[. . . ] V233-E1-05
NSA-Series
Industrial PC
USER´S MANUAL
NSA-Series Industrial PC
NSA12/15-TX01B NSA12/15-TX01S NSA12/15-TX01B-E NSA12/15-TX01S-E NSA15-TX01B-01E NSA15-TX01S-01E
User's Manual
iv
Introduction
The NSA-series Industrial PC is an industrial, panel-mountable computer equipped with a Celeron M Processor and featuring a touch panel and display. Be sure to read and understand the functions and performance specifications in this manual prior to using it, and operate it as described herein.
Intended Audience
This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). · Personnel in charge of introducing FA systems into production facilities · Personnel in charge of designing FA systems · Personnel in charge of managing FA systems and facilities
Notice
This manual provides information for connecting and setting up an NSA-series Industrial PC. Be sure to read this manual before attempting to use it, and keep the manual close at hand for reference during operation.
OMRON, 2006
All rights reserved. [. . . ] Connect a PS/2 keyboard and mouse or a USB keyboard and mouse to the NSA-series Industrial PC before calibrating the touch panel. Make sure the keyboard and mouse are properly connected.
Note Shut down the NSA-series Industrial PC operating system and turn OFF the NSA-series Industrial PC before you connect the PS/2 keyboard and mouse.
3
Installing the NSA-series Industrial PC and Connecting Peripheral Devices
2. Start up the NSA-series Industrial PC and select Start Programs UPDD Settings from the bottom left corner of the screen to launch the settings program.
Settings
3. Click the Calibration Tab on the Pointer Device Properties Menu, then click the Calibrate Button.
Calibrate Button
Make sure the EEPROM Calibration box is selected.
3-18
3-5
Adjusting the Touch Panel and Display
3-5-1 Calibrating the Touch Panel
4. Touch the tip of the arrow on the touch panel screen. When that calibration point is entered, an arrow will appear in another location. Touch the tip of the each arrow that appears.
Touch the tip of the arrow to input a calibration point.
3
Installing the NSA-series Industrial PC and Connecting Peripheral Devices
5. After all the calibration points have been entered, the Check calibration dialog box will appear. A message will be displayed prompting you to save the calibration data. If there were no problems with the calibration points, press the OK Button or the Enter Key on the keyboard. If there was a problem with a calibration point, do not touch anything for 10 seconds. The calibration data will be discarded and will not be saved.
OK Button
Note
The touch panel may deviate from its coordinates over time. We recommend that you recalibrate the touch panel whenever that occurs.
Note
The calibration data is stored on the EEPROM in the NSA-series Industrial PC. If the EEPROM calibration box is not checked, the calibration data will be stored in Windows.
3-19
Adjusting the Touch Panel and Display
3
Installing the NSA-series Industrial PC and Connecting Peripheral Devices
3-20
3-5
Section 4 RAS Functions
4-1
RAS Function Details
4-1-1 What Is the RAS Solution for OMRON Industrial PCs?
4-1 RAS Function Details
NSA-series Industrial PCs are equipped with standard PC RAS functions and other unique RAS functions that can be used to construct highly reliable systems.
4-1-1 What Is the RAS Solution for OMRON Industrial PCs?
RAS functions have important roles in various business scenes using industrial PCs, where high reliability of a PC is required, as well as advanced features and high performance. The OMRON RAS Solution is a comprehensive capability to constantly monitor the system status and send information on any detected error to users and the system. RAS functions can shutdown and/or enable the system to recover safely. An OMRON Industrial PC embedded with a specific RAS Board can greatly enhance reliability through a RAS system that combines RAS Middleware and a RAS Utility. The RAS system in an OMRON Industrial PC provides main the following functions: · A Monitoring Function is provided to constantly monitor the hardware and software of the industrial PC and provide the user failure notification when an error is detected or a failure occurs. · An Auto-recovery Function forcefully shuts down the system when a failure occurs to prevent further faults and reboot the system for recovery. · A Logging Function saves events in operating the industrial PC (such as power supply ON/OFF events, OS startup/shutdown events, etc. ), system status when a failure occurs, and conditions of the motherboard (i. e. , the temperature and power supply) in RAS Board memory backed up by a battery. · The Log Analysis Function analyzes the cause and/or tendency of failures using large amounts of log data saved in memory.
4
RAS Functions
4-1-2 Monitoring and Auto-recovery
Monitoring Functions
The RAS functions enable users to monitor operation status and detect failures. The Industrial PC provides the following monitoring functions. [. . . ] @ Cables for connecting the CPU Box and the Touch Panel. Memory Card with Japanese Windows XP Embedded Version installed in advance Memory Card with English Windows XP Embedded Version installed in advance Sheet to protect the display from reflection. Application Replacement battery for motherboard and RAS board.
Memory Cards
NSA-CEX02-J NSA-CEX04-J NSA-CEX08-J
NSA12/15-TX11 NSA12/15-TX12
Appendix
Appendix
NSA-CEX02-E NSA-CEX04-E NSA-CEX08-E
Appendix-28
Appendix 6
Using Virtual Memory
Appendix 6-1 Setting and Deleting the Paging File
Appendix 6 Using Virtual Memory
The NSA-series Industrial PC is set by default to not use virtual memory. When physical memory alone is not sufficient, it is necessary to set up a paging file and use virtual memory. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON NSA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.