If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON NSA12-15-TX11B. We hope that this OMRON NSA12-15-TX11B user guide will be useful to you.
Lastmanuals help download the user guide OMRON NSA12-15-TX11B.
Detailed instructions for use are in the User's Guide.
[. . . ] V238-E1-02
NSA-Series
NSA-Series Industrial PC
USER´S MANUAL
NSA-Series Industrial PC
NSA12/15-TX11B NSA12/15-TX11S NSA12/15-TX12B NSA12/15-TX12S
User's Manual
iv
Introduction
The NSA-series Industrial PC is an industrial, panel-mountable computer equipped with a Celeron M Processor and featuring a touch panel and display. Be sure to read and understand the functions and performance specifications in this manual prior to using it, and operate it as described herein.
Intended Audience
This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). · Personnel in charge of introducing FA systems into production facilities · Personnel in charge of designing FA systems · Personnel in charge of managing FA systems and facilities
Notice
This manual provides information for connecting and setting up an NSA-series Industrial PC. Be sure to read this manual before attempting to use it, and keep the manual close at hand for reference during operation.
OMRON, 2008
All rights reserved. [. . . ] Follow the correct procedure for turning the power ON and OFF.
3-18
3-6 Adjusting the Touch Panel and Display
3-6-1 Calibrating the Touch Panel
3-6 Adjusting the Touch Panel and Display
3-6-1 Calibrating the Touch Panel
This section describes the procedure for calibrating the touch panel. Calibrate the touch panel whenever it deviates markedly from its coordinate. Connect a USB keyboard and mouse to the NSA-series Industrial PC before calibrating the touch panel. Make sure the keyboard and mouse are properly connected. Start up the NSA-series Industrial PC and select Start Programs UPDD Settings from the bottom left corner of the screen to launch the settings program.
3
Installing the NSA-series Industrial PC and Connecting Peripheral Devices
Settings
3. Click the Calibration Tab on the Pointer Device Properties Menu, then click the Calibrate Button.
Calibrate Button
Make sure the EEPROM Calibration box is selected.
3-19
3-6
Adjusting the Touch Panel and Display
3-6-1 Calibrating the Touch Panel 4. Touch the tip of the arrow on the touch panel screen. When that calibration point is entered, an arrow will appear in another location. Touch the tip of the each arrow that appears.
Touch the tip of the arrow to input a calibration point.
3
Installing the NSA-series Industrial PC and Connecting Peripheral Devices
5. After all the calibration points have been entered, the Check calibration dialog box will appear. A message will be displayed prompting you to save the calibration data. If there were no problems with the calibration points, press the OK Button or the Enter Key on the keyboard. If there was a problem with a calibration point, do not touch anything for 10 seconds. The calibration data will be discarded and will not be saved.
OK Button
Note
· ·
The touch panel may deviate from its coordinates over time. We recommend that you re-calibrate the touch panel whenever that occurs. Input may fail if the touch panel is pressed continually at high speed. Confirm each input before moving on to the next entry.
Note
The calibration data is stored on the EEPROM in the NSA-series Industrial PC. If the EEPROM calibration box is not checked, the calibration data will be stored in Windows.
3-20
3-6 Adjusting the Touch Panel and Display
3-6-2 Adjusting the Display
3-6-2 Adjusting the Display
The brightness of the display can be set to high brightness, medium brightness, and low brightness using the adjustments for the LCD backlight brightness (a RAS Utility). By using the color correction function, you can further adjust the brightness of the entire display. This section will explain how to adjust the display using the color correction function. Start the NSA-series Industrial PC, and select Start - Program - IEGD IEGDGUI from the Start Menu.
3
Installing the NSA-series Industrial PC and Connecting Peripheral Devices
IEGDGUI
2. The IEGDGUI Dialog Box will be displayed. [. . . ] Memory Cards with the English version of Windows XP Embedded preinstalled. Memory Cards with the Japanese version of Windows XP Embedded preinstalled.
Appendix
Appendix
Appendix-28
Appendix 6 Using Virtual Memory
Appendix 6-1 Setting and Deleting the Paging File
Appendix 6 Using Virtual Memory
The NSA-series Industrial PC is set by default to not use virtual memory. When physical memory alone is not sufficient, it is necessary to set up a paging file and use virtual memory. This section will explain how to set up a paging file on the Memory Card so that virtual memory can be used.
There is a limit to the number of times that the Memory Card can be written. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON NSA12-15-TX11B
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.