User manual OMRON S82K

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON S82K. We hope that this OMRON S82K user guide will be useful to you.

Lastmanuals help download the user guide OMRON S82K.


Mode d'emploi OMRON S82K
Download
Manual abstract: user guide OMRON S82K

Detailed instructions for use are in the User's Guide.

[. . . ] Switch Mode Power Supply S82K (3/7. 5/15/30/50/90/100-W Models) Ultimate DIN-rail-mounting Power Supply with a Power Range of 3 to 100 W · EMI: EN 61204-3 class B · Input: 85 to 264 VAC (except 90-W and 100-W models) · Safety standards: UL 60950-1/508, cUL: C22. 2, cUR: No. 60950-1/14, Class 2 (UL, CSA), EN 60950-1 (=VDE 0805, Teil 1) · Undervoltage alarm indication available for standard models. Note: Refer to "Safety Precautions" on page 13. Model Number Structure Model Number Legend Note: Not all combinations are possible. Please refer to the list of models in "Ordering Information" on page 1. S82K 1 2 3 1. Power Factor Correction None: No P: Yes 2. [. . . ] To meet Class-2 requirements with the 100-W, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4. 2 A max. should be wired in series with the load to be connected to the Power Supply. Only then can the Power Supply output be considered as meeting Class 2. Switch Mode Power Supply S82K 3 Connections Block Diagrams S82K-003 (7. 5 W, Single Output) Fuse (1 A) AC (L) +V Noise filter AC (N) Inrush current Rectifier/ protection smoothing circuit circuit -V Rectifier/ smoothing circuit Drive control circuit Undervoltage alarm indicator Overload detection circuit Photocoupler Detector S82K-007 (7. 5 W, Dual Outputs) Fuse (1 A) AC (L) -V Noise filter AC (N) Inrush current Rectifier/ protection smoothing circuit circuit 3-terminal Rectifier/ smoothing REG circuit +V Drive control circuit Rectifier/smoothing circuit Overload detection circuit Photocoupler Detector Undervoltage alarm indicator S82K-015Undervoltage Alarm Output Terminals (DC LOW): S82K-@09024/-@10024 only. Parallel/Single Operation Selector: Set to "PARALLEL" for parallel operation. 6 Switch Mode Power Supply S82K Engineering Data Derating Curve (A: Standard mounting, B: Face-up mounting) 3-/7. 5-/15-/30-/50-/100-W Models Single-Unit Operation Load (%) Load (%) 100-W Models without PFC (S82K-10024) Parallel-Unit Operation Load (%) 100-W Models with PFC (S82K-P10024) Parallel-Unit Operation Installation A Installation A 90 Installation B 65 Installation A 65 S82K-P10024: 85-VAC input S82K-03005 Installation A Installation B S82K-P10024: 85-VAC input Installation B Ambient temperature (°C) Note: When using the 7. 5-W single-output models within the input voltage range between 90 and 110 VDC, the load rate will become 90% or less. Ambient temperature (°C) Ambient temperature (°C) 90-W Models Single-Unit Operation Load (%) S82K-P09024: 85-VAC input 65 Installation A Installation B Note: 1. 4. Ambient temperature (°C) Note that the derating curve may vary depending on the installation conditions. Multiple units cannot be installed in a configuration where they are lined up vertically. Use the 7. 5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. The cold-start time will be longer when using S82K-P09024 or S82K-P10024 with 85-VAC input. Mounting Top Top Note: Installations other than (A) and (B) are not possible. (A) Standard mounting (B) Face-up mounting Switch Mode Power Supply S82K 7 Overload Protection The Power Supply is provided with an overload protection function that protects the Power Supply from possible damage by overcurrent. When the output current rises above 105% min. of the rated current, the protection function is triggered, automatically decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. 3-/7. 5/15 W Models Output voltage (V) 30-/50 W Models Output voltage (V) 90-/100 W Models Output voltage (V) Intermittent operation 0 50 100 Output current (%) 0 50 100 Output current (%) 0 50 100 Output current (%) Note: 1. When connecting a load that has a built-in DC-DC converter, the overcurrent protection function may operate during start-up, thus preventing the Power Supply from starting. Internal parts may occasionally deteriorate or be damaged if a short-circuited or other overcurrent state continues during operation. When using the 7. 5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection function will operate at currents from 95% to 160% of the rated output current. When using the 90-W model at an ambient temperature of 25°C or less, the overload protection function will operate at currents from 101% to 111% of the rated output current. When using the 90-W model at an ambient temperature exceeding 25°C, the overload protection function will operate at currents from 92% to 111% of the rated output current. When using the 100-W model with PFC in parallel operation, operation is limited to a load ratio of 90% to 100% of the rated output current at 4. 2 A. When Using ± Output Models The +V output detects the total output power (+V output and -V output) to trigger the short-circuit protection against overcurrent. This protection varies depending on the -V output state. [. . . ] In this case, the rated current per S82KP10024 is 3. 78 A. Incorrect 3-, 7. 5-, 15-, 30-, 50-W Models +V INPUT -V Incorrect 3-, 7. 5-, 15-, 30-, 50- and 90-W Models +V INPUT -V +V INPUT -V INPUT -V +V Parallel Operation Precautions The length and thickness of each wire connected to the load must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Supply. Adjust the output voltage of each Power Supply so that there will be no difference in output voltage between each Power Supply. Wiring Do not apply more than 75-N force to the terminal block when tightening it. Ensure that input and output terminals are wired correctly. Minimum Output Current (S82K-00727/S82K-00728) The minimum output current of the S82K-00727 and S82K-00728 is restricted by the output voltage and control method. Note: All the outputs of the S82K-00727 and S82K-00728 are controlled by the +V output. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON S82K

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON S82K will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag