[. . . ] No. Z219-E1-02
V600 Series
RFID System
USER´S MANUAL
Introduction ÇÕǹÇ?Ç
Introduction
Application Considerations (Read and understand this information first. )
Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 ëÊ 1 èÕ ëÊ 2 èÕ ëÊ 3 èÕ ëÊ 4 èÕ
Section 1 Product Overview
Section 2 Communications Preparations
Section 3 Commands
Section 4 Functions
Section 5 Troubleshooting
Section 6 Appendices
RFID System
V600-CHUD V600-CH1D-V2 V600 Series Hand-held Reader Writer Hand-held Reader Writer Data Carriers
User's Manual
Introduction
Introduction
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] The end code 00 indicates normal completion. For details on end codes, refer to End code List.
p. 95
Section 3l Communications Commands
RFID System
User's Manual
63
Section 3 Commands
COPY READ (RC)
This command reads data to be copied using the COPY WRITE (WC) command. A response is not sent for read data.
Command
Processing area Command Data number code setting setting
Read area start address × × × × ×
Number of read bytes × × ×
Terminator CR 2
R 2
C
H 1
1 1
0 or 4
0 or 4
Communications Commands Section 3
Data setting Processing area number setting Read area start address
Always H. Specifies the start address of the area in the Data Carrier to be read from in 4-digit hexadecimal code (can be omitted). Setting range: 0000h to 1FFFh (when omitted, all areas in the Data Carrier are read) Note: If omitting the start address, also omit the number of read bytes. All areas of an 8-Kbytes Data Carrier cannot be copied.
Number of read bytes
Specifies the number of bytes to be read from the Data Carrier in 4-digit hexadecimal. Setting range: 0001h to 0800h
Response
Command End code Terminator code R 2 C 0 2 0 2 CR
End code
Indicates the execution result for the command. The end code 00 indicates normal completion. For details on end codes, refer to End code List.
p. 95
The COPY READ command can be executed more than once for data that has already been copied. If the copy operation fails, however, the copied data that was held will be deleted.
64
RFID System
User's Manual
Section 3 Commands
COPY WRITE (WC)
This command writes data to the Data Carrier that was read using the COPY READ (RC) command. The Hand-held Reader Writer responds when communications between the Hand-held Reader Writer and Data Carrier have ended.
Command
Processing area Command Data number code setting setting Terminator
W 2
C
H 1
1 1 2
CR
Section 3l Communications Commands
Data setting Processing area number setting
Always H. Always 1.
Response
Command code End code Terminator W 2 C 0 2 0 2 CR
End code
Indicates the execution result for the command. The end code 00 indicates normal completion. For details on end codes, refer to End code List.
p. 95
RFID System
User's Manual
65
Section 3 Commands
EXPANSION DIVIDED READ (XR)
This command divides and reads up to 2 Kbytes of data. If the Data Carrier is not in communications range, an error response (end code: 72 = Data Carrier non-existent) will be returned. The host device cannot send commands to the Hand-held Reader Writer until all the responses have been received.
Command
Processing area
Command Data number setting setting code X 2 R A/H 1 1 1
Read area start address × × 4 × × ×
Number of read bytes × 4 × ×
Terminator CR 2
Communications Commands Section 3
Data setting
Sets the code format used to send responses for read data. Specifies the start address of the area in the Data Carrier to be read from in 4-digit hexadecimal code. Setting range: 0000h to 1FFFh Specifies the number of bytes to be read from the Data Carrier in 4-digit hexadecimal. The maximum number of bytes that can be read at one time is 2, 048 bytes. Setting range: 0001h to 0800h ·ASCII: 2, 048 bytes (2, 048 characters) ·Hexadecimal code: 2, 048 bytes (4, 096 characters)
Processing area number setting Read area start address
Number of read bytes
Response
When the read data is within 250 characters.
Command code X 2 R End code 0 2 0 × × n Read data × × 2 Terminator CR
End code
Indicates the execution result for the command. The end code 00 indicates normal completion. For details on end codes, refer to End code List.
p. 95
Read data Indicates the data read from the Data Carrier. The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code indicate the number of read bytes x 2.
66
RFID System
User's Manual
Section 3 Commands
When the read data is 251 characters or higher. [. . . ] Dispose of the Data Carrier as industrial waste. RFID System
User's Manual
128
Section 6 Appendices
List of ASCII Characters
Left digit Right digit b4 to b1 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111
b8 to b5
0000
1001
0010
0011
0100
0101
0110
0111
1000
1101
1010
1011
1100
1101
1110
1111
Column
0 NUL
1 TC7(DLE)
2 (SP) !/
3 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4 @ A B C D E F G H I J K L M N O
5 P Q R S T U V W X Y Z [ \ ] ^ -
6 ` a b c d e f g h i j k l m n o
7 p q r s t
8
9
10
11
12
13
14
15
Row
0 1 2 3 4 5 6 7 5 9 10 11 12 13 14 15
TC1(SOH) DC1 TC2(STX) TC3(ETX) TC4(EOT) DC2 DC3 DC4
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
TC5(NEQ) TC8(NAK) TC6(ACK) BEL FE0(BS) FE1(HT) FE2(LF) FE3(VT) FE4(FF) FE5(CR) SO SI TC9(SYN) TC10(ETB) CAN EM SUB ESC IS4(FS) IS3(GS) IS2(RS) IS1(US)
u v w x y z { | } DEL
Undefined
Section 6 List of ASCII Characters
Note: Do not use the undefined areas.
RFID System
User's Manual
129
Section 6 Appendices
Degree of Protection
International protection degrees (IP-) are determined by the following tests. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V600
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.