Manual abstract: user guide OMRON Z5FP-MC10SETUP MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Cat. No. Z178-E1-01A
OMRON Corporation Industrial Automation Company Application Sensors Division Sensing Devices and Components Division H. Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107 Regional Headquarters OMRON EUROPE B. V. 4, D-71154 Nufringen, Germany Tel: (49)7032-811-0/Fax: (49)7032-811-199 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U. S. A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. [. . . ] Use appropriate crimp terminals for M3 screws as shown below. Tighten the terminal screws securely using a torque between 0. 5 and 0. 6 Nm.
Terminal Block Connections
Recommended Model
Manufacturer Forked Model Recommended wire size 1. 31 to 1. 65 mm2
J. S. T. V1. 25-MS3
6. 2mm max.
30
Setup Manual
SECTION 3 Connecting External Devices
Internal Specifications
Use a DC power supply with safety measures against high-voltage spikes (safe extra low-voltage circuits on the secondary side).
Input Specifications
Input voltage ON current ON voltage OFF current OFF voltage ON delay 12 to 24 V DC ± 10% SECTION 3 5 to 15 mA 8. 8 V max. Internal circuit
Terminal Block Connections
COM IN
+
Input terminal
Output Specifications
Output voltage Load current ON residual voltage OFF leakage current Internal circuit 12 to 24 V DC ± 10% 45 mA max. 0. 1 mA max.
Output termimal Load
+
COM OUT
Setup Manual
31
SECTION 3 Connecting External Devices
Terminal Names
Control terminal Control terminal Measurement Common Command inputs result outputs for DO 16 to 19 LDOFF
DO 16
DO 18 GATE
DI 0
DI 2
DI 4
DI 6
SECTION 3
DO 17 DO 19
NC
RESET TRIGGER DI 1
DI 3
DI 5
DI 7
Terminal Block Connections
DO 0 DO 2
Reset the Measurement Controller result outputs Not connected Control terminal
Command inputs
Measurement result outputs
Not connected
Measurement result outputs
DO 1 DO 3
DO 5
DO 7
NC
DO9
DO 11
DO 13
DO 15
DO 4
DO 6
DO 8
DO 10
DO 12 DO 14
Measurement result outputs
Common for DO 0 to 7
Measurement result outputs
Common for DO 8 to 15
32
Setup Manual
SECTION 3 Connecting External Devices
Refer to the separate volume, Operation Manual, for the role of each terminal.
· Do not reverse the connections of the signal terminals and COM terminals. · RESET Terminal
Do not input the RESET signal immediately after turning the power supply on. When using the RESET signal to synchronize the startup timing, wait at least 1 second after turning the Controller's power supply on before turning the RESET terminal on. SECTION 3
The initial status of the output terminals is off. The terminals may turn on for approximately 0. 5 seconds when the power supply is turned on, however. Make sure that these outputs are not treated as actual signals by external devices.
Setup Manual
33
Terminal Block Connections
SECTION 3 Connecting External Devices
RS-232C Connections
The RS-232C port of the Controller can be used to connect input signals such as measurement triggers or output signals such as measurement results. Additionally, data that has been set in the Controller can be backed up in a personal computer. This section explains how to establish an RS-232C connection. Refer to the separate volume, Operation Manual, for details on communication specification settings and I/O formats.
In some situations, the RS-232C terminal transmits signals when the power supply is turned on or off, or reset. Make sure that these signals are not treated as actual signals by external devices. SECTION 3
Connector
The Controller's RS-232C connector uses a 9-pin D-SUB female connector. The pins are arranged as follows.
RS-232C Connections
Pin No. 1 2 3 4 5 6 7 8 9
Signal name FG (GND) SD (TXD) RD (RXD) RS (RTS) CS (CTS) NC NC NC SG (GND)
Function Protective frame ground Transmission data Reception data Request to send Clear to send Not connected Not connected Not connected Signal ground
Use a compatible connector. Recommended Model
Manufacturer Plug Hood OMRON Corporation OMRON Corporation Model XM2A-0901 XM2S-0911
34
Setup Manual
SECTION 3 Connecting External Devices
Wiring
The maximum cable length is 15 m.
Standard
Controller Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND) Pin No. * * * * * Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND)
SECTION 3
Wiring for RS/CS Control
Controller Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND) Pin No. *Pin numbers on the external device will depend on the device being connected. Refer to the manual for the personal computer or PLC being connected. * * * * * Signal SD(TXD) RD(RXD) RS(RTS) CS(CTS) SG(GND)
RS-232C Connections
Connection Method
Align the connector with the socket and press it straight into place, then fix it with the screws on both sides of the connector.
· Turn the power supply off when connecting or disconnecting a cable. [. . . ] R
Requirements: Same as for other products of that Class. Depends on level of interior radiation.
Setup Manual
59
SECTION 4 Appendix
Footnotes: Note 1: Based on highest level accessible during operation. Note 2: Required wherever & whenever human access to laser radiation above Class I limits is not needed for product to perform its function. Note 3: Required for protective housings opened during operation or maintenance, if human access thus gained is not always necessary when housing is open. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON Z5FP-MC10
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON Z5FP-MC10 will begin.