Detailed instructions for use are in the User's Guide.

[. . . ] (at 85 to 132 VAC input/at 170 to 264 VAC input, 100% load) 0. 8% max. (with rated input, 0 to 100% load) 0. 05%/°C max. (up to 90% of output voltage at rated output voltage/current) 20 ms min. 105% min. , voltage trailing intermittent operation (With the 600-W model, output is turned OFF at 5 s min. ) Yes No No No Natural air-cooling Yes (Red) Yes, 2 units max. [. . . ] (Includes the cover for 300-W and 600-W models. ) 2 S8PS S8PS Engineering Data Derating Curve Open-frame Type Load (%) Load (%) 50- to 150-W Model Forced air-cooling Covered Type 50- to 300-W Model Forced air-cooling, 600-W Model 50- to 150-W Model Natural air-cooling 50- to 300-W Model Natural air-cooling Note: Ambient temperature (°C) Ambient temperature (°C) 1. Forced air-cooling must be provided with an air volume of 1 m3/mm min. The derating curve shown is for standard installation. The derating curve depends on the mounting direction of the Power Supply. Standard Installation 50-W Model 20 mm min. 20 mm min. 20 mm min. 20 mm min. 20 mm min. 20 mm min. Standard Installation 100/150-W Model 30 mm min. 20 mm min. 30 mm min. 30 mm min. 20 mm min. 20 mm min. Standard Installation 300-W Model 30 mm min. 20 mm min. Standard Installation 600-W Model 20 mm min. 20 mm min. 3 S8PS Overload Protection 50- to 300-W Models The Power Supply is provided with an overload protection function that protects the load and the power supply from possible damage by overcurrent. The protection function operates when the load current rises above an overcurrent set value (105% of the rated load current). For a short-circuit or overcurrent lasting less than 20 seconds, output voltage is decreased to protect equipment. When the output current falls within the rated range, the overload protection function is automatically cleared. Output voltage (V) S8PS Overvoltage Protection The Power Supply is provided with an overvoltage protection function that protects the load and the Power Supply from possible damage by overvoltage. When the output voltage rises above a set value (115% of the rated output voltage), the protection function is triggered, shutting OFF the output voltage. If this occurs, reset the Power Supply by turning it OFF for 1 minute min. and then turning it ON again. Output voltage (V) Overvoltage protection operating Rated output voltage Intermittent operation Variable range Rating Output current (%) 0V Note: Do not continue using the S8PS under short-circuited or overcurrent conditions for longer than 20 seconds, otherwise the internal elements of the S8PS may be damaged or broken. 300- and 600-W Models Only The overvoltage protection-ON alarm indicator lights when the function is operating. Overheat Protection Function 600-W Model Only If the internal temperature of the S8PS rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to protect the internal elements of the S8PS and simultaneously a protection-ON alarm indicator will be lit. To reset the S8PS turn OFF the input voltage, leave the S8PS for at least one minute and then apply the input voltage again. 600-W Models If an excessive current flows for 5 s or more, the output will be turned OFF and simultaneously protection-ON alarm indicator will be lit. To reset the S8PS, turn OFF the input voltage, leave the S8PS for at least three minutes, and then apply the input voltage again. Note: Do not continue using the S8PS with the output terminals short-circuited or the overcurrent condition continued, otherwise the internal elements of the S8PS may be damaged or broken. Inrush Current, Rise Time, Hold Time Input ON AC input voltage Input OFF Inrush current on input application AC input current 90% 96. 5% Output voltage Rise time (1, 000 ms max. ) Hold time (20 ms min. ) 4 S8PS S8PS Operation Block Diagrams S8PS-050jjjj (50 W) Rectifier AC(L) INPUT AC(N) Fuse (4 A) Noise filter Inrush current protection circuit Harmonic current control Smoothing Rectifier/ smoothing circuit +V DC OUT ­V Drive control circuit Overload detection circuit Detector Overload detection circuit S8PS-10024jj (100 W) S8PS-15024jj (150 W) S8PS-30024jj (300 W) Rectifier AC(L) Fuse* INPUT AC(N) Inrush current protection circuit *Fuse capacity 100-W: 6. 3 A 150-W: 6. 3 A 300-W: 8 A Noise filter Harmonic current control Smoothing ­V Rectifier/ smoothing circuit +V DC OUT Control circuit Overload detection circuit Detector Overload detection circuit S8PS-60024C (600 W) AC(L) INPUT AC(N) Fuse (15 A) Noise filter Rectifier +V DC OUT Inrush current protection circuit Harmonic current control Smoothing Rectifier/ smoothing circuit ­V Control circuit Fan Detector Overcurrent detection Overheat detection Overload detection circuit 5 S8PS S8PS Dimensions Note: All units are in millimeters unless otherwise indicated. Front-mounting Bracket Type The Front-mounting Bracket is provided as an accessory. Screws for fixing the Bracket to the panel are not provided. S8PS-050jj (50 W) S8PS-050jjjC (50 W) 11. 5 max. Five, M4 terminal screws 3. 5 dia. 3. 5 dia. Three, M3 (depth: 6 max. ) Front-mounting Bracket for 50-W Models Mounting Holes 1. 5 9 Two, 3. 5 dia. 11 4. 6 15±0. 2 Using the Mounting Bracket Attach the Mounting Bracket to the panel and loosely tighten the two screws. [. . . ] Forced air-cooling is highly recommended. It is recommended that the clearance around the Power Supply be larger than those shown on page 3 under Standard Installation. +V INPUT ­V 11 S8PS Parallel Operation Only 300- and 600-W models can be in parallel operation provided that they are operated under 90% of the ratings. Do not operate any other models in parallel. Make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will have no voltage drop differences. Load +V INPUT ­V S8PS Fan Set: Fan (above), four M4 x 35 sems screws, instruction sheet, and packing case Replace the fan as shown in the following illustration. +V INPUT ­V Fan Replacement The service life of the fan is approximately 50, 000 hours (at 25°C). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON S8PS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON S8PS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag