Detailed instructions for use are in the User's Guide.
[. . . ] · Use either solid or stranded wires from 0. 2 to 1. 5 mm2 (AWG24 to AWG16). · Safe terminal arrangement: Coil terminals separated from contact terminals. · Unique ejector enables easy relay replacement. · Nameplate available · Finger-protection
Ordering Information
List of Models
1-pole for G2R1S Socket Clip & Release Lever Nameplate Socket Bridge P2RF-05-S P2RF-08-S P2CM-S R99-11 P2RM-SR, P2RM-SB 2-pole for G2R2S
Specifications
Ratings/Characteristics
Item Relay Dimensions (W×H×D) Rated voltage Rated carry current Applicable wires Number of wire connections Clamping force 10 A at 70°C P2RF05S G2R-1-S Series 18×92×38. 2 max. [. . . ] (3. 0 mm max. )
Flat-blade, Flared-tip
Cannot be used.
Examples: FACOM AEF. 2. 5×75E VESSEL No. 9900-(-)2. 5×75 WAGO 210-119 WIHA 260/2. 5×40 (AEF. 9900-(-)3×100) (260/3×50)
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.
Applicable Wires
Applicable Wire Sizes
0. 2 to 1. 5 mm2, AWG24 to AWG16
Wires with Ferules
Applicable Wire Type
Solid wires, standard wires, flexible wires, or wires with ferules can be used. (See note 1. ) < 2. 2 Diameter D (mm) 3. 2 (3. 5: see note 2. ) Conductor diameter d (mm) or length of sides a and b (mm) 1. 9
Note: 1. If the outer diameter D of the wire is less than 2. 2 mm and the exposed conductor length is less than 8mm potentially bad connection might occur in case wire is pushed to far inside. If the outer diameter D of the wire exceeds 3. 2 mm, it might be difficult to use double wiring.
Examples of Applicable Wires (Confirmed Using Catalog Information)
Type of wire Equipment wire 2491X BS6004 Switchgear BS6231 Switchgear BS6231 Tri-rated control and switchgear Conduit UL1007 UL1015 UL1061 UL1430 Conductor type Flexible Solid Solid Flexible Flexible Standard Flexible Flexible Flexible Flexible 18AWG 18AWG 16AWG 18AWG 0. 5 mm
2
See note 1, above.
Recommended wire sizes 0. 5, 0. 75, 1. 0 mm2 1. 0 mm2 0. 5, 0. 75 mm 1. 5 mm2 16AWG 18AWG, 16AWG
2 2
See note 2, above. 1. 5 mm2 1. 5 mm2 1. 0 mm2
0. 5, 0. 75, 1. 0, 1. 5 mm
4
Screwless Clamp Terminal Socket P2RFS
Wiring
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 8 to 9 mm.
Wire connection hole
Release hole Insert 8. 5 ±0. 5 mm Screwdriver
Fig. 1 Exposed Conductor Length Use the following wiring procedure.
1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted.
A
2. Insert the exposed conductor into the wire connection hole.
Wire connection holes
Release holes
Insert
A Fig. 2 Wire Connection Holes and Release Holes
3. Pull out the screwdriver.
Pull out
Screwless Clamp Terminal Socket
P2RFS
5
Precautions
Precautions for Connection
· Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e. g. , deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. · Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a sort-circuit.
General Precautions
· Use the clip to prevent relays floating or falling out of the socket. · Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. [. . . ] (There are two wiring holes for each terminal. )
Removing from Mounting Rail
To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below.
· Insert the screwdriver along the hole wall as shown below.
Screwdriver
· If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. · Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON P2RF S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.