Stop Pushbutton Switch Safety Relay Unit Contactor
Safety Network Configurator
Safety logic operations can be programmed using Function Blocks.
Motor
Contactor
Contactor
Motor
System Configuration 1
Configuration Example for High-speed Safety I/O Response Using Small Number of Points NE1A-SCPU01 WS02-CFSC1-E
NE1A-SCPU01 Safety Network Controller
USB
WS02-CFSC1-E Safety Network Configurator
Delivers high-speed I/O response in a single Unit with up to 16 safety inputs and 8 safety outputs.
Emergency Safety Door Stop Pushbutton Switch Switch
Contactor
NE1A/DST1
D-3
Safety Network
Expand Safety I/O Through Networks
Safety components distributed over many different installation locations required long and complicated wiring. Replacing the wiring with a network between safety components greatly improves productivity
Previous Machine Connections
Connecting Devices Using DeviceNet Safety By using Safety I/O Terminals, safety I/O can be expanded easily through the network.
Safety Network Controller Safety Network Controller
Safety control
DeviceNet Safety
Safety I/O Terminal
Safety I/O Terminal
Safety I/O Terminal
Safety Contactor Door Switch Safety Light Curtain
Contactor
Emergency Contactor Stop Pushbutton Switch Safety Light Curtain
Safety Door Switch Contactor Contactor Emergency Stop Pushbutton Switch Contactor
Expand a Safety Network Controller using up to sixteen Input Slaves with 12 points each (192 points total), and up to eight I/O Slaves with 16 points each (128 points total).
System Configuration 2
Example of Safety I/O Configuration for Distributed Hazard Sources NE1A-SCPU01 DST1 Series WS02-CFSC1-E Distributed allocation of safety I/O devices can be achieved easily using Safety I/O Terminals and the DeviceNet Safety Network.
NE1A-SCPU01 Safety Network Controller NE1A-SCPU01 Safety Network Controller USB
WS02-CFSC1-E Safety Network Configurator
DeviceNet Safety
DST1-ID12SL-1 Safety I/O Terminal DST1-MRD08SL-1 Safety I/O Terminal
DST1-MD16SL-1 Safety I/O Terminal
D-4
DeviceNet Safety System
Combined Safety / DeviceNet Network
Compatible with the DeviceNet Open Network
Linking machine control is indispensable for achieving total control. By linking to machine control data, safety control can be monitored from the PLC, enabling the location of an error to be identified in an instant and improving maintenance. DeviceNet Safety System utilizes the DeviceNet wiring from the existing network as is.
Machine control
NS-series Programmable Terminal
Safety control
Safety Network Controller with Safety interface. Network system settings and Safety Network Controller programming.
Safety Network Controller
Safety Network Configurator
DeviceNet Master
USB
Incorporating DeviceNet Slave functionality. Monitor safety I/O and status information from the DeviceNet Master directly without requiring a gateway or other interface.
SYSMAC CJ-series PLC
DeviceNet Safety Master
DeviceNet
DeviceNet Slave DeviceNet Safety Slave
Safety I/O Terminal Analog I/O Terminal Remote I/O Terminal Safety I/O Terminal
Includes functions for improving maintenance.
System Configuration 3
Machine Control Safety Control
NE1A-SCPU01 Safety Network Controller
System Configuration Example for Total Control of Machine Control and Safety Control SYSMAC CJ Series NE1A-SCPU01 DST1 Series WS02-CFSC1-E The DeviceNet Network can be used to monitor the status of safety I/O and safety circuits on the DeviceNet Safety Network from existing DeviceNet Masters or other PLCs.
SYSMAC CJ-series PLC
DeviceNet Master
DeviceNet
DeviceNet Safety Master
DeviceNet Slave
DeviceNet Safety Slave
DST1-ID12SL-1 Safety I/O Terminal Analog I/O Terminal Remote I/O Terminal DST1-MRD08SL-1 Safety I/O Terminal
NE1A/DST1
D-5
Ordering Information
Safety I/O Terminals
Appearance Appearance Description Part Number
Safety Network Controller
16 PNP Inputs 8 PNP Outputs 4 Test Outputs 128 Function Block Programming Removable Cage Clamp Terminals
NE1A-SCPU01
IP20 Safety I/O Terminals
Appearance Appearance Description Part Number
Input Terminal
12 PNP Inputs 4 Test Outputs Removable Cage Clamp Terminals
DST1-ID12SL-1
Mixed I/O Terminal
8 PNP Inputs 8 PNP Outputs 4 Test Outputs Removable Cage Clamp Terminals DST1-MD16SL-1
Mixed I/O Terminal
4 PNP Inputs 4 relay Outputs (4 x 2-single pole) 4 Test Outputs Removable Cage Clamp Terminals
DST1-MRD08SL-1
Software
Appearance Appearance Description Part Number
Safety Network Configurator
Installation Disk (CD-ROM) IBM PC/AT Compatible Windows 2000 or XP
WS02-CFSC1-E (English Version)
D-6
DeviceNet Safety System
Specifications
NE1A-SCPU01 General Specifications
DeviceNet communications 11 to 25 VDC (supplied from communications power supply voltage connector) Unit power supply voltage I/O power supply voltage 20. 4 to 26. 4 VDC (24 VDC 15% +10%)
Safety Output Specifications
Output type Rated output current Residual voltage Leakage current Sourcing outputs (PNP) 0. 5 A max. [. . . ] available space Display functionality of S-VGA monitor or higher One CD-ROM drive min. Either of the following communications ports is required. · USB port: For online communications via SNC USB port (USB1. 1) · DeviceNet Interface Card (3G8E2DRM21-EV1): For online communications via DeviceNet.
Manuals
Description Reference Number Devicenet Safety Network ControlZ906 ler Operation Manual Devicenet Safety DST1-series Safety I/O Terminals Operation Manual Z904
Devicenet Safety System ConfiguZ905 ration Manual
Communications port
Note: Windows is a registered trademark of Microsoft. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON NE1A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON NE1A will begin.