Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON ZG2-DSU. We hope that this OMRON ZG2-DSU user guide will be useful to you.
Lastmanuals help download the user guide OMRON ZG2-DSU.
Detailed instructions for use are in the User's Guide.
[. . . ] Z289-E1-01
ZG2-DSU
Smart Sensor Data Storage Unit
USERS MANUAL
Introduction
Thank you for purchasing the ZG2 Data Storage Unit (ZG2-DSU). This manual provides information regarding functions, performance and operating methods that are required for using the ZG2-DSU. When using the ZG2-DSU, be sure to observe the following: · The ZG2-DSU must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] NG: Logging is performed only when the overall judgment of the CH currently being monitored is NG. PASS: Logging is performed only when the overall judgment of the CH currently being monitored is PASS (OK). (default value)
Logging by All Conditions
Logging is performed by all conditions regardless of judgment result.
FUN mode-[SOURCE]-[LOGGING]-[MEAS]
Setting value
CH
Description
Select the channel of the connected Sensor Controller. When two Controllers are connected, either Sensor Controller may be selected. Select [All].
JUDGE
32
Setting Logging Conditions
ZG2-DSU User's Manual
Logging at a Fixed Cycle
Logging is performed at a specified time cycle.
FUN mode-[SOURCE]-[LOGGING]-[TIME]
Setting value
00:00:00
Description
Specifies the time interval.
2
Logging at Individual Fixed Counts
Logging is performed at a specified count interval.
LOGGING FUNCTIONS
FUN mode-[SOURCE]-[LOGGING]-[POINT]
Setting value
1 - 999, 999
Description
Sets the count interval. (default value: 1)
Specify the Logging Cycle by an External Signal
All data is logged continuously for the duration that the TRIG signal is ON.
Note
·Logging is also performed while function key 1 is held down. ·This key can be used as a substitute for the trigger signal.
FUN mode-[SOURCE]-[LOGGING]-[TRIGGER]
ZG2-DSU User's Manual
Setting Logging Conditions
33
Starting and Ending Logging
The following describes the procedure for starting and ending logging.
Starting Logging
1
FUN TEACH RUN
Switch to the RUN mode.
Available MB Stopping
START
2
Either input the START signal or press the key. Logging is started.
Note
Display details during logging can be changed by the keys. To display the amount of remaining space on a Memory Card To display the measurement value of a task to be logged
Available MB Stopping
START
CH1 TASK1 Stopping
START
CH1 TASK2 Stopping
START
Ending Logging
1
Either input the STOP signal or press the key. Logging ends, and data is saved to the Memory Card.
Important
The Data Storage Unit cannot accept the next logging operation while data is being saved to the Memory Card. Whether or not start of logging can be accepted can be known by the BUSY signal.
Timing charts p. 56
34
Starting and Ending Logging
ZG2-DSU User's Manual
Loading Logging Data to an External Device
There are two ways of loading logging data stored on Memory Card to an external device.
Removing the Memory Card and Copying Logging Data 2
Important
Before removing a Memory Card from the unit, make sure that the CF power LED and access LED are both OFF. If a Memory Card is removed with these LEDs still ON, there is the possibility that data stored on the Memory Card might be lost or the Memory Card or Data Storage Unit might malfunction.
LOGGING FUNCTIONS
Removing Memory Cards p. 20
Copying Logging Data by Serial Communication Commands
Logging data can be copied by input of communication commands from an external device without removing the Memory Card. By using the command for initializing the Memory Card after a copy, data after the copy can be deleted to secure free space on the Memory Card for the next logging operation. Command
CFLOGGET CFPRFGET CFFORMAT
Description
Acquires the measurement values saved on the Memory Card. Acquires the profiles saved on the Memory Card. Initializes the Memory Card.
Refere nce
p. 61 p. 63 p. 70
ZG2-DSU User's Manual
Loading Logging Data to an External Device
35
MEMO
36
Loading Logging Data to an External Device
ZG2-DSU User's Manual
EXTERNAL BANK FUNCTIONS
3
EXTERNAL BANK FUNCTIONS
Saving Bank Data to Memory Cards Transferring Bank Data to the Controller
38 39
Saving Bank Data to Memory Cards
Bank data on Sensor Controllers can be saved on a Memory Card inserted on the Data Storage Unit. 16 sets of bank data on the Sensor Controller are saved to a single file on the Data Storage Unit.
RUN mode-MENU key-[BANK]-[CONTCF]
Setting value
CH File
Description
Selects the channel of the Sensor Controller whose bank data is to be saved. CH2 is not displayed when it is not connected. Selects the bank file number to save to the Memory Card. (BANK0 to 255)
Important
If a file number already containing saved bank settings is selected, those bank settings will be overwritten.
Note
Serial communication commands can be used to save bank data to Memory Cards.
BKCTR2MC command p. 65
38
Saving Bank Data to Memory Cards
ZG2-DSU User's Manual
Transferring Bank Data to the Controller
Bank data stored on Memory Cards can be transferred to the current bank of the specified channel.
RUN mode-MENU key-[BANK]-[CFCONT]
Setting value
File CH
Description
Selects the bank file number to transfer. (BANK0 to 255) Selects the channel of the Sensor Controller at the transfer destination. (1, 2, default value: 1) CH2 is not displayed when it is not connected.
3
EXTERNAL BANK FUNCTIONS
Important
The current settings of the Sensor Controller will be changed. [. . . ] ·Format the Memory Card.
NO MEDIA Insufficient
ZG2-DSU User's Manual
Error Messages and Corrective Actions
77
Glossary
Term
Memory Card CSV file
Explanation
Media for saving and storing logging data. The Data Storage Unit uses compact flash cards. CSV stands for "Comma Separated Values". CSV files are documents containing individual data elements separated by a comma as their delimiter. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZG2-DSU
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZG2-DSU will begin.