User manual OMRON Z300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON Z300. We hope that this OMRON Z300 user guide will be useful to you.

Lastmanuals help download the user guide OMRON Z300.


Mode d'emploi OMRON Z300
Download
Manual abstract: user guide OMRON Z300

Detailed instructions for use are in the User's Guide.

[. . . ] The value per each pixel is then averaged to produce a reliable output, free from flutter influence caused by the object's surface condition. Stable detection and high-speed processing is thus possible with the Z300. CCD makes a difference in measurement of a transparent object. PSD sensor A PSD sensor using diffuse reflection is virtually prevented from performing measurement due to insufficient reflection distribution from the surface. [. . . ] Defined at 1/e2 (13. 5 %) of the density at the light center. Light may, however, be present outside this range and if the reflection factor of the light around the workpiece is high compared to the workpiece, measurement may be affected. Error with respect to the theoretical line representing the displacement output for measurement of OMRON standard SUS blocks. The linearity varies with the type of workpiece. Z300 B-37 Z300 Distance to measurement center 20 mm (with beam cover ±50 mm attached: 16 mm) 3 . Error with respect to the theoretical line representing the displacement output for measurement of OMRON standard quartz glass. The linearity varies with the type of workpiece. Error with respect to the theoretical line representing the displacement output for measurement of OMRON standard white alumina ceramics. The linearity varies with the type of workpiece. ex. Z300-S10 120 mm Digital output ±0. 1 % max. Distance 80 mm 120 mm 80 mm 5 . Displacement conversion value for peak-to-peak of displacement output. These figures are for measurement of OMRON standard quartz glass (mirror reflection mode) or OMRON standard SUS blocks (diffuse reflection) at the measurement center. In magnetic fields, it may not be possible to maintain resolution performance characteristics. These figures are for when the Sensor is connected to the Z300-VC10EV3/VC15EV3, the average number of measurements is 256, and M command RS232C output is used. Displacement conversion value for peak-to-peak of displacement output (for measurement of OMRON standard white alumina ceramic at the measurement center). In strong magnetic fields, it may not be possible to maintain resolution performance characteristics. With the Z300-VC10EV3/VC15EV3, at an average number of measurements of 64. With the Z300-VC10EV3/VC15EV3, at an average number of measurements of 512. 10. Value for measurement with 1 line (high speed) set in CCD Mode. between all DC external terminals and GR terminal (100 VDC Megger, with internal surge absorber removed) NON-VISUAL mode 1000 VAC, 50/60 Hz between all DC external terminals and GR terminal (with internal surge absorber removed) 10 mA max. 1500 Vp-p; Pulse width: 0. 1 µs/ 1 µs; Rising edge: 1-ns pulse 10 to 150 Hz (double amplitude: 0. 1 mm) for 8 min. each in X, Y, and Z directions 200 m/s2, 3 times each in 6 directions Operating: 0 to +50 ° C, Storage: -15 to +60 ° C (with no icing or condensation) Operating and storage: 35 % to 85 % (with no condensation) No corrosive gases Ground the Z300's ground terminal to less than 100 IEC60529 IP20 (in-panel) Controller: ABS 2 manuals, 1 resistor (250 , 1/2 W) General specifications Leakage current Noise resistance Vibration resistance Shock resistance Ambient temperature Ambient humidity Ambient environment Ground Degree of protection Case material Accessories Weight (including packaging) Approx. 700 g) Monitor Item Size Type Resolution Input signal Supply voltage Current consumption Ambient temperature Ambient humidity Weight (including packaging) Accessories Monitor Model 5. 5 inches TFT color liquid crystal 320 × 240 dots NTSC composite video (1. 0 V / 75 ) 20. 4 to 26. 4 VDC Approx. [. . . ] 8 4 9. 5 16. 4 70 25 (15) 25° 69 100 Receiver axis Reference plane Vinyl-insulated round cable 6. 8 dia. Standard length: 2 m Connector B-42 Displacement sensors / Width-measuring Sensors (15) 6. 5 65 25° Z300-S60 Optical axis 45 ±0. 1 38 65 ± 0. 1 Three, M4 holes (0. 5:1) 19 600 5 28 R2 Reference plane 75 65 47 6-R1 Operation indicators 8 21 dia. 9. 5 120 102 88. 75 Receiver axis 57 2 Connector Vinyl insulated round cable 6. 8 dia. Standard length: 500 mm Controller Z300-VC10EV3 Z300-VC15EV3 142. 6 195 Indicators Connector 12. 5 dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON Z300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON Z300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag