[. . . ] Z263-E1-01
ZX-GT Series
Smart Sensor
USER'S MANUAL
Introduction
Thank you for purchasing the ZX-GT series. This manual provides information regarding functions, performance and operating methods that are required for using the ZX-GT. When using the ZX-GT, be sure to observe the following: · The ZX-GT must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] Confirm the selection.
SUB
FUNCTION SETTINGS
2
Set the ECO mode.
Select [ECO]. Confirm the selection.
SUB
ZX-GT User's Manual
Changing Display Conditions
79
Setting Communication Conditions
RS-232C Communications Specifications
Set the communication specifications for the Controller matched to the communications specifications of external devices. After setting the communications specifications, the Controller must be turned OFF then back ON again to enable the settings.
Setting value
BPS (baud rate) LEN (data length) S. BIT (stop bit) PRTY (parity)
Range
1200, 2400, 4800, 9600, 19200, 38400 (default value: 38400) 7, 8 (default value: 8) 1, 2 (default value: 1) NONE (none), ODD (odd), EVEN (even) (default value: NONE)
HD. FT ST. ET (STX+ETX), CR, CR. LF (CR+LF) (header/footer selection) (default value: CR)
1
Select the special setting.
Select [SPCL]. Confirm the selection.
SUB
2
Set the baud rate.
Select [BPS]. Confirm the selection.
SUB
3
80
Set other items by the same procedure.
Setting Communication Conditions
ZX-GT User's Manual
Setting the Binary Output Cycle
Set the cycle at which binary output is performed. After setting the binary output cycle, the Controller must be turned OFF then back ON again to enable the settings.
Setting value
1 to 500 (ms)
Description
Set the output cycle. (default value: 1) The measurement result is output at the output cycle you set here.
1
Select the special setting.
Select [SPCL]. Confirm the selection.
SUB
3
FUNCTION SETTINGS
2
Set the output cycle.
Select [CYCLE]. Confirm the selection.
SUB
ZX-GT User's Manual
Setting Communication Conditions
81
Special Functions
Zero Reset Memory
Select whether or not to hold the measured value after the zero reset was performed (zero reset level) when the power is turned OFF.
Setting value
OFF ON
Range
Zero reset is canceled when the power is turned OFF. (default value) The zero reset level is saved when the power is turned OFF.
Important
If zero reset memory is set to [ON], the zero reset level will be written in the Controller's nonvolatile memory (EEPROM) each time a zero reset is performed. The EEPROM can be written a maximum of 100, 000 times. Setting the zero reset memory to [ON] can, therefore, use up the life of the memory and lead to malfunctions.
Executing and Canceling a Zero Reset p. 47
1
Select the special setting.
Select [SPCL]. Confirm the selection.
SUB
2
Set zero reset memory.
Select [ZRMEM]. Confirm the selection.
SUB
82
Special Functions
ZX-GT User's Manual
Display during a Zero Reset
Set the zero reset memory function to set the reference value to a value other than 0 (zero).
Setting value
00. 000 to 59. 999 (mm)
Range
Set the reference value. (default value: 00. 000)
1
Select the special setting.
Select [SPCL]. Confirm the selection.
SUB
3
FUNCTION SETTINGS
2
Set the reference value.
Select [ZRDSP]. Confirm the selection.
SUB
ZX-GT User's Manual
Special Functions
83
Key Lock
The key lock function disables all Controller keys. Once the keys have been disabled, no key input will be accepted until the lock is canceled. This function is useful for preventing inadvertent changes to settings. The mode and threshold switches are still enabled even when the key lock function is ON.
Setting the Key Lock
1
Apply the key lock.
Hold down these keys until [OK] is displayed, and then release the keys.
SUB
Canceling the Key Lock
1
Cancel the key lock.
Hold down these keys until [OK] is displayed, and then release the keys.
SUB
84
Special Functions
ZX-GT User's Manual
Switching Banks
The ZX-GT can hold up to two sets of settings, which are called a "bank". Banks can be switched from an external device when changing the device setup.
Important
The following data can be saved in memory as settings of banks. · HIGH and LOW thresholds · Hysteresis width · Number of IC leads, IC lead pitch, IC lead pitch tolerance (IC lead pitch judgment mode) · Number of IC leads, IC lead width, IC lead width tolerance (IC lead width judgment mode) · The first and second specified edges (Specified edge measurement mode)
Setting the Bank Switching Source
Set from where switching of banks is to be instructed.
3
Setting value
KEY I-O
Description
Bank switching is performed by operating the control keys. [. . . ] Limits applicable to products that have emissions in the visible spectrum (400 to 710 nm) for emission durations in excess of 0. 25 second, providing that emissions for other durations and/or wavelengths do not exceed the Class I limits. Class II products are considered hazardous for direct long-term ocular exposure. Limits to products that have emissions in the visible spectrum and that have beams where the total collectable radiant power does not exceed 5 milliwatts. Limits applicable to devices that emit in the ultraviolet, visible, and infrared spectra. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZX-GT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZX-GT will begin.