User manual OMRON VARISPEED J7 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON VARISPEED J7. We hope that this OMRON VARISPEED J7 user guide will be useful to you.

Lastmanuals help download the user guide OMRON VARISPEED J7.


Mode d'emploi OMRON VARISPEED J7
Download
Manual abstract: user guide OMRON VARISPEED J7DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] with potentiometer 3G3IV-PEZZ8122_ DIN attachment Line filter 3G3IV-PCN329-E Inverter to PC cable 3G3IV-PCN126/326 Digital operator extension cable Varispeed J7 Varispeed J7 351 Specifications Type designation CIMR--J7AZ20P1 Inverter J7 series A: With digital operator (with potentiometer) Max. applicable motor output 0P1: 0. 1 kW 4P0: 4. 0 kW [ ~ "P" indicates a decimal point ] Z: European standard specifications Voltage B: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC Voltage class Model CIMR-J7AZ# Three-phase Single-phase1 20P1 B0P1 0. 12 0. 3 0. 8 20P2 B0P2 0. 25 0. 6 1. 6 200 V single/three-phase 20P4 B0P4 0. 55 1. 1 3 20P7 B0P7 1. 1 1. 9 5 21P5 B1P5 1. 5 3. 0 8 22P2 ­ 2. 2 4. 2 11 24P0 ­ 4. 0 6. 7 17. 5 40P2 ­ 0. 37 0. 9 1. 2 40P4 ­ 0. 55 1. 4 1. 8 400 V three-phase 40P7 ­ 1. 1 2. 6 3. 4 41P5 ­ 1. 5 3. 7 4. 8 42P2 ­ 2. 2 4. 2 5. 5 43P0 ­ 3. 0 5. 5 7. 2 44P0 ­ 4. 0 7. 0 9. 2 Max. applicable motor output kW (HP)2 Output characteristics Inverter capacity kVA Rated output current A Max. [. . . ] 0. 5 s or shorter, continuous operation Protected by thermister Individual level stall prevention can be set during acceleration or constant running, provided/not provided setting available during deceleration. Detected by electronic circuit (fan lock detection) Protected by electronic circuit (operation level is approx. 250% of rated output current) ON until the DC bus voltage becomes 50 V or less, RUN lamp stays ON or digital operator LED stays ON. (Charge LED is provided for 400 V) IP20 Self cooling for 200 V 0, 1. . 0, 75 kW (single-phase) 0, 1. . 0, 4 kW (Three-phase) and for 400 V 0, 2. . 0, 75l kW Cooling fan for 200 V (single-phase), 0. 75 kW. . 4. 0 kW (3-phase) and for 400 V 1, 5. . 4. 0 kW -10 ºC to 50 ºC (non-freezing) 90% RH or less (non-condensing) -20 ºC. . +60 ºC (short-term temperature during trasnportation) Indoor (no corrosive gas, dust, etc. ) Max. 1000 m 10 to 20 Hz, 9. 8 m/s2 max; 20 to 50 Hz, 2m/s2 max Control functions Functionality V/f characteristics Digital inputs Digital outputs Standard functions Display Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time. Varispeed J7 353 Digital operator Digital operator Function display LEDs Data display Selected function is lit (see the functions below). Its data is displayed on data display. Display selection key Switch functions among function display LEDs. Operation key Press to run the motor. The RUN light is ON while running. Enter key Enter data when setting constants. at PRGM mode, data are displayed. Alarm LED Run LED Increment key Increase constant no. or data. Frequency setting volume Set operational frequency with volume. Decrement key Decrease constant no. or data. Stop/Reset key Press to stop the motor. If fault occurs, reset the inverter. FREF FOUT IOUT Output current monitoring MNTR Multi-function monitoring Frequency reference Output frequency setting/monitoring monitoring F/R Operator RUN command FWD/REV selection LO / RE LOCAL/REMOTE selection PRGM Constant no. /data 354 Frequency inverters Dimensions IP 20 type 0. 1 to 4 kW 4­M4 2­M4 8. 5 (0. 34) 8. 5 (0. 34) Figure 1 Figure 2 Voltage class Max. applicable motor output kW 0. 12 0. 25 0. 55 Inverter model CIMR-J7AZ# 20P1 20P2 20P4 20P7 21P5 22P2 24P0 B0P1 B0P2 B0P4 B0P7 B1P5 40P2 40P4 40P7 41P5 42P2 43P0 44P0 Figure 1 Dimensions in mm W 68 H 128 D 70 102 122 W1 56 H1 118 H2 5 Weight kg 0. 5 7. 7 0. 8 0. 9 Cooling method Self cooled 200 V three-phase 1. 1 1. 5 2. 2 4. 0 0. 1 0. 2 Fan cooled 2 108 140 129 154 161 128 70 112 96 128 56 118 1. 3 1. 5 2. 1 1 68 118 5 0. 5 0. 9 Self cooled 200 V single-phase 0. 4 0. 75 1. 5 0. 37 0. 55 1. 1 2 2 108 108 128 129 154 81 99 129 154 96 96 118 5 1. 5 1. 0 1. 1 1. 5 Fan cooled Self cooled 400 V three-phase 1. 5 2. 2 3. 0 4. 0 Fan cooled 140 161 128 2. 1 Varispeed J7 355 Filters Schaffner model 3x200 V 1x200 V 3x400 V 3G3JV-PFI2010-SE 3G3JV-PFI2020-SE 3G3JV-PFI1010-SE 3G3JV-PFI1020-SE 3G3JV-PFI3005-SE 3G3JV-PFI3010-SE 3G3JV-PFI3020-SE Dimensions A 194 169 169 169 169 169 174 B 82 111 71 111 111 111 144 C 50 50 45 50 50 50 50 D 160 135 135 135 135 135 135 E 181 156 156 156 156 156 61 F 62 91 51 91 91 91 120 G 5. 3 5. 5 5. 3 5. 3 5. 3 5. 3 5 H M5 M5 M5 M5 M5 M5 M5 I 25 25 22 25 22 22 28 J 56 96 56 96 96 96 128 K 118 118 118 118 118 118 118 L M4 M4 M4 M4 M4 M4 M4 Drive mounts Output flexes Rasmi model 3x200 V 3G3JV-PFI2010-E 3G3JV-PF2020-E 3G3JV-PFI2030-E 1x200 V 3x400 V 3G3JV-PFI1010-E 3G3JV-PFI1020-E 3G3JV-PFI3005-E 3G3JV-PFI3010-E 3G3JV-PFI3020-E Dimensions W 82 111 144 71 111 111 111 144 H 50 50 50 45 50 50 50 50 L 194 169 174 169 169 169 169 174 X 181 156 161 156 156 156 156 161 Y 62 91 120 51 91 91 91 120 Inverter fixing M5 M5 M5 M5 M5 M5 M5 M5 356 Frequency inverters DIN rail mounting bracket 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B (35 . 1) DIN rail . 1) (35 Four, M4 tap Four, M4 tap 3G3IV-PEZZ08122C Four, M4 tap 3-phase 200 VAC Single-phase 200 VAC 3-phase 400 VAC Inverter CIMR-J7AZ20P1/20P2/20P4/20P7 CIMR-J7AZ21P5/22P2 CIMR-J7AZ24P0 CIMR-J7AZB0P1/B0P2/B0P4 CIMR-J7AZB0P7/B1P5 CIMR-J7AZ40P2/40P4/40P7/41P5/42P2 CIMR-J7AZ43P0/44P0 DIN rail mounting bracket 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C Varispeed J7 DIN rail 357 Installation Standard connections U DC reactor (option) short X bar +2 R/L1 S/L2 T/L3 U/T1 V/T2 +1 - MCCB R S T Forward run/stop Reverse run/stop Multifunction input Fault reset External fault (no contact) Multi-step speed reference 1 Varispeed J7AZ S1 S2 S3 IM W/T3 Grounding MA S4 S5 SC MB Running MC Multi-function output 250 VAC 1 A or less 30 VDC 1 A or less Shield connection terminal Pulse train input Frequency reference FS supply (+12 V 20 mA) P P Frequency setting power Speed frequency reference Speed reference 2 k Frequency setter FR 0 To 10 V (20 k ) or 4 to 20mA (250 ) pulse train (33 kHz max. ) FC or O to 20 mA (250 ) 0V Digital operator frequency setting min max volume AM AC indicates shielded wire. : shows the connection for the following two kinds of sequence input (S1 to S5) signals: no-voltage contact and NPN transistors (0 V common). For a PNP transistor (+24 V common), a 24 V external power supply is necessary. Frequency meter adjusting potentiometer Analog monitor P FM output Output frequency 0 To 10 VDC (2 mA) 358 Frequency inverters Main circuit Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 +2, +1 +1, ­ Name AC power supply input Inverter output DC reactor connection DC power supply input Grounding Function (signal level) Main circuit power supply input (Use R/L1 and S/L2 for single-phase power supply inverter. [. . . ] MTG holes 80 (3. 15) 50 (1. 97) DSPL DATA ENTER RUN MIN MAX STOP RESET Remote digital operator with potentiometer 78 (3. 07) 88 (3. 46) 5 (0. 2) 1. 7 (0. 07) 12. 2 (0. 48) 9. 3 (0. 37) 10. 5 (0. 41) 56 (2. 20) 4-M4 spot facing deep 3. 5 (0. 14) 23. 1 (0. 91) 18. 2 30. 4 (0. 72) (1. 20) 15. 5 (0. 61) Varispeed J7 68 (2. 68) 68 (2. 68) 363 Type Model SI-232/J7 (3G3JV-PSI232J) Description Funtions Another option SI-232/J7C (3G3JV-PSI232JC) is available, the only difference is that this one is removable. 21. 5 (0. 85) RS232 adapter 15. 5 (0. 61) 63(2. 48) 29 (1. 14) 2. 5 19 (0. 1) (0. 75) 8(0. 31 Interface units SI-485/J7 (3G3JV-PSI485J) 16 (0. 63) 12 (0. 47) 4 3. 8(0. 15)=15. 2(0. 6) 13(0. 51) RS485 adapter 63 (2. 48) 29 (1. 14) 8 19 8 (0. 3) (0. 75) (0. 3) Accessories 3G3IV-PCN126 3G3IV-PCN326 3G3IV-PCN329-E Digital operator extension cable SI232/J7 must be connected 1 meter 3 meters PC configuration cable SI232/J7 must be connected B Accessories Type Software Model CX-drive CX-One Description Computer software Computer software Installation Configuration and monitoring software tool for drives. Complete OMRON automation software including CX-drive. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON VARISPEED J7

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON VARISPEED J7 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag