User manual OMRON X DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON X. We hope that this OMRON X user guide will be useful to you.

Lastmanuals help download the user guide OMRON X.


Mode d'emploi OMRON X
Download

You may also download the following manuals related to this product:

   OMRON X DATASHEET 2 (486 ko)

Manual abstract: user guide OMRON XDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] The above electrical ratings also apply to the AC voltage. With the reverse-type models (X-10GM@), the normally closed circuits and normally open circuits are reversed. The ratings values apply under the following test conditions: Ambient temperature: 20±2°C Ambient humidity: 65±5% Operating frequency: 20 operations/min Characteristics Operating frequency Insulation resistance Contact resistance Dielectric strength Vibration resistance Shock resistance Durability Degree of protection Mechanical: 240 operations/min Electrical: 20 operations/min 100 M min. (initial value) 1, 500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal parts and the ground, and between each terminal and non-current-carrying metal parts Malfunction: 10 to 55 Hz, 1. 5-mm double amplitude (see note 2) Destruction: 1, 000 m/s2 {approx. [. . . ] M12 × 1 mounting screw Two hexagonal nuts (2 t × 14 width across flats) Two lock nuts (2 t × 15. 6 width across flats) (see note 2) OF max. OP 5. 00 N {510 gf} 1. 12 N {114 gf} 0. 9 mm 5. 5 mm 0. 18 mm 21. 8±0. 8 mm 16. 3 16 dia. Note: 1. Imperfect screw part with a maximum length of 1. 5 mm. Panel Mount Roller Plunger X-10GQ22-B PT 23. 3±0. 25 12. 7 dia. × 4. 8 (see note 1) M12 × 1 mounting screw OP 15. 5 16. 3 16 dia. OP 5. 00 N {510 gf} 1. 12 N {114 gf} 0. 9 mm 3. 6 mm 0. 18 mm 33. 4±1. 2 mm Two hexagonal nuts (3 t × 17 width across flats) (see note 2) Note: 1. Imperfect screw part with a maximum length of 1. 5 mm. Panel Mount Cross Roller Plunger X-10GQ21-B PT 23. 3±0. 25 12. 7 dia. × 4. 8 (see note 1) M12 × 1 mounting screw OP 15. 5 See note 3 OF max. OP 5. 00 N {510 gf} 1. 12 N {114 gf} 0. 9 mm 3. 6 mm 0. 18 mm 33. 4±1. 2 mm Two hexagonal nuts (3 t × 17 width across flats) 16 dia. 16. 3 (see note 2) Note: 1. Imperfect screw part with a maximum length of 1. 5 mm. Leaf Spring X-10GL-B 49. 6±0. 8 FP OP t = 0. 3 (see note 1) 4. 8 (see note 2) OF max. OP 1. 96 N {200 gf} 0. 14 N {14 gf} 1. 6 mm (see note) 2. 3 mm 22. 1 mm 17. 4±0. 8 mm Note: 1. Be sure to use the switch at the rated OT value of 1. 6 mm. General-purpose Basic Switch X F-153 Limit Switches Short Hinge Lever X-10GW21-B 20. 2 17. 4 4. 2+0. 075 -0. 025 +0. 1 4. 36-0. 05 dia. 26. 2 28. 2 R t = 1 (see note 1) OP FP 4. 9 (see note 2) OF max. OP 2. 45 N {250 gf} 0. 31 N {32 gf} 2. 1 mm 1. 7 mm 25. 5 mm 20. 7±0. 8 mm 14. 4 9. 2 25. 4±0. 1 11. 9 49. 2 17. 45±0. 2 +0. 075 4. 2-0. 025 dia. Three vent holes Hinge Lever X-10GW-B 26. 2 20. 2 17. 4 63. 5R t = 1 (see note 1) 4. 9 (see note 2) 14. 4 OP FP OF max. OP 1. 08 N {110 gf} 0. 14 N {14 gf} 4. 8 mm 3. 9 mm 34. 6 mm 21. 1±0. 8 mm Note: 1. Three vent holes Low-force Hinge Lever X-10GW4-B 26. 2 20. 2 17. 4 63. 5R PT 14. 4 OP t= 1 (see note 1) 4. 9 (see note 2) OF max. OP 0. 25 N {25 gf} 0. 05 N {5 gf} 14. 3 mm 4. 8 mm 3. 9 mm 21. 1±0. 8 mm Note: 1. Three vent holes Short Hinge Roller Lever X-10GW22-B 20. 2 26. 2 26. 6R t = 1 (see note 3) 9. 5 dia. × 4 (see note 1) (see note 2) OF max. OP 2. 16 N {220 gf} 0. 34 N {35 gf} 2. 4 mm 1. 7 mm 37. 1 mm 32. 2±0. 8 mm OP FP 17. 4 14. 4 Note: 1. Stainless-steel spring lever Hinge Roller Lever X-10GW2-B 26. 2 48. 5R 20. 2 17. 4 t = 1 (see note 3) 9. 5 dia. × 4 (see note 1) (see note 2) OF max. OP 1. 42 N {145 gf} 0. 21 N {21 gf} 4 mm 3 mm 40. 5 mm 32. 2±0. 8 mm OP 14. 4 FP Note: 1. [. . . ] If it is set to the negative terminal, the Switch will not turn OFF. When using the Switch under an inductive load, the arc suppression capability varies depending on current. If the current becomes 0. 6 to 1. 2 A or of the time constant L/R exceeds 7 ms, be sure to provide an arc suppressor. Since the Switch incorporates a permanent magnet, attention must be paid to the following points: · Avoid mounting the Switch directly onto a magnetic substance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag