Manual abstract: user guide OPTICOM CC-02-4.3

Detailed instructions for use are in the User's Guide.

[. . . ] Temperature Testing of Model CC-02-4. 3 CCTV Camera Prepared by: Weir-Jones Engineering Consultants Ltd. [. . . ] The specifications of the chamber are as follows: Manufacturer: Model: Temperature range: Maximum transition rate: Controller: Envirotronics EVH33-2-705 -73°C to +177°C 7°C per minute manufactured by Micristar The controller for the environmental chamber was calibrated on April 1st, 2005 by TMC Services Inc. in Elk River, Minnesota, using instruments there were traceable to NIST. The calibration certificate of the controller is provided in Appendix 1. Controller Figure 1: Weir-Jones Engineering Consultants Ltd. 1 30140-REP-001-0. wp9 Weir-Jones Engineering Consultants Ltd. In addition to the Controller providing both dry-bulb and wet-bulb temperature readings, two external measurement devices were also used to display the ambient temperature inside the environmental chamber and also the temperature of the unit under test. The two measurement devices were: · · Fluke Model 80TK thermocouple module (S/N 6983158) for the display of the ambient chamber temperature. Fluke Model 80TK thermocouple module (S/N 6983164) for the display of the temperature of the unit under test. The calibration certificates for the Fluke thermocouple modules are also provided in Appendix 1. The outputs from the thermocouple modules were recorded by a HP 34970A data acquisition unit at a sampling rate of one sample every five minutes. 2. 2 Equipment Placement The placement of the three Opticom CCTV cameras within the environmental chamber is shown in Figure 2. An external video monitor is placed outside the chamber in order to view the output from the cameras. Thermocouple to monitor the temperature of the camera casing. [. . . ] 3 30140-REP-001-0. wp9 Weir-Jones Engineering Consultants Ltd. APPENDIX 1: Calibration Certificates Weir-Jones Engineering Consultants Ltd. 4 30140-REP-001-0. wp9 Weir-Jones Engineering Consultants Ltd. 5 30140-REP-001-0. wp9 Weir-Jones Engineering Consultants Ltd. 6 30140-REP-001-0. wp9 Weir-Jones Engineering Consultants Ltd. 7 30140-REP-001-0. wp9 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICOM CC-02-4.3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICOM CC-02-4.3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag