User manual OMRON Z5FP-MC10 SETUP MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON Z5FP-MC10. We hope that this OMRON Z5FP-MC10 user guide will be useful to you.

Lastmanuals help download the user guide OMRON Z5FP-MC10.


Mode d'emploi OMRON Z5FP-MC10
Download
Manual abstract: user guide OMRON Z5FP-MC10SETUP MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Cat. No. Z178-E1-01A OMRON Corporation Industrial Automation Company Application Sensors Division Sensing Devices and Components Division H. Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107 Regional Headquarters OMRON EUROPE B. V. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U. S. A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. [. . . ] Use appropriate crimp terminals for M3 screws as shown below. Tighten the terminal screws securely using a torque between 0. 5 and 0. 6 Nm. Terminal Block Connections Recommended Model Manufacturer Forked Model Recommended wire size 1. 31 to 1. 65 mm2 J. S. T. V1. 25-MS3 6. 2mm max. 30 Setup Manual SECTION 3 Connecting External Devices Internal Specifications Use a DC power supply with safety measures against high-voltage spikes (safe extra low-voltage circuits on the secondary side). Input Specifications Input voltage ON current ON voltage OFF current OFF voltage ON delay 12 to 24 V DC ± 10% SECTION 3 5 to 15 mA 8. 8 V max. Internal circuit Terminal Block Connections COM IN + Input terminal Output Specifications Output voltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC ± 10% 45 mA max. 0. 1 mA max. Output termimal Load + COM OUT Setup Manual 31 SECTION 3 Connecting External Devices Terminal Names Control terminal Control terminal Measurement Common Command inputs result outputs for DO 16 to 19 LDOFF DO 16 DO 18 GATE DI 0 DI 2 DI 4 DI 6 SECTION 3 DO 17 DO 19 NC RESET TRIGGER DI 1 DI 3 DI 5 DI 7 Terminal Block Connections DO 0 DO 2 Reset the Measurement Controller result outputs Not connected Control terminal Command inputs Measurement result outputs Not connected Measurement result outputs DO 1 DO 3 DO 5 DO 7 NC DO9 DO 11 DO 13 DO 15 DO 4 DO 6 DO 8 DO 10 DO 12 DO 14 Measurement result outputs Common for DO 0 to 7 Measurement result outputs Common for DO 8 to 15 32 Setup Manual SECTION 3 Connecting External Devices Refer to the separate volume, Operation Manual, for the role of each terminal. · Do not reverse the connections of the signal terminals and COM terminals. · RESET Terminal Do not input the RESET signal immediately after turning the power supply on. When using the RESET signal to synchronize the startup timing, wait at least 1 second after turning the Controller's power supply on before turning the RESET terminal on. SECTION 3 The initial status of the output terminals is off. The terminals may turn on for approximately 0. 5 seconds when the power supply is turned on, however. Make sure that these outputs are not treated as actual signals by external devices. Setup Manual 33 Terminal Block Connections SECTION 3 Connecting External Devices RS-232C Connections The RS-232C port of the Controller can be used to connect input signals such as measurement triggers or output signals such as measurement results. Additionally, data that has been set in the Controller can be backed up in a personal computer. This section explains how to establish an RS-232C connection. Refer to the separate volume, Operation Manual, for details on communication specification settings and I/O formats. In some situations, the RS-232C terminal transmits signals when the power supply is turned on or off, or reset. Make sure that these signals are not treated as actual signals by external devices. SECTION 3 Connector The Controller's RS-232C connector uses a 9-pin D-SUB female connector. The pins are arranged as follows. RS-232C Connections Pin No. 1 2 3 4 5 6 7 8 9 Signal name FG (GND) SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND) Function Protective frame ground Transmission data Reception data Request to send Clear to send Not connected Not connected Not connected Signal ground Use a compatible connector. Recommended Model Manufacturer Plug Hood OMRON Corporation OMRON Corporation Model XM2A-0901 XM2S-0911 34 Setup Manual SECTION 3 Connecting External Devices Wiring The maximum cable length is 15 m. Standard Controller Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND) Pin No. * * * * * Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND) SECTION 3 Wiring for RS/CS Control Controller Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND) Pin No. *Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected. * * * * * Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND) RS-232C Connections Connection Method Align the connector with the socket and press it straight into place, then fix it with the screws on both sides of the connector. · Turn the power supply off when connecting or disconnecting a cable. [. . . ] R Requirements: Same as for other products of that Class. Depends on level of interior radiation. Setup Manual 59 SECTION 4 Appendix Footnotes: Note 1: Based on highest level accessible during operation. Note 2: Required wherever & whenever human access to laser radiation above Class I limits is not needed for product to perform its function. Note 3: Required for protective housings opened during operation or maintenance, if human access thus gained is not always necessary when housing is open. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON Z5FP-MC10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON Z5FP-MC10 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag