User manual OMRON V400-H101

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON V400-H101. We hope that this OMRON V400-H101 user guide will be useful to you.

Lastmanuals help download the user guide OMRON V400-H101.


Mode d'emploi OMRON V400-H101
Download
Manual abstract: user guide OMRON V400-H101

Detailed instructions for use are in the User's Guide.

[. . . ] Handheld 2D Code Reader V400-H101/201 User's Manual Cat. No. Z222-E1-01 Introduction Thank you for purchasing the OMRON V400-H101/H201. This manual describes the functions, performance, and application methods of the V400-H101/H201. This manual is intended for personnel with knowledge of electrical systems. [. . . ] Up to 38 characters can be displayed. Image Display This area displays images taken by the Camera. LED Indicators Indicator Power Memory Card Location On the bottom of the monitor Beside the Memory Card slot Details Lit when power is turned ON, and remains lit during operation Lit when the Memory Card is being accessed. Do not remove the Memory Card while this indicator is lit. V400-H101/201 User's Manual 35 Section 3 Reading 2D Code RS-232C Communications Output Output for Successful Readings Read data is output in the following format. Header Read data Footer Output for Unsuccessful Readings Nothing is output with the default setting. An error code output, however, can be set for unsuccessful readings. (See note. ) Note: NG output setting When the NG output is set to ON, the output contents can be changed. Output contents when NG output is ON: Section 3 Outputting Results · The NG mark is displayed on the monitor in red. · The data ?E000 is sent via RS-232C communications. Header ?E000 Footer 36 V400-H101/201 User's Manual Section 3 Reading 2D Code Functions Sleep The Handheld 2D Code Reader is equipped with a sleep function for reducing power consumption. The Code Reader is automatically set to sleep when operation is not performed for a specified period of time. · 30 Seconds Lapsed (Default Setting) Press either of the trigger buttons to return to resume normal operating status from sleep status. Section 3 Functions Data Conversion on Display Normally, 2D code data that is read is displayed as is on the monitor. This function compares the read data, converts into separate text strings and displays the converted data. p. 49 OK DS1300 SD OK Produced January DS1300 SD Example display when function is OFF Example display when function is ON Data Accumulation The read data is not only output via RS-232C communications, but is created as a file in the Memory Card and saved in CSV format. p. 48 V400-H101/201 User's Manual 37 Section 3 Reading 2D Code MEMO Section 3 Functions 38 V400-H101/201 User's Manual Section 4 System Settings This section describes the methods used to install and set the 2DCR Configear software. Overview Installing the 2DCR Configear Communications Using the 2DCR Configear Creating Setting Files Using the 2DCR Configear Uploading from the Memory Card 40 41 43 46 52 Section 4 System Settings V400-H101/201 User's Manual 39 Section 4 System Settings Overview Installing the Setting Software computer. p. 41 Obtain the 2DCR Configear application software from the Internet and install it on a personal Creating the Setting File Create the setting file using the 2DCR Configear. Specify the required settings using the 2DCR Configear, and create as a file. p. 46 Section 4 Overview The following items can be set. Function settings Uploading Data Upload the created setting data to the Handheld 2D Code Reader. The following two loading methods are available. p. 52 · Using the Memory Card · Using the 2DCR Configear 40 V400-H101/201 User's Manual Section 4 System Settings Installing the 2DCR Configear Obtain the 2DCR Configear and install it on a personal computer. Contact the OMRON representative nearest you regarding the 2DCR Configear. 1. Open the setup. exe file downloaded from the Sensing Web website. The following window will be displayed. 2. Click the OK Button. Section 4 Installing the 2DCR Configear 3. Click the Button. V400-H101/201 User's Manual 41 Section 4 System Settings 4. Click the Continue Button. Setup will start when the Continue Button is clicked. Section 4 Installing the 2DCR Configear 5. Click the OK Button. 42 V400-H101/201 User's Manual Section 4 System Settings Communications Using the 2DCR Configear The 2DCR Configear can be used to communicate with the Handheld 2D Code Reader. Menu Communication Setting Connect Button Connects or disconnects from the port. Section 4 Communications Using the 2DCR Configear Status display Direct Command Input Sends the input text string to the Handheld 2D Code Reader. Communication Log Display Form Selects the communication log display format as either text format or hexadecimal. Communication Setting The following items can be set. Setting item Port No. Baud Rate Parity Data Length Stop Bit Header/Footer Prefix Settings Suffix FCS COM1* to COM 9 9, 600*, 19, 200, or 38, 400 None*, odd, or even 7 bits or 8 bits* 1sbit* or 2 bits Send None*, 02 <STX>, or 1B <ESC> Receive None*, 02 <STX>, or 1B <ESC> Send 03 <ETX>, 0A <LF>, 0D <CR>*, or 0D0A <CR+LF> Receive 03 <ETX>, 0A <LF>, 0D <CR>* or 0D0A <CR+LF> Send ON or OFF* Receive ON or OFF* Sets the header, footer, and FCS for receiving to the same settings as for sending. Same as Send The default settings are indicated with an asterisk. Operation is not possible when the port is connected. V400-H101/201 User's Manual 43 Section 4 System Settings Menu File Save Log. . . Saves the data displayed in the communication log as a text file. Save Environment Saves the settings made in the communications settings. End Ends the 2DCR Configear. Edit Copy Log Copies the log displayed in the communication log to the clipboard. [. . . ] with 4 conductors Standard length: 2 m Connector V400-W20-2M Interface connector Ambient temperature Ambient humidity Ambient environment Materials D-sub, 9-pin, male V400-W21-2M D-sub, 9-pin, female Operating: 0 to 40°C Storage: -25 to 60°C 35% to 85% (with no condensation) No corrosive gases Cable sheath: Heat-resistant vinyl chloride Special connector: PPS, PBT, POM D-sub connector: ABS 30 mm Approx. 100 g Appendices Specifications and Dimensions Minimum bending radius Weight V400-H101/201 User's Manual 61 Appendices Contactor V400-AC1 (Unit: mm) 90. 5 Material Weight POM (antistatic grade) Approx. 20 g 62 V400-H101/201 User's Manual 48. 5 40 V400-AC1 53 Appendices Specifications and Dimensions Appendices Stand V400-AS1 Two 4. 2 dia. (Unit: mm) 20 46. 1 68 Appendices Specifications and Dimensions 133. 1 58. 4 V400-AS1 Material Weight ABS Approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V400-H101

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON V400-H101 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag