INTRODUCTION APPLICATION CONSIDERATIONS (Please Read)
SECTION 1 FEATURES
SECTION 2 INSTALLATION & CONNECTION
SECTION 3 SETUP
SECTION 4 APPLICATION SETTING EXAMPLES
SECTION 5 APPENDIX
Section
User's Manual
Smart Sensors Multi-Controller ZS-MDC
Introduction
Introduction
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] DOWN key: Executes reset · Changes numerical values. Returns to the top of the display customize menu. Applies numerical value settings.
MENU key
SET key
ESC key
Hold down for at least two seconds to cancel a zero reset.
Returns to the previous menu. When the top menu is displayed, returns to the measured value display.
Section 3 SETUP
TEACH Mode In this mode, the measured value is displayed at all times on the main display. The threshold values are displayed on the sub-display. Which of the HIGH or LOW threshold values is displayed changes according to the setting of the threshold selector switch.
TEACH MODE MENU : TEACHING
TEACH MODE : DIRECT IN Displayed alternately
Key Operations
Key Function keys Not used TEACHING Not used DIRECT IN
LEFT key RIGHT key UP key DOWN key
Not used Not used
Selects the digit in the threshold numerical value. Changes the threshold numerical value.
MENU key
Registers the measured value when this key is pressed as the threshold value. Not used
Not used
SET key
Applies the newly set threshold value. Cancels the newly set threshold value.
ESC key
Not used
3-8
ZS-MDC
User's Manual
Section 3 About Setup
List of Setting Items
This manual describes only "FUN Mode-[SENSING]" functions unique to the Multi-Controller. Details of other functions are the same as those for the Sensor Controller. Refer to the Sensor Controller Userís Manual.
FUN Mode
This is the mode for setting the measurement conditions. The items that can be set differ according to which task is selected. When TASK1 is selected, all items including items common to all tasks can be set. When a task other than TASK1 is selected, only items specific to that task can be set. Section 3 SETUP
When TASK1 is selected
Settings SEL CH CALC Default Value
CH
FUN Mode
SENSING
Option/Range
Input A to input I
Pages
p. 3-14
OFF, CH (input A to input I), CALC p. 3-15 (THICK, STEP, K+mX+nY, AVE, MAX-MIN) OFF, ON -
FILTER
SMOOTH AVERAGE DIFF
ON 1 OFF OFF OFF
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 OFF, ON OFF, ON (AUTO, MAN) -
OUTPUT HOLD
SCALING TYPE
OFF, PEAK, BOTTOM, P-P, AVERAGE, SAMPLE EXT, SELF-UP, SELF-DN OFF, ON (T-DELAY, T-TIME) REAL, HOLD -999. 99 to 999. 999 -
TRIGGER DELAY 0RESET TYPE OFFSET
EXT OFF REAL 0
User's Manual
ZS-MDC
3-9
Section 3 About Setup
Settings I/O SET JUDGE NO-MEAS HYS TIMER
Default Value
CLAMP 20 µm OFF
Option/Range
KEEP, CLAMP 0 to 999. 999 OFF, OFF DELAY (1 to 5000ms), ON DELAY (1 to 5000ms), ONE SHOT (1 to 5000ms) OFF, ON OFF, ON (-999 to 999) OFF, ON OFF, ON OFF, ON OFF, ON TASK (TASK1 to 4, ALL TASK, NONE), FUNC (NORMAL, BANK) TASK1 to TASK4, NONE TASK1 to TASK4, NONE LOG1 to 9(NONE, INPUT A to INPUT I, TASK1 to TASK4) BANK1, BANK2, BANK3, BANK4 (Initializes bank settings. ) (Saves Multi-Controller settings. ) (Initializes Multi-Controller settings. )
Pages
-
ANALOG
FOCUS ADJUST
OFF OFF ON ON ON ON TASK TASK1 TASK1 -
-
INPUT
IN0 IN1 IN2 IN3
Section 3 SETUP
BANK SYSTEM
I/O SET
IN OUT ANALOG DIGITAL CHANGE CLEAR SAVE INIT
p. 3-16
BANK1 -
-
INFO
CYCLE VERSION
8BIT NONE 1BIT 38400 CR COMPWAY 0 OFF OFF Japanese
(Displays the current measurement cycle. )
(Displays the Multi-Controller version. ) 8BIT, 7BIT NONE, ODD, EVEN 1BIT, 2BIT 9600, 19200, 38400, 57600, 115200 CR, LF, CR+LF COMPWAY, NORMAL 0 to 16 OFF, ON OFF, ON Japanese, English -
COM (RS-232C)
LENGTH PARITY STOP BAUDRAT DELIMIT
COM
MODE NODE KEYLOCK ZERORST LANGUAG
3-10
ZS-MDC
User's Manual
Section 3 About Setup
When other than TASK1 is selected
Settings CALC Default Value
CH
FUN Mode
SENSING
Option/Range
OFF, CH(input A to input I), CALC (THICK, STEP, K+mX+nY, AVE, MAX-MIN) OFF, ON
Page s
p. 3-15
FILTER
SMOOTH AVERAGE DIFF
ON 1 OFF OFF OFF
-
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 OFF, ON OFF, ON (AUTO, MAN) -
Section 3 SETUP
OUTPUT HOLD
SCALING TYPE
-
OFF, PEAK, BOTTOM, P-P, AVERAGE, SAMPLE EXT, SELF-UP, SELF-DN OFF, ON (T-DELAY, T-TIME) REAL, HOLD -999. 99 to 999. 999 -
TRIGGER DELAY 0RESET TYPE OFFSET BANK (same as when TASK1 is selected)
EXT OFF REAL 0
SYSTEM
(same as when TASK1 is selected)
User's Manual
ZS-MDC
3-11
Section 3 About Setup
RUN Mode
In the RUN mode, you can customize the details that are displayed in the digital displays. To call the display customize menu, press the MENU key in the RUN mode. RUN mode
DIGITAL DOT ECO LCD ON/OFF B. LIGHT CUSTOM Settings Default Value
3 NORMAL ON ON U-OFF D-OFF 0 to 5 NORMAL, ECO, OFF ON, AUTOOFF, OFF ON, AUTOOFF, OFF U-ON/OFF, L-ON/OFF Upper section customize, lower section customize -
Option/Range
Page s
-
Section 3 SETUP
HELP
-
-
TEACH Mode
This is the mode for setting the threshold values TEACH Mode
Settings TEACHING DIRECT IN Default Value
-
Option/Range
Page s
-
3-12
ZS-MDC
User's Manual
Section 3 Selecting Tasks
Selecting Tasks
By assigning expressions to "tasks, " you can process (multi-tasking) multiple logic operations (max. After selecting the task in the task selection menu, make the various settings for the selected task in the respective setup menus. The currently selected task is displayed on the sub-display. Press the ESC key with the FUN Mode-TOP menu displayed.
Setting TASK1 TASK2 TASK3 TASK4 Description Selects TASK1 as the destination to store the expression to. Selects TASK2 as the destination to store the expression to. Selects TASK3 as the destination to store the expression to. [. . . ] Judgment outputs are made in the RUN or TEACH mode based on the display values and the threshold, hysteresis width, and timer settings.
SmartMonitor Zero This is software that runs on a personal computer. This software enables communication with ZS-MDC, sets the measurement conditions of the Multi-Controller and gang-mounted Sensor Controllers, saves setting data, and displays measurement results as a graph.
Section 5 APPENDIX
User's Manual
ZS-MDC
5-5
Section 5 Specifications and External Dimensions
Specifications and External Dimensions
Multi-Controller
ZS-MDC11/MDC41
(Unit: mm)
52. 50
60
4. 3
3. 90
5-6
ZS-MDC
User's Manual
24. 20
32. 90
Section 5 APPENDIX
90
10. 80
13 10
Section 5 Specifications and External Dimensions
Item I/O type No. of samples to average Number of mounted Sensor Heads NPNtype
ZS-MDC11
ZS-MDC41 PNPtype
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, or 4096 Cannot be connected
Connectable version of Sensor Controller Ver2. 0 or later Number of mounted Sensor Controllers Exte Connection method rnal I/F Serial I/O USB2. 0 RS-232C Output Judgment output 3 outputs: HIGH/ PASS/LOW Linear output Max. 9 (The Controller Link Unit is needed for gang-mounting. ) Serial I/O or connector Prewired (standard cable length: 2 m) 1 port, FULL SPEED [12 Mbps], MINI-B 1 port, max. [. . . ]