Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON TL-W. We hope that this OMRON TL-W user guide will be useful to you.
Lastmanuals help download the user guide OMRON TL-W.
Detailed instructions for use are in the User's Guide.
[. . . ] Models with different response frequency are available. These model numbers take the form TL-W5MD#5 (e. g. , TL-W5MD15)
TL-W
D-53
Rating/Performance
DC 2-wire Models
Item Sensing distance Setting distance Differential distance Sensing object Standard sensing object Response frequency Rated supply voltage (operating voltage) Leakage current Control output Switching capacity Residual voltage Model 5 mm ±10% 0 to 4 mm 10% max. Ferrous metal(Sensitivity decreases with non-ferrous metals) Iron, 18 x 18 x 1 mm 0. 5 kHz 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. [. . . ] 12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max. 8 mA at 12 VDC, 15 mA at 24 VDC 12 VDC 100mA max. , 24 VDC 200 mA max. (under load current of 200 mA with cable length of 2 m)
Current consumption 15 mA max. at 24 VDC (no-load)
Switching capacity Control output Residual voltage Indicator lamp Operating status (with sensing object approaching) Protective circuits Ambient temperature Ambient humidity Temperature influence
NPN open collector 100 mA max. (under load current of 100 mA with cable length of 2 m) Detection indicator (red LED)
NPN open collector 12 VDC 50 mA max. (under load current of load current of 50 mA with cable 200 mA with cable length of 2 m) length of 2 m)
Reverse connection protection, surge absorber Operating/Storage: -25°C to 70°^C (with no icing or condensation) Operating/Storage: 35% to 95%RH (with no condensation) ±10% max. of sensing distance at 23°C within the temperature range of -25°C and 70°C
±2. 5% max. of sensing distance within a range of ±10% tance within a Voltage influence within a range of ±10% of rated range of ±20% of rated power supply voltage power supply voltage of rated power supply voltage Insulation resistance 50 M min. (at 500 VDC) between energized parts and case Dielectric strength 1000 VAC 50/60 Hz for 1 min between energized part and case Vibration resistance 10 to 55 Hz, 1. 5 mm double amplitude for 2 hours each in X, Y, and Z directions Destruction: 500 m/s2 for 10 times each in X, Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions Y, and Z directions Protective structure IEC60529 IP67 Connection method Pre-wired models (standard length: 2 m) Weight 30 g Approx. 180 g (Packed state) Heat-resistant Case Heat-resistant ABS resin Diecast aluminum ABS resin Material Sensing Heat-resistant ABS resin surface Mounting bracket, Accessories Instruction manual instruction manual
TL-W
D-55
TL-W
NO
C1 models: NO C2 type: NC
E1 models, F1 models: NO E2 models, F2 models: NC
Characteristic data (typical)
Sensing Distance vs. Sensing Object TL-W1R5M#
Sensing distance X (mm) 4
TL-W3M#
Sensing distance X (mm) 4
TL-W5MB#/C#
Sensing distance X (mm)
7
#d
X
t=1mm
#d
6
X
t=1mm
Iron
3
3
Iron
Stainless steel (SUS304)
5
4
Stainless steel (SUS304)
2 Iron
Stainless steel (SUS304)
2 Brass Aluminum Copper Brass Copper Aluminum 1
3 Brass Aluminum Copper 1
1
2
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
Side length of sensing object d (mm)
Side length of sensing object d (mm)
Side length of sensing object d (mm)
TL-W5E#/-W5F#/-W5MD#
Sensing distance X (mm) 6
TL-W20#
Sensing distance X (mm) 24 22 20 18 16 14 12 Brass 10 8 Aluminum 6 4 2 Aluminum Brass
Stainless steel (SUS304)
#d
X
t=1mm
#d
X
Iron
t=1mm
5
Iron
4
Stainless steel (SUS304)
3
2
1
0
5
10
15
20
25
30
35
40 45
0
10
20
30
40
50
60
70
80
90
Side length of sensing object d (mm)
Side length of sensing object d (mm)
D-56
Inductive Sensors
Output Circuit Diagram
DC 2-wire Models
Operating status Model Timing chart
Setting position Stable sensing Unstable zone Sensing zone
Output circuit
Non-sensing zone Sensing object (%)
Proximity Sensor
NO
TL-W5MD1
100 80(TYP) Rated sensing distance
0 ON OFF ON OFF ON OFF Control output
Blue 0V
Setting indicator (green)
Brown
Load
+V
Operation indicator (red)
Main circuit
Non-sensing zone Sensing object (%)
Sensing zone
Proximity Sensor
Note: The Load can be connected to either the +V and 0-V side.
100 Rated sensing distance 0 ON OFF ON OFF Control output Operation indicator (red)
NC
TL-W5MD2
DC 3-wire Models
Operating status Model Timing chart
Yes No
Output circuit
Sensing object
NO
TL-W1R5M#1 TL-W3M#1 TL-W5M#1
Output transistor ON (load) OFF ON Operation indicator OFF (red)
Brown 100W Load Main circuit Output Blue
+V
Sensing object
Yes No
NC
TL-W3M#2 TL-W5MC2
0V
Output transistor ON (load) OFF ON Operation indicator (red) OFF
* Maximum load current: 100 mA
Sensing object
Yes No
Brown +V
NO
TL-W1R5B1 TL-W3MB1 TL-W5MB1
Output transistor ON (load) OFF ON Operation indicator OFF (red)
Main circuit
Black
Yes Sensing object No
Load 100W Blue 0V
NC
TL-W3MB2 TL-W5MB2
Output transistor ON (load) OFF ON Operation indicator (red) OFF
Sensing object
Yes No
Brown 100W 4. 7kW Main circuit 2. 2W *1 Black Output *2 Blue
Load
NO
TL-W5E1 TL-W20ME1
Load Operate (between brown and black) Release Output voltage (between blue and black) H L
+V
ON Operation indicator (red) OFF
Tr 0V
Sensing object
Yes No
NC
TL-W5E2 TL-W20ME2
Load Operate (between brown and black) Release Output voltage (between blue and black) H L
* Maximum load current: 100 mA * 2. Current flows in this direction if the circuit incorporates the transistor.
ON Operation indicator (red) OFF
TL-W
D-57
TL-W
Black *
Operating status
Model
Timing chart
Sensing object Yes No
Output circuit
NO
TL-W5F1
Load Operate (between brown and black) Release Output voltage (between blue and black) Operation indicator (red)
Sensing object
Brown +V Tr Main circuit 4. 7kW 100W Blue *2 Black 2. 2W Output *1
Load
H L ON OFF
Yes No
Load Operate (between brown and black) Release
0V
NC
TL-W5F2
Output voltage (between blue and black)
H L
* 1. Current flows in this direction if the circuit incorporates the transistor.
ON Operation indicator (red) OFF
Precautions
Correct Use
Design Effects of Surrounding Metal Provide a minimum distance between the Sensor and the surrounding metal as shown in the table below. Front Surface Sensing Type (Not exceeding the sensor head height). Mutual Interference If two or more Sensors are mounted face to face or side by side, keep them separate at the following minimum distance.
A B
m
Sensing surface l Proximity Sensor
Sensing surface
B
l
Proximity Sensor
Mutual Interference (unit: mm)
Model TL-W1R5M# Length A 75 (50) 90 (60) 120(80) 200(100) 50 B 120(60) 200(100) 60(30) 200(100) 35
Effects of Surrounding Metal(Unit: mm)
Model TL-W1R5M# TL-W3M# TL-W5MD# TL-W5M# TL-W20ME# TL-W5E#/-W5F# Length l 2 3 5 25 0 16 0 0 m n 8 12 20 100 20
TL-W3MC# TL-W5MD# TL-W5MC# TL-W20ME# TL-W5E#/-W5F#
Note: The above values in parentheses are applicable when using two sensors with different frequencies.
Installation · Use M3 flat-head screws to install TL-W1R5M# and · TL-W3M#. · Ensure that the resin cover should be tightened with · a torque according to the following table.
Model TL-W1R5MC1 TL-W3MC# TL-W5MD# TL-W20M# 1. 5 Nm 0. 98 Nm Tensile strength (torque)
Adjustment Power ON Please note that the power injection AND connection generate an error pulse for approximately 1 ms.
D-58
Inductive Sensors
Dimensions (Unit: mm)
TL-W1R5M#1
25 16±0. 2 5±0. 2 8 8 Sensing surface 9 * Mounting hole for M3 pan-head screw
TL-W3M##
27 17±0. 2 3 Operation indicator (red) 10 8 9 (See note) Mounting hole for M3 pan-head screw 90° 6 dia. [. . . ] TL-W5MC1: Vinyl-insulated round cable with three conductors, 4 dia. (conductor cross-sectional area: 0. 2 mm2; insulation diameter: 1. 2 mm); standard length: 2 m TL-W5MD# : Vinyl-insulated round cable with two conductors, 4 dia. (conductor cross-sectional area: 0. 3 mm²; insulation diameter: 1. 3 mm); standard length: 2 m * 2. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON TL-W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.