[. . . ] W366-E1-09
SYSMAC
WS02-SIMC1-E
CX-Simulator Ver. 1. 9
OPERATION MANUAL
SYSMAC WS02-SIMC1-E CX-Simulator Ver. 1. 9
Operation Manual
Revised February 2009
Notice:
OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. [. . . ] Refer to 6-1 Outline of Network Communications for details. ) Thus the slave initiation function can be checked by connecting the COM port on the computer to another computer.
Slave initiation Program
Access via No-protocol
No-protocol communications are available for connecting a barcode reader, etc. , allowing to process data read from a barcode reader in more practical way.
5-3-3 Precautions in Using Serial Communications
Using Programmable Terminal via NT Link
Even when connecting a PT via NT Link, the Programming Console function and Device Monitoring function are not available. In addition, use a PT with a version of NT31/631-V2 or higher. When connecting a PT with the previous version, select Host Link as the communications protocol.
FINS Command addressed to Serial Port
In the CX-Simulator's FINS communications, only a command addressed to the CPU Unit is accepted. FINS communications addressed to the serial port of individual Ladder Engines are not available.
Changing Communications Protocol during [Work CX-Simulator]
When the communications protocol has been changed by the CX-Programmer's PLC Setup settings, etc. , be sure to once [Disconnect] and then [Connect] again. The newly set protocol becomes effective after the [Connect].
128
Serial Communications Connection When Serial Communications on the CX-Simulator Become Disabled
Section 5-3
When Serial Communications on the CX-Simulator become disabled, for example, when the RS-232C Port Error Flag (A39204) in the Auxiliary area turns ON while executing serial communications on the CX-Simulator, either press [Reset] button in the [Debug Console], or once [Disconnect] and then [Connect] again.
129
Connecting PT via NT Link
Section 5-4
5-4 Connecting PT via NT Link
The diagram below illustrates how to connect OMRON's Programmable Terminal (PT) via NT Link.
PT
PT
1, 2, 3. . . Set to NT Link (1:N) the communications protocol setting for the Ladder Engine's port used by the CX-Programmer. Only the RS-232C port of the CPU Unit (Unit No. : 00H) can be changed using the CX-Programmer's PLC Setup setting. Otherwise, directly change the corresponding DM values from the PLC memory window, etc. Select [Status] | [Settings] | [Serial communications settings] to display [Serial communications settings] window. Select the Serial port of the Serial Communications Unit to be used, followed by pressing the [Edit] button to display [Serial communications registration] window. Set the Communications Setting to [Actual communications] to select a COM port name.
Note
Do not select a COM port name that overlaps with the one allocated in actual communications or the Serial Data File. Press the [OK] button to exit the [Serial communications registration] window and to return to the [Serial communications settings] window. Confirm the communications settings and the COM port name are identical to the contents set in procedure 5 to press the [OK] button. For the communications settings on the PT, set as Protocol: NT Link (1:N), Unit No. : 0, Communications speed: Standard.
Note
If a COM port used by the PT's support tool overlaps with the one used by the CX-Simulator, downloading may fail in the [Connect] status. After [Disconnect], download by the support tool. After completing setting on the PT, [Connect] to perform actual communications via NT Link.
Note
In the NT Link communications, I/O memory values are read/written from/to the PT halfway during the Ladder Engine's scanning because the communications are executed asynchronously to the Ladder Engine.
130
Examples of Serial Communications Debugging
Section 5-5
5-5 Examples of Serial Communications Debugging
5-5-1 Procedure for Debugging Serial Communications Instructions
1, 2, 3. . . Set the communications settings of serial communications to "-" to debug the portions unrelated to serial communications. Setting] window by [Status] | [Settings] | [Serial Comm. Set the communications settings for all the Serial Communications Units to "-. " 2. Set the communications settings of serial communications to "Messages" to display send messages through actual serial communications. Check the contents of the send messages. Setting] window by [Status] | [Settings] | [Serial Comm. [. . . ] Page 177: Changed information for step 4.
03 04
May 2002 December 2003
263
Revision History
Revision code 05
Date November 2005
06
July 2006
07
July 2007
08 09
June 2008 February 2009
Revised content Contents revised to reflect the upgrade from Version 1. 4 to Version 1. 5, and from Version 1. 5 to Version 1. 6, including the following changes: Added information on CP Series throughout manual. Page v: Added information on DANGER and WARNING indications. Page vii: Added information on upgrade from Ver. Page viii: Added information on CP1H CPU Unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON WS02-SIMC1-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON WS02-SIMC1-E will begin.