User manual ONKYO R-805X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ONKYO R-805X. We hope that this ONKYO R-805X user guide will be useful to you.

Lastmanuals help download the user guide ONKYO R-805X.


Mode d'emploi ONKYO R-805X
Download
Manual abstract: user guide ONKYO R-805X

Detailed instructions for use are in the User's Guide.

[. . . ] English FM STEREO/AM TUNER AMPLIFIER Before using R-805X Instruction Manual FM STEREO / AM TUNER AMPLIFIER INPUT ENERGY SAVE CD MD CDR LINE/DVD Connections Preparations VOLUME ACOUSTIC PRESENCE FM AM TAPE STANDBY / ON OFF / 1 / 2 / 3 PHONES DISPLAY MEMORY FM MODE PRESET CLEAR TUNING R-805X Operation FM STEREO / AM TUNER AMPLIFIER INPUT ENERGY SAVE CD MD CDR LINE/DVD VOLUME ACOUSTIC PRESENCE FM AM TAPE STANDBY / ON OFF / 1 / 2 / 3 PHONES DISPLAY MEMORY FM MODE PRESET CLEAR TUNING ACCUCLOCK R-805X Other Information Thank you for purchasing the ONKYO R-805X FM Stereo/AM Tuner Amplifier. Please read this manual thoroughly before making any connection or turning on the power. Follow these instructions to obtain optimum performance and maximum listening enjoyment from your new R-805X. Please retain this manual for future reference. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). [. . . ] Placing the unit behind such doors may prevent proper remote controller operation. · If there is any obstacle between the remote controller and the remote control sensor, the remote controller will not operate. 21 Setting the Clock The "ACCUCLOCK" features an automatic clock adjusting function automatically sets the clock time by means of RDS broadcast signals. · The "ACCUCLOCK" feature is available only on the European model, and only in areas where RDS broadcasts are available. · Adjust the clock as explained in "Setting the clock manually" on page 24 if you are using U. S. or Canadian models or if you are using the unit in the area where RDS broadcasts are unavailable. · It may take about 5 minutes for the time information to be received and displayed after you plug in the power cord. After the clock is initially set, it will be adjusted periodically when the R-805X is in Standby mode (all input source indicators are turned off) or in ENERGY SAVE mode (the ENERGY SAVE indicator is lit). Notes on using the "ACCUCLOCK" function: · Make sure that your FM antenna has been properly connected as explained on page 18. It is strongly recommended that you install an outdoor FM antenna since the FM indoor antenna may not receive RDS broadcasts well enough to allow ACCUCLOCK to function properly. · The clock will display the time in a 24 hour cycle. For example, 5:30 pm will be displayed as "17:30". (You can select a 12 hour cycle display setting. For more information, see page 25. ) · If RDS signals cannot be received, no RDS station will be found. Or if an RDS signal is present but the signal is not strong enough to allow the ACCUCLOCK to automatically set the time, "- -:- -" will lit on the display as shown below. (See page 24. ) Setting the clock automatically (European models only) ACCUCLOCK starts operating as soon as the power cord is plugged in. It then searches for an RDS broadcasting station which regularly sends time signals and waits to receive such time information. Do not operate any buttons until the clock setting is complete. The R-805X retains the clock setting until you unplug the power cord. The following steps describe how to set the clock automatically: 1. "AUTO" flashes slowly on the display. flashes slowly 2. Once an RDS station that sends time signals is detected, the indicator flashes more rapidly. Adjust the clock manually. flashes rapidly 3. Once the time signal is received from the RDS station, "CLOCK ADJUSTED" will scroll on the display. [. . . ] If this happens, unplug the system for at least five seconds. 45 Specifications Amplifier Section Power output 20 watts per channel, min RMS, at 4 ohms, both channels driven 1 kHz, with no more than 0. 6% THD 15 watt per channel, min RMS, at 8 ohms, both channels driven 1 kHz, with no more than 0. 6% THD 2 X 20 watts at 4 ohms, 1 kHz, DIN 2 X 17 watts at 6 ohms, 1 kHz, DIN 2 X 15 watts at 8 ohms, 1 kHz, DIN 2 X 29 watts at 4 ohms, 1 kHz, EIAJ Dynamic power output 2 X 24 watts at 4 ohms 2 X 17 watts at 8 ohms Total harmonic distortion 0. 6% at rated power IM distortion 0. 6% at rated power Damping factor 30 at 8 ohms Input Sensitivity and Impedance TAPE/MD PLAY: 150 mV, 50 kohms LINE IN: 150 mV, 50 kohms Frequency and response 10 to 50, 000 Hz +0 / ­3 dB Tone control ACOUSTIC PRESENCE 1 +4 dB at 82 Hz ACOUSTIC PRESENCE 2 +3 dB at 20. 5 Hz, + 3 dB at 82 Hz ACOUSTIC PRESENCE 3 +3 dB at 20. 5 Hz, + 6 dB at 82 Hz BASS ±8 dB at 100 Hz TREBLE ±8 dB at 10 kHz Signal to noise ratio TAPE: 100 dB (IHF-A) Muting ­ dB Tuner Section Tuning range FM: 87. 9 to 107. 9 MHz (200 kHz steps) (U. S. & Canadian models) 87. 5 to 108. 00 MHz (50 kHz steps) (Other area models) AM: 530 to 1710 kHz (10 kHz steps) (U. S. & Canadian models) 522 to 1611 kHz (9 kHz steps) (Other area models) Usable sensitivity FM: Mono 11. 2 dBf, 1. 0 µV (75 ohms IHF) 0. 9 µV (75 ohms DIN) Stereo 17. 2 dBf, 2. 0 µV (75 ohms IHF) 23. 0 µV (75 ohms DIN) AM: 30 µV 50 dB Quieting sensitivity FM: Mono 17. 2 dBf, 2. 0 µV (75 ohms) Stereo 37. 2 dBf, 20. 0 µV (75 ohms) Capture ratio FM: 2. 0 dB Image rejection ratio FM: 40 dB (U. S. & Canadian models) 85 dB (Other area models) AM: 40 dB IF rejection ratio FM: 90 dB AM: 40 dB Signal to noise ratio FM: Mono 73 dB, IHF Stereo 67 dB, IHF AM: 40 dB Selectivity FM: 50 dB DIN (±300 kHz at 40 kHz Devi. ) AM Suppression Ratio 50 dB Harmonic distortion FM: Mono 0. 2% Stereo 0. 3% AM: 0. 7 % Frequency response FM: 30 to 15, 000 Hz (±1. 5 dB) Stereo separation FM: 45 dB at 1, 000 Hz 30 dB at 100 to 10, 000 Hz Stereo threshold FM: 17. 2 dBf, 2. 0 µV (75 ohms) 46 General Clock precision monthly error: +/-30 seconds (at 25 degrees Celsius) Power supply AC 120 V, 60 Hz AC 230 V, 50 Hz Power consumption 61 W (120 V, 60 Hz) 54 W (230 V, 50 Hz) Dimensions (W X H X D) 205 X 91 X 302 mm 8-1/16" X 3-9/16" X 11-7/8" Weight 3. 4 kg, 7. 5 lbs Specifications and external appearance are subject to change without notice as a result of product improvement. 47 Index to parts and controls Front panel For more information about buttons, turn to the page number in the brackets [ ]. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ONKYO R-805X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ONKYO R-805X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag