User manual OMRON V670

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON V670. We hope that this OMRON V670 user guide will be useful to you.

Lastmanuals help download the user guide OMRON V670.


Mode d'emploi OMRON V670
Download

You may also download the following manuals related to this product:

   OMRON V670 DATASHEET (1638 ko)

Manual abstract: user guide OMRON V670

Detailed instructions for use are in the User's Guide.

[. . . ] Z148-E1-05 V670 Series Electromagnetic Inductive RFID System USER'S MANUAL Introduction We sincerely appreciate your purchase of the V670 series of the Electromagnetic Induction Type RFID System. The V670 series is fully supported by our cutting-edge technology and vast expertise. This user's manual provides vital information on its operational functions and product performances, and includes full instructions for use. READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. [. . . ] When a preset judgment condition has been met, the three outputs below can be specified. The judgment condition can be specified per output. 3) Responds to RS-232C. The preset operating conditions are stored in nonvolatile memory in the controller. So, you do not need to set them at every power on. 4-6 4-3 Operation Mode <Example of usage> When data is read out of the tag into which destination information has been written, the applicable destination only is detected and the pulse is output, and reading could not be done due to any trouble, an error pulse is output as shown below. Error output Coincidence output Error output Coincidence output Trigger input Trigger input Antenna Tag Fast movement (Synchronization sensor) (Synchronization sensor) · Setting and operation flow Setting of operating conditions Item Execution process OUT1 OUT2 RS-232C Description Communication command: RD Communication mode: RI Outputs OUT1 in tms at data matched. Nil Power ON TRIG input Data read (E) Correct end Data matched(D) Coincidence output pulse Abnormal output pulse Trigger input (IN) Communication process Data matched Communication process Data unmatched Communication process Data matched Coincidence output (OUT1) Abnormal output (OUT2) 4-7 4-4 Operation Parameter Setting In the controller, you can specify the operation parameters (Communication Restriction Time, Character Interval Monitoring Time and Response Delay Time) according to your system to optimize the performance and reliability. Usually, you may use the default values. However, this setting allows you to optimize your system. Those parameters are stored in nonvolatile memory in the controller. So, the parameters are not erased even if the power supply turns off. 4-4-1 Communication Restriction Time In the communication to a tag, if a response cannot be made correctly due to any trouble at the communication after tag detection, "Retry" is executed to send the same command again. By specifying the communication restriction time, retry is repeated until the specified time has passed after the command process starts. Controller Tag Controller Tag Host Controller External input Send Send Retry Send Retry Response Communication restriction time Error 72 In the external trigger system command, command process starts when the command process starts. In the auto system command, command process starts when the tag has been detected. Setting Range 10 to 990 ms. * If the default value is set, "retry" is repeated 9 times. 4-4-2 Character Interval Monitoring Time In the controller, a command is recognized by receiving a termination code of command string sent from a host device. However, if the entire command string cannot be received completely due to any trouble, receiving is monitored for a specified time after the last character is received. Then, a format error (14) is returned. If there is no data any more Host Controller Host Controller External input Termination code Response Character interval monitoring time Error 14 Setting Range 0 to 9999 ms. * The default value is 100 ms. 4-8 4-4 Operation Parameter Setting 4-4-3 Response Delay Time When several controllers are connected to a host device through RS-485 etc. (commercial 232C/485 converter is required), RS-485 switches into receiving after data string is sent. Switching time varies depending on a converter. So, if a response from the controller is fast, the communication cannot be executed correctly. By specifying the Response Delay time, the response start time can be changed. * Actual time from the transmission of command to the start of response is internal process time (a minimum time is 0 ms) of the controller + Response Delay time (specified time). Host Controller Host Controller External input Command Response Internal process time Response Delay time Setting Range 0 to 9999 ms. * The default value is 0 ms. Correct Usage For how to use the operation parameter setting (SP) command, refer to the description of "5-8-6 Parameter Setting (SP)". 4-9 4-5 Memory Check Function By adding a check code to a data in a tag, you can detect a data error arisen from memory rewrite life or unintentional factor. A CRC code of generating polynomial X16 + X12 + X5 + 1 is used as the check code. [. . . ] 4 @ A B C D E F G H I J K L M N O 5 P Q R S T U V W X Y Z [ \ ] ^ _ a b c d e f g h i j k l m n o 6 7 p q r s t u Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined b4~b1 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 Row 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NUL TC1(SOH) DC1 TC2(STX) DC2 TC3(ETX) DC3 TC4(EOT) DC4 TC5(NEQ) TC8(NAK) TC6(ACK) TC9(SYN) BEL FE0(BS) FE1(HT) FE2(LF) FE3(VT) FE4(FF) FE5(CR) S0 S1 TC10(ETB) CAN EM SUB ESC IS4(FS) IS3(GS) IS2(RS) IS1(US) v w x y z { | } ~ DEL Appendix-1 Appendix 2 Order Format List Main unit and system components Name/Shape Controller V670-CD1D-V1 V 7 0 - CD1 D 6 Specifications RS-232 interface 24 VDC power supply Outside dimension: 90 × 66 × 75 mm Model Model V670-CD1D-V1 -- Remarks ID Antenna Outside dimension: 40 × 53 × 23 mm Model V670-H11 -- Antenna Outside dimension: M18 × 43 mm Model V670-H51 -- Antenna Outside dimension: M18 × 47 mm Model V670-H51Q -- Tag Memory capacity: 128 bytes Outside dimension: 40 × 40 × 4. 5 mm Memory capacity: 128 bytes Outside dimension: 8 × 16 × 3. 5 mm Memory capacity: 128 bytes Outside dimension: 8 × 28 × 3. 5 mm 3m 10 m 18 m 28 m Model V670-D13F03 -- Tag Model V670-D13F01 -- Tag Model V670-D13F01H -- Junction cable Model V670-A40 Model V670-A41 Model V670-A42 Model V670-A43 Model CR200H-PRO27 For connection of antenna and controller. Programming console -- PRO27 -- Programming console connecting cable 2m Model V700-P10 A dedicated key sheet comes together. Communication connector Connector plug Model XM2A-0901 One set comes with Model V670-CD1D. Connector hood Appendix-2 Model XM2S-0911 Appendix 3 Protective Structure · Protective Structure Note: IPis classified by a test method below. Check sealing in working environment and operating conditions in advance. IEC IP- (International Electrotechnical Commission) Standards (IEC60529: 1989-11) JEM (Japan Electrical Manufacturers' Association) Standards (JEM1030: 1991) IPComplies with the 1st and 2nd symbols of IEC60529. Protective classification for oil penetration. Class Protection Level Oil retaining type Not affected considerably by oil drops or oil spray in any direction. Any oil drop or oil spray in any direction cannot come in. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V670

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON V670 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag