User manual OMRON V7

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON V7. We hope that this OMRON V7 user guide will be useful to you.

Lastmanuals help download the user guide OMRON V7.


Mode d'emploi OMRON V7
Download

You may also download the following manuals related to this product:

   OMRON V7 QUICK GUIDE (8997 ko)

Manual abstract: user guide OMRON V7

Detailed instructions for use are in the User's Guide.

[. . . ] This greatly eases drive setup by eliminating the need to rotate the motor during autotuning. The result - faster, easier and cheaper installation and commissioning. · Sensor-less vector controller ensures 100% at 0. 5Hz · Compact size available in IP20 or IP65 New features Position control at stop Nominal speed Speed · Silent operation · Programming software: CX-Drive for parameter configuration · CASE (Inverter application software) · PLC option board S >S S · High speed Motion Bus: MECHATROLINK-II (ML-II) · Connectivity: Memobus, Dnet, Profibus, CANopen · New features: - Autotuning - Position control when stopping - Carrier frequency up to 14KHz - Analogue positioning - Improved Up & Down function - PTC input - 2 Motors change function - Free I/O's setting to be used from host controller - Frequency Offsets - New start / stop sequence Time S: Travel distance (blue area) Preferred stop position Standard stop at nominal speed. Stopping with position control. Unexpected stop position Embodying advanced on-board processing, V7 inverters offer unrivalled dynamic control, including fast braking and highprecision positioning at stop. [. . . ] 1000 m 10 to 20 Hz, 9. 8 m/s2 max; 20 to 50 Hz, 2 m/s2 max Frequency inverters Varispeed V7 7 3 Digital operator Data display Indicators (setting/monitor item indicators) FREQUENCY adjuster Operation keys Appearance Data display Name Function Displays relevant data items, such as frequency reference, output frequency, and parameter set values. Sets the frequency reference within a range between 0 Hz and the maximum frequency. 1 Frequency adjuster Frequency reference indicator Output frequency indicator Output current indicator Multi-function monitor indicator Forward/reverse selection indicator Local/remote selection indicator Parameter setting indicator Mode key Increment key Decrement key Enter key RUN key The frequency reference can be monitored or set while this indicator is lit. The output frequency of the inverter can be monitored while this indicator is lit. The output current of the inverter can be monitored while this indicator is lit. The values set in U01 through U10 are monitored while this indicator is lit. The direction of rotation can be selected while this indicator is lit when operating the inverter with the RUN key. The operation of the inverter through the digital operator or according to the set parameters is selectable while this indicator is lit. 2 The parameters in n001 through n179 can be set or monitored while this indicator is lit. 3 Switches the simplified-LED (setting and monitor) item indicators in sequence. Parameter being set will be canceled if this key is pressed before entering the setting. Increases multi-function monitor numbers, parameter numbers, and parameter set values. Decreases multi-function monitor numbers, parameter numbers, and parameter set values. Enters multi-function monitor numbers, parameter numbers, and internal data values after they are set or changed. applicable motor output kW 0. 55 1. 1 1. 5 2. 2 0. 55 1. 1 Inverter model CIMR V7TZ B0P405 B0P705 B1P505 B2P205 40P405 40P705 41P505 42P205 43P005 44P005 Dimensions in mm Figure W H D W1 W2 H1 H2 H3 D1 Weight kg 3. 4 Cooling method Self cooled Fan cooled Self cooled Single-phase 200 V 280 240 142 260 228 165 38 275 44 4. 3 3. 7 4. 2 4. 2 4. 3 3. 7 3. 7 4. 1 4. 1 Fan cooled 4 280 240 142 260 228 165 38 275 44 Three-phase 400 V 1. 5 2. 2 3. 0 4. 0 10 6 Frequency inverters Varispeed V7 IP65 type 0. 55 to 4Kw (with option frame accessory attached) W2 H1 D2 D D1 H W W1 6. 4 H2 H1 2x PG12 3x PG25 Figure 5 Voltage class Max. applicable motor output kW 0. 55 1. 1 1. 5 2. 2 0. 55 1. 1 Inverter Figure model CIMR V7TZ B0P405 B0P705 B1P505 B2P205 40P405 40P705 41P505 42P205 43P005 44P005 5 Dimensions in mm W H D W1 W2 H1 H2 H3 D1 D2 Weight kg 3. 6 Cooling method Self cooled Fan cooled Self cooled Singlephase 200 V 280 240 180 260 228 165 38 275 44 38 4. 5 3. 9 4. 4 4. 4 4. 5 3. 9 3. 9 4. 3 4. 3 Fan cooled Three-phase 400 V 1. 5 2. 2 3. 0 4. 0 280 240 180 260 228 165 38 275 44 38 Frequency inverters Varispeed V7 11 7 Installation Standard connections Thermal overload relay (option) X DC reactor (option) U Short bar +2 R/L1 +1 Braking resistor (option) MCCB R S T ­ B1 B2 Line filter 1* Forward run/stop Reverse run/stop External fault (no contact) S/L2 T/L3 NPN S1 S2 S3 S4 S5 S6 S7 SC PHC PHC PHC PHC PHC PHC PHC PNP 24 V U/T1 V/T2 W/T3 Grounding IM Multifunction input Fault reset Multi-step speed reference 1 Multi-step speed reference 2 JOG command MA MB MC Fault Multi-function output 250 VAC 1 A or less 30 VDC 1 A or less P1 Running Pulse train input Frequency reference 2k P Frequency setter P Shield connection terminal Speed reference RP pulse train (33 kHz max. ) Frequency setting FS power supply (+12 V 20 mA) Speed frequency FR reference 0 to +10 V (20 k) OR FC 4 to 20 mA (250 ) 0V Digital operator frequency setting potentiometer min max CN2 P2 Speed agree PC Multi-function photocoupler output +48 VDC 50 mA or less Housing (type : ZHR-3) VIN IIN GND 0 to 10 V P 4 to 20 mA 0V Multi-function analog input 2* R+ AM R­ MEMOBUS communication RS-485/422 max 19. 2kBPS Terminal resistance (1/2 W. 120 ) AC S+ S­ Frequency meter adjusting potentiometer Analog monitor output P FM 0 TO +10 VDC (2 mA) Pulse monitor output Output (12 VDC frequency 20 mA max. 30 - 70% duty) 1* V7 IP65 types are built-in filter. 2* A housing is required when using the CN2 terminal on the back side of the digital operator. 3G3MV-PCN-CN2) is available for housing on request : shielded wire P : twisted pair shielded wire Shows the following two kinds of connections (factory setting) : · Input signals (S1 to S7) are non-voltage contacts · Sequence connection by NPN transistor (0V common) A +24 V power supply is required for sequence connection by PNP transistor (+24 V common) . 12 12 Frequency inverters Varispeed V7 Main circuit Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 B1, B2 +2, +1 +1, ­ Name AC power supply input Inverter output Braking resistor connection DC reactor connection DC power supply input Grounding Function (signal level) Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter. Do not use T/L3 of the models less than 0. 75 kW for other usage, such as a junction terminal. ) For inverter output For braking resistor connection Remove the short bar between +2 and +1 when connecting DC reactor (option) For power supply input (+1: positive electrode; ­ : negative electrode)* For grounding (grounding should conform to the local grounding code. ) Control Circuit Type No. S1 S2 Digital input signals S3 S4 S5 S6 S7 SC RP Analog input signals FS FR FC 1 (CN2) 2 (CN2) 3 (CN2 Digital output signals MA NC MC P1 P2 PC AM AC R+ RS-485/422 R­ S+ S­ Signal name Multi-function input selection 1 Multi-function input selection 2 Multi-function input selection 3 Multi-function input selection 4 Multi-function input selection 5 Multi-function input selection 6 Multi-function input selection 7 Multi-function input selection Common Speed reference pulse train input Power supply terminal for frequency setting Speed frequency reference Frequency reference common Multi-function analog voltage input Multi-function analog current input Multi-function analog input common NO contact output Contact output Contact output common Photocoupler output 1 Photocoupler output 2 Photocoupler output common Analog monitor output Analog monitor common Communication input (+) Communication input (­) Communication output (+) Communication output (­) For MEMOBUS communication operation by RS-485 or RS-422 communication is available. RS-485/422 MEMOBUS protocol 19. 2 kBPS max. [. . . ] (per one unit) W ­ ­ 70 200 70 200 260 100 260 390 520 780 ­ 70 750 70 750 260 400 260 250 390 150 520 100 780 75 70 40 30 20 No. of used ­ ­ 1 1 1 1 1 1 1 ­ 1 1 1 1 1 1 1 Braking torque % ­ ­ 220 125 125 120 125 115 125 ­ 230 130 125 135 135 135 130 Connectable min. resistance 300 300 200 120 60 60 32 9. 6 9. 6 750 750 510 240 200 100 32 32 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V7

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON V7 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag