User manual OMRON SYSDRIVE 3G3JV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON SYSDRIVE 3G3JV. We hope that this OMRON SYSDRIVE 3G3JV user guide will be useful to you.

Lastmanuals help download the user guide OMRON SYSDRIVE 3G3JV.


Mode d'emploi OMRON SYSDRIVE 3G3JV
Download
Manual abstract: user guide OMRON SYSDRIVE 3G3JV

Detailed instructions for use are in the User's Guide.

[. . . ] I546-E1-02 0675398-6B SETUP MANUAL SYSDRIVE 3G3JV Compact Simplified Inverters Thank you for choosing this SYSDRIVE 3G3JV-series product. Proper use and handling of the product will ensure proper product performance, will lengthen product life, and may prevent possible accidents. Please read this manual thoroughly and handle and operate the product with care. 1. To ensure safe and proper use of the OMRON Inverters, please read this SETUP MANUAL and the USER'S MANUAL (Cat. [. . . ] cy (FMAX) n10 (010A) n11 (010B) Output Maxivoltage mum n10 voltage (VMAX) (VMAX) n13 Maxi(VC) mum Fren15 voltage quency (VMIN) (Hz) frequen0 n14 n12 n11 n09 (FMIN) (FB) (FA) (FMAX) ( )() () ( ) cy (FA) Middle Note Set the parameters so that output the following condition will be frequensatisfied. cy (FB) n14 x n12 < n11 x n09 14 12 11 09 Middle output frequen- Note The value set in n13 will be ignored if parameters n14 and cy voltage n12 are the same in value. (VC) Minimum output frequency (FMIN) Minimum output frequency voltage (VMIN) Chapter 3 Default setting Changes during operation No Memo 60. 0 1 to 255 200 No 0. 2 to 400 60. 0 No n12 (010C) n13 (010D) 0. 1 to 399 1. 5 No 1 to 255 12 No n14 (010E) 0. 1 to 10. 0 1. 5 No n15 (010F) 1 to 50 (see note 2) 12. 0 No n16 (0110) n17 (0111) n18 (0112) n19 (0113) Acceleration time 3 Deceleration time 3 Acceleration time 4 Deceleration time 4 Acceleration time: The time required to go from 0% to 100% of the maximum frequency. Deceleration time: The time required to go from 100% to 0% of the maximum frequency. Note The actual acceleration or deceleration time is obtained from the following formula. Acceleration/Deceleration time = (Acceleration/Deceleration time set value) × (Frequency reference value) ÷ (Max. frequency) 0. 0 to 999 10. 0 Yes 10. 0 Yes 10. 0 Yes 10. 0 Yes 3-4 List of Parameters Parameter Name No. (Hex)) n20 S-shape accel(0114) eration/ deceleration characteristic Description Setting range Default setting Chapter 3 Changes during operation No Memo Used to set S-shape acceleration/de- 0 to 3 celeration characteristics. 0: No S-shape acceleration/deceleration (trapezoidal acceleration/deceleration) 1: S-shape acceleration/deceleration characteristic time 0. 2 s 2: S-shape acceleration/deceleration characteristic time 0. 5 s 3: S-shape acceleration/deceleration characteristic time 1. 0 s Note When the S-shape acceleration/deceleration characteristic time is set, the acceleration and deceleration times will be lengthened according to the S-shape at the beginning and end of acceleration/deceleration. 0 3-5 List of Parameters Parameter Name No. (Hex)) n21 Frequency (0115) reference 1 n22 Frequency (0116) reference 2 n23 Frequency (0117) reference 3 n24 Frequency (0118) reference 4 n25 Frequency (0119) reference 5 n26 Frequency (011A) reference 6 n27 Frequency (011B) reference 7 n28 Frequency (011C) reference 8 n29 Inching frequen(011D) cy command Description Setting range Default setting Chapter 3 Changes during operation Yes Memo Used to set internal frequency references. Note Frequency reference 1 is enabled in remote mode with n03 for frequency reference selection set to 1. Note These frequency references are selected with multi-step speed references (multi-function input). 0. 0 to max. 6. 0 frequency 0. 0 Yes 0. 0 Yes 0. 0 Yes 0. 0 Yes 0. 0 Yes 0. 0 Yes 0. 0 Yes Used to set the inching frequency command. Note The inching frequency command is selected with the inching command (multi-function input). The inching frequency command takes precedence over the multi-step speed reference. 6. 0 Yes 3-6 List of Parameters Parameter Name No. (Hex)) n30 Frequency (011E) reference upper limit n31 Frequency (011F) reference lower limit n32 Rated motor (0120) current Description Setting range Default setting Chapter 3 Changes during operation No Memo Used to set the upper and lower fre- 0 to 110 quency reference limits in percentage based on the maximum frequency as 100%. Note If n31 is set to a value less than the minimum output frequency (n14), the Inverter will 0 to 110 have no output when a frequency reference less than the minimum output frequency input is input. Used to set the rated motor current for motor overload detection (OL1) based on the rated motor current. Note Motor overload detection (OL1) is disabled by setting the parameter to 0. 0. Note The rated motor current is default to the standard rated current of the maximum applicable motor. Used to set the motor overload detection (OL1) for the electronic thermal characteristics of the motor. 0: Protection characteristics for general-purpose induction motors 1: Protection characteristics for inverter-dedicated motors 2: No protection Note If a single Inverter is connected to more than one motor, set the parameter to 2 for no protection. [. . . ] As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. 14. 15. 16. 17. 18. Certain Precautions on Specifications and Use 1. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON SYSDRIVE 3G3JV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON SYSDRIVE 3G3JV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag