[. . . ] (100 VAC or 200 VAC, at rated output voltage) 15 ms min. , 20 ms (typical) (100 VAC or 200 VAC, at rated output voltage) 105% to 135% of rated load current, inverted L drop, intermittent, automatic reset Yes (2 units max. For details, refer to the derating curve in Engineering Data. For DC input, parallel operation is possible only for 110 to 350 VDC. ) No Operating: Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage: -25 to 75°C (with no icing or condensation) Operating: 10 to 90% Storage: 10 to 90% DIN track mounting, surface mounting 2. 0 kVAC for 1 min. [. . . ] The ambient temperature is specified for a point 50 mm below the Power Supply. 4 Switching Mode Power Supply ZEN-PA03024 Dimensions Note: All units are in millimeters unless otherwise indicated. ZEN-PA03024 Surface Mounting Holes Two, M4 90 80 45 80 60 60 4. 7 (Sliding: 13 max. ) 70 44 56 Accessories (Order Separately) Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7. 3±0. 15 4. 5 35±0. 3 15 25 10 25 25 1, 000 (500) (See note. ) 10 25 * 27±0. 15 1 15 25 10 25 1, 000 25 10 25 15 4. 5 35±0. 3 27 24 1 29. 2 1. 5 Note: The values shown in parentheses are for the PFP-50N. End Plate PFP-M 10 6. 2 Spacer PFP-S 1. 8 5 16 12 1 50 1. 8 35. 5 35. 3 44. 3 34. 8 11. 5 10 M4 x 8 pan head screw 1. 3 4. 8 16. 5 Switching Mode Power Supply ZEN-PA03024 5 Safety Precautions !CAUTION Minor electric shock may occasionally occur. Do not disassemble the product or touch internal parts. Do not attempt to repair or modify the product. Do not touch the product while power is being supplied or immediately after power is turned OFF. Tighten terminal screws to a torque of 0. 5 to 0. 6 N·m so that they do not become loose. Minor electric shock may occasionally occur during operation. Do not touch the input and output terminals while power is being supplied. The product may occasionally be damaged. Do not allow any clippings or cuttings to enter the product during installation work. This voltage can be also available 10 s after the switch off. Wiring · Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. · Use the following material for the wires to be connected to the Power Supply to prevent smoking or ignition caused by abnormal loads. Always attach pin crimp terminals when using stranded wire. The stripping distance should be 6. 5 mm. Recommended Wire Type Solid wire Stranded wire Pin crimp terminals Cross section 0. 5 to 2. 5 mm2 (Equivalent to AWG20 to AWG14) Cross section 0. 5 to 2. 5 mm2 (Equivalent to AWG20 to AWG14) Dia. : 1. 1 to 2. 3 mm Precautions for Safe Use The following precautions must be observed to ensure safety. · Do not apply more than 100 N force to the terminal block when tightening the terminals. · Be sure to remove the sheet covering the product before turning ON the Power Supply and confirm that nothing is interfering with heat dissipation. Installation Environment · Do not use the Power Supply in locations subject to shocks or vibrations. In particular, install the Power Supply as far away as possible from contactors or other devices that are a vibration source. · Install the Power Supply well away from any sources of strong, high-frequency noise. Mounting · Mounting Direction (Refer to Installation in Engineering Data on page 4. ) Standard Mounting Horizontal Mounting Other Mounting Valid Invalid Invalid Operating and Storage Conditions · When installing the Power Supply, check for any signs that the product or packaging has been struck. If internal parts have been damaged, overvoltages may be output depending on the location of the damage. · Internal parts may occasionally deteriorate or be damaged. Store the Power Supply at a temperature of -25 to 65°C and a humidity of 10% to 90%. · Internal parts may occasionally deteriorate or be damaged. [. . . ] IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZEN-PA03024

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZEN-PA03024 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag