User manual OMRON ZS-MDC V2.0

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON ZS-MDC. We hope that this OMRON ZS-MDC user guide will be useful to you.

Lastmanuals help download the user guide OMRON ZS-MDC.


Mode d'emploi OMRON ZS-MDC
Download
Manual abstract: user guide OMRON ZS-MDCV2.0

Detailed instructions for use are in the User's Guide.

[. . . ] Z209-E2-01 ZS-MDC (Ver 2. 0) Smart Sensors Multi-Controller USER'S MANUAL Introduction Section 1 Section 2 Section 3 Section 4 Section 5 , Í, ¶, ß, É `æ 1 Í `æ 2 Í `æ 3 Í `æ 4 Í INTRODUCTION APPLICATION CONSIDERATIONS (Please Read) SECTION 1 FEATURES SECTION 2 INSTALLATION & CONNECTION SECTION 3 SETUP SECTION 4 APPLICATION SETTING EXAMPLES SECTION 5 APPENDIX Section User's Manual Smart Sensors Multi-Controller ZS-MDC Introduction Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] DOWN key: Executes reset · Changes numerical values. Returns to the top of the display customize menu. Applies numerical value settings. MENU key SET key ESC key Hold down for at least two seconds to cancel a zero reset. Returns to the previous menu. When the top menu is displayed, returns to the measured value display. Section 3 SETUP TEACH Mode In this mode, the measured value is displayed at all times on the main display. The threshold values are displayed on the sub-display. Which of the HIGH or LOW threshold values is displayed changes according to the setting of the threshold selector switch. TEACH MODE MENU : TEACHING TEACH MODE : DIRECT IN Displayed alternately Key Operations Key Function keys Not used TEACHING Not used DIRECT IN LEFT key RIGHT key UP key DOWN key Not used Not used Selects the digit in the threshold numerical value. Changes the threshold numerical value. MENU key Registers the measured value when this key is pressed as the threshold value. Not used Not used SET key Applies the newly set threshold value. Cancels the newly set threshold value. ESC key Not used 3-8 ZS-MDC User's Manual Section 3 About Setup List of Setting Items This manual describes only "FUN Mode-[SENSING]" functions unique to the Multi-Controller. Details of other functions are the same as those for the Sensor Controller. Refer to the Sensor Controller Userís Manual. FUN Mode This is the mode for setting the measurement conditions. The items that can be set differ according to which task is selected. When TASK1 is selected, all items including items common to all tasks can be set. When a task other than TASK1 is selected, only items specific to that task can be set. Section 3 SETUP When TASK1 is selected Settings SEL CH CALC Default Value CH FUN Mode SENSING Option/Range Input A to input I Pages p. 3-14 OFF, CH (input A to input I), CALC p. 3-15 (THICK, STEP, K+mX+nY, AVE, MAX-MIN) OFF, ON - FILTER SMOOTH AVERAGE DIFF ON 1 OFF OFF OFF 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 OFF, ON OFF, ON (AUTO, MAN) - OUTPUT HOLD SCALING TYPE OFF, PEAK, BOTTOM, P-P, AVERAGE, SAMPLE EXT, SELF-UP, SELF-DN OFF, ON (T-DELAY, T-TIME) REAL, HOLD -999. 99 to 999. 999 - TRIGGER DELAY 0RESET TYPE OFFSET EXT OFF REAL 0 User's Manual ZS-MDC 3-9 Section 3 About Setup Settings I/O SET JUDGE NO-MEAS HYS TIMER Default Value CLAMP 20 µm OFF Option/Range KEEP, CLAMP 0 to 999. 999 OFF, OFF DELAY (1 to 5000ms), ON DELAY (1 to 5000ms), ONE SHOT (1 to 5000ms) OFF, ON OFF, ON (-999 to 999) OFF, ON OFF, ON OFF, ON OFF, ON TASK (TASK1 to 4, ALL TASK, NONE), FUNC (NORMAL, BANK) TASK1 to TASK4, NONE TASK1 to TASK4, NONE LOG1 to 9(NONE, INPUT A to INPUT I, TASK1 to TASK4) BANK1, BANK2, BANK3, BANK4 (Initializes bank settings. ) (Saves Multi-Controller settings. ) (Initializes Multi-Controller settings. ) Pages - ANALOG FOCUS ADJUST OFF OFF ON ON ON ON TASK TASK1 TASK1 - - INPUT IN0 IN1 IN2 IN3 Section 3 SETUP BANK SYSTEM I/O SET IN OUT ANALOG DIGITAL CHANGE CLEAR SAVE INIT p. 3-16 BANK1 - - INFO CYCLE VERSION 8BIT NONE 1BIT 38400 CR COMPWAY 0 OFF OFF Japanese (Displays the current measurement cycle. ) (Displays the Multi-Controller version. ) 8BIT, 7BIT NONE, ODD, EVEN 1BIT, 2BIT 9600, 19200, 38400, 57600, 115200 CR, LF, CR+LF COMPWAY, NORMAL 0 to 16 OFF, ON OFF, ON Japanese, English - COM (RS-232C) LENGTH PARITY STOP BAUDRAT DELIMIT COM MODE NODE KEYLOCK ZERORST LANGUAG 3-10 ZS-MDC User's Manual Section 3 About Setup When other than TASK1 is selected Settings CALC Default Value CH FUN Mode SENSING Option/Range OFF, CH(input A to input I), CALC (THICK, STEP, K+mX+nY, AVE, MAX-MIN) OFF, ON Page s p. 3-15 FILTER SMOOTH AVERAGE DIFF ON 1 OFF OFF OFF - 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 OFF, ON OFF, ON (AUTO, MAN) - Section 3 SETUP OUTPUT HOLD SCALING TYPE - OFF, PEAK, BOTTOM, P-P, AVERAGE, SAMPLE EXT, SELF-UP, SELF-DN OFF, ON (T-DELAY, T-TIME) REAL, HOLD -999. 99 to 999. 999 - TRIGGER DELAY 0RESET TYPE OFFSET BANK (same as when TASK1 is selected) EXT OFF REAL 0 SYSTEM (same as when TASK1 is selected) User's Manual ZS-MDC 3-11 Section 3 About Setup RUN Mode In the RUN mode, you can customize the details that are displayed in the digital displays. To call the display customize menu, press the MENU key in the RUN mode. RUN mode DIGITAL DOT ECO LCD ON/OFF B. LIGHT CUSTOM Settings Default Value 3 NORMAL ON ON U-OFF D-OFF 0 to 5 NORMAL, ECO, OFF ON, AUTOOFF, OFF ON, AUTOOFF, OFF U-ON/OFF, L-ON/OFF Upper section customize, lower section customize - Option/Range Page s - Section 3 SETUP HELP - - TEACH Mode This is the mode for setting the threshold values TEACH Mode Settings TEACHING DIRECT IN Default Value - Option/Range Page s - 3-12 ZS-MDC User's Manual Section 3 Selecting Tasks Selecting Tasks By assigning expressions to "tasks, " you can process (multi-tasking) multiple logic operations (max. After selecting the task in the task selection menu, make the various settings for the selected task in the respective setup menus. The currently selected task is displayed on the sub-display. Press the ESC key with the FUN Mode-TOP menu displayed. Setting TASK1 TASK2 TASK3 TASK4 Description Selects TASK1 as the destination to store the expression to. Selects TASK2 as the destination to store the expression to. Selects TASK3 as the destination to store the expression to. [. . . ] Judgment outputs are made in the RUN or TEACH mode based on the display values and the threshold, hysteresis width, and timer settings. SmartMonitor Zero This is software that runs on a personal computer. This software enables communication with ZS-MDC, sets the measurement conditions of the Multi-Controller and gang-mounted Sensor Controllers, saves setting data, and displays measurement results as a graph. Section 5 APPENDIX User's Manual ZS-MDC 5-5 Section 5 Specifications and External Dimensions Specifications and External Dimensions Multi-Controller ZS-MDC11/MDC41 (Unit: mm) 52. 50 60 4. 3 3. 90 5-6 ZS-MDC User's Manual 24. 20 32. 90 Section 5 APPENDIX 90 10. 80 13 10 Section 5 Specifications and External Dimensions Item I/O type No. of samples to average Number of mounted Sensor Heads NPNtype ZS-MDC11 ZS-MDC41 PNPtype 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, or 4096 Cannot be connected Connectable version of Sensor Controller Ver2. 0 or later Number of mounted Sensor Controllers Exte Connection method rnal I/F Serial I/O USB2. 0 RS-232C Output Judgment output 3 outputs: HIGH/ PASS/LOW Linear output Max. 9 (The Controller Link Unit is needed for gang-mounting. ) Serial I/O or connector Prewired (standard cable length: 2 m) 1 port, FULL SPEED [12 Mbps], MINI-B 1 port, max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZS-MDC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZS-MDC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag