User manual OMRON TL-W DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON TL-W. We hope that this OMRON TL-W user guide will be useful to you.

Lastmanuals help download the user guide OMRON TL-W.


Mode d'emploi OMRON TL-W
Download
Manual abstract: user guide OMRON TL-WDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Models with different response frequency are available. These model numbers take the form TL-W5MD#5 (e. g. , TL-W5MD15) TL-W D-53 Rating/Performance DC 2-wire Models Item Sensing distance Setting distance Differential distance Sensing object Standard sensing object Response frequency Rated supply voltage (operating voltage) Leakage current Control output Switching capacity Residual voltage Model 5 mm ±10% 0 to 4 mm 10% max. Ferrous metal(Sensitivity decreases with non-ferrous metals) Iron, 18 x 18 x 1 mm 0. 5 kHz 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. [. . . ] 12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max. 8 mA at 12 VDC, 15 mA at 24 VDC 12 VDC 100mA max. , 24 VDC 200 mA max. (under load current of 200 mA with cable length of 2 m) Current consumption 15 mA max. at 24 VDC (no-load) Switching capacity Control output Residual voltage Indicator lamp Operating status (with sensing object approaching) Protective circuits Ambient temperature Ambient humidity Temperature influence NPN open collector 100 mA max. (under load current of 100 mA with cable length of 2 m) Detection indicator (red LED) NPN open collector 12 VDC 50 mA max. (under load current of load current of 50 mA with cable 200 mA with cable length of 2 m) length of 2 m) Reverse connection protection, surge absorber Operating/Storage: -25°C to 70°^C (with no icing or condensation) Operating/Storage: 35% to 95%RH (with no condensation) ±10% max. of sensing distance at 23°C within the temperature range of -25°C and 70°C ±2. 5% max. of sensing distance within a range of ±10% tance within a Voltage influence within a range of ±10% of rated range of ±20% of rated power supply voltage power supply voltage of rated power supply voltage Insulation resistance 50 M min. (at 500 VDC) between energized parts and case Dielectric strength 1000 VAC 50/60 Hz for 1 min between energized part and case Vibration resistance 10 to 55 Hz, 1. 5 mm double amplitude for 2 hours each in X, Y, and Z directions Destruction: 500 m/s2 for 10 times each in X, Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions Y, and Z directions Protective structure IEC60529 IP67 Connection method Pre-wired models (standard length: 2 m) Weight 30 g Approx. 180 g (Packed state) Heat-resistant Case Heat-resistant ABS resin Diecast aluminum ABS resin Material Sensing Heat-resistant ABS resin surface Mounting bracket, Accessories Instruction manual instruction manual TL-W D-55 TL-W NO C1 models: NO C2 type: NC E1 models, F1 models: NO E2 models, F2 models: NC Characteristic data (typical) Sensing Distance vs. Sensing Object TL-W1R5M# Sensing distance X (mm) 4 TL-W3M# Sensing distance X (mm) 4 TL-W5MB#/C# Sensing distance X (mm) 7 #d X t=1mm #d 6 X t=1mm Iron 3 3 Iron Stainless steel (SUS304) 5 4 Stainless steel (SUS304) 2 Iron Stainless steel (SUS304) 2 Brass Aluminum Copper Brass Copper Aluminum 1 3 Brass Aluminum Copper 1 1 2 0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) TL-W5E#/-W5F#/-W5MD# Sensing distance X (mm) 6 TL-W20# Sensing distance X (mm) 24 22 20 18 16 14 12 Brass 10 8 Aluminum 6 4 2 Aluminum Brass Stainless steel (SUS304) #d X t=1mm #d X Iron t=1mm 5 Iron 4 Stainless steel (SUS304) 3 2 1 0 5 10 15 20 25 30 35 40 45 0 10 20 30 40 50 60 70 80 90 Side length of sensing object d (mm) Side length of sensing object d (mm) D-56 Inductive Sensors Output Circuit Diagram DC 2-wire Models Operating status Model Timing chart Setting position Stable sensing Unstable zone Sensing zone Output circuit Non-sensing zone Sensing object (%) Proximity Sensor NO TL-W5MD1 100 80(TYP) Rated sensing distance 0 ON OFF ON OFF ON OFF Control output Blue 0V Setting indicator (green) Brown Load +V Operation indicator (red) Main circuit Non-sensing zone Sensing object (%) Sensing zone Proximity Sensor Note: The Load can be connected to either the +V and 0-V side. 100 Rated sensing distance 0 ON OFF ON OFF Control output Operation indicator (red) NC TL-W5MD2 DC 3-wire Models Operating status Model Timing chart Yes No Output circuit Sensing object NO TL-W1R5M#1 TL-W3M#1 TL-W5M#1 Output transistor ON (load) OFF ON Operation indicator OFF (red) Brown 100W Load Main circuit Output Blue +V Sensing object Yes No NC TL-W3M#2 TL-W5MC2 0V Output transistor ON (load) OFF ON Operation indicator (red) OFF * Maximum load current: 100 mA Sensing object Yes No Brown +V NO TL-W1R5B1 TL-W3MB1 TL-W5MB1 Output transistor ON (load) OFF ON Operation indicator OFF (red) Main circuit Black Yes Sensing object No Load 100W Blue 0V NC TL-W3MB2 TL-W5MB2 Output transistor ON (load) OFF ON Operation indicator (red) OFF Sensing object Yes No Brown 100W 4. 7kW Main circuit 2. 2W *1 Black Output *2 Blue Load NO TL-W5E1 TL-W20ME1 Load Operate (between brown and black) Release Output voltage (between blue and black) H L +V ON Operation indicator (red) OFF Tr 0V Sensing object Yes No NC TL-W5E2 TL-W20ME2 Load Operate (between brown and black) Release Output voltage (between blue and black) H L * Maximum load current: 100 mA * 2. Current flows in this direction if the circuit incorporates the transistor. ON Operation indicator (red) OFF TL-W D-57 TL-W Black * Operating status Model Timing chart Sensing object Yes No Output circuit NO TL-W5F1 Load Operate (between brown and black) Release Output voltage (between blue and black) Operation indicator (red) Sensing object Brown +V Tr Main circuit 4. 7kW 100W Blue *2 Black 2. 2W Output *1 Load H L ON OFF Yes No Load Operate (between brown and black) Release 0V NC TL-W5F2 Output voltage (between blue and black) H L * 1. Current flows in this direction if the circuit incorporates the transistor. ON Operation indicator (red) OFF Precautions Correct Use Design Effects of Surrounding Metal Provide a minimum distance between the Sensor and the surrounding metal as shown in the table below. Front Surface Sensing Type (Not exceeding the sensor head height). Mutual Interference If two or more Sensors are mounted face to face or side by side, keep them separate at the following minimum distance. A B m Sensing surface l Proximity Sensor Sensing surface B l Proximity Sensor Mutual Interference (unit: mm) Model TL-W1R5M# Length A 75 (50) 90 (60) 120(80) 200(100) 50 B 120(60) 200(100) 60(30) 200(100) 35 Effects of Surrounding Metal(Unit: mm) Model TL-W1R5M# TL-W3M# TL-W5MD# TL-W5M# TL-W20ME# TL-W5E#/-W5F# Length l 2 3 5 25 0 16 0 0 m n 8 12 20 100 20 TL-W3MC# TL-W5MD# TL-W5MC# TL-W20ME# TL-W5E#/-W5F# Note: The above values in parentheses are applicable when using two sensors with different frequencies. Installation · Use M3 flat-head screws to install TL-W1R5M# and · TL-W3M#. · Ensure that the resin cover should be tightened with · a torque according to the following table. Model TL-W1R5MC1 TL-W3MC# TL-W5MD# TL-W20M# 1. 5 Nm 0. 98 Nm Tensile strength (torque) Adjustment Power ON Please note that the power injection AND connection generate an error pulse for approximately 1 ms. D-58 Inductive Sensors Dimensions (Unit: mm) TL-W1R5M#1 25 16±0. 2 5±0. 2 8 8 Sensing surface 9 * Mounting hole for M3 pan-head screw TL-W3M## 27 17±0. 2 3 Operation indicator (red) 10 8 9 (See note) Mounting hole for M3 pan-head screw 90° 6 dia. [. . . ] TL-W5MC1: Vinyl-insulated round cable with three conductors, 4 dia. (conductor cross-sectional area: 0. 2 mm2; insulation diameter: 1. 2 mm); standard length: 2 m TL-W5MD# : Vinyl-insulated round cable with two conductors, 4 dia. (conductor cross-sectional area: 0. 3 mm²; insulation diameter: 1. 3 mm); standard length: 2 m * 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON TL-W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON TL-W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag