This manual provides specifications for the MDI 1000 2D imager scan engine.
Specifications Manual
Opticon MDI 1000 Specifications Manual
All information subject to change without notice.
Document History
Model Number: Edition: Date: MDI 1000 4b 2008-10-02 Specification Number: Original Spec Number: SS06044 SS06020
Copyright 2008 Opticon. All rights reserved.
This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number
A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Dimensions
Camera module: W 21. 5 mm x D 14. 2 mm x H 11. 8 mm Decoder board: W 25. 2 mm x D 39. 0 mm x H 4. 2 mm
3. 2. Weight
Camera module: 3. 9 grams (max. ) Decoder board: 3. 8 grams (max. )
4. Operating Temperature and Humidity
Temperature: -20 to 55° C Humidity: 5 to 90% RH
4. 2. Storage Temperature and Humidity
Temperature: -25 to 70° C Humidity: 5 to 90% RH
4. 3. Ambient Light Immunity
Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values:
Incandescent light Fluorescent light Sunlight to 10, 000 lx to 10, 000 lx to 100, 000 lx
Conditions Barcode Sample: PDF417 with 0. 254mm resolution
Distance: Angle: Curvature: Power Supply Voltage: 110 mm from the mask of the camera module = 0°, = +15°, = 0° R= 3. 3 V
Scanning performance is guaranteed as long as direct light or a reflection from a light source does not impact the light detection range of the MDI 1000. Note: , and respectively represent pitch, skew and tilt. Please see section 7 for how these values are defined.
7
Opticon MDI 1000 Specifications Manual
5. Absolute Maximum Ratings
Parameter
Power supply voltage (VCC to GND) Input voltage Output voltage
Symbol
VCC VI IO
Value
3. 9 -0. 3 to VCC +0. 3 ±4
Unit
V V mA
5. 2. Electrical Characteristics
VCC =3. 3 V, TA=25° C
Parameter
Range of power supply voltage1 Rush current2 Input voltage H level L level H level Output voltage L level
Symbol
Vcc IPK VIH VIL VOH VOL
Condition
Min
3. 15 2. 4 -0. 3
Typ
3. 3 6 -
Max
3. 45 7 Vcc +0. 3 0. 9
Unit
V A V V V V
IOH = -4 mA IOL = 4 mA
2. 8 -
-
0. 5
5. 3. Consumption Current with Default Settings
When the scan engine is configured to "Prior snapshot ON" and "Snapshot and decoding parallelism ON".
Parameter
Operating current Stand-by current Power-down current
3
Symbol
IOP ISTB ISLP
Min
-
Typ
310 125 25
Max
410 155 50
Unit
mA mA mA
Input connector. Vcc is supplied by a direct-current power of 10 A and is measured using a current probe. If it is necessary to decrease impressed current, please supply the power slowly. 3 When configured with the SLEEP command or power-down mode.
2
1
8
Opticon MDI 1000 Specifications Manual
5. 4. Consumption Current with Standard Scanning Mode
When the scan engine is configured to "Prior snapshot OFF" and "Snapshot and decoding parallelism OFF".
Parameter
Operating current Stand-by current Power-down current
4
Symbol
IOP ISTB ISLP
Min
-
Typ
250 90 10
Max
390 110 25
Unit
mA mA mA
4
When configured with the SLEEP command or power-down mode.
9
Opticon MDI 1000 Specifications Manual
5. 5. Timing
Figure 1: Timing Chart
Conditions Timing Chart
Input Voltage Down peak Peak 3. 3 V 2. 36 V / 1. 00 V fall after 0. 7 ms 2. 7 A during 0. 01 ms after 0. 7 ms
10
Opticon MDI 1000 Specifications Manual
5. 6. Power Mode Transition
Figure 2:Power mode transition
When in Power Down mode, the MDI 1000 automatically enters the power-down state from Power On. When the MDI 1000 is in Power Down mode and the MDI 1000 is switched to a Standby state by sending a CTS signal or AIM/WUPn signal, or there is no event that causes the MDI 1000 to switch to another mode, the MDI 1000 enters Power Down mode after the time-out. If the MDI 1000 enters a power-down state while using USB_VCP as an interface, it may cause defects that affect the operation of a Windows device driver.
11
Opticon MDI 1000 Specifications Manual
6. Laser Scan Specifications
Parameter
Scan method Scan rate Range of readable pixels Center wave length of aiming LED (2 green LEDs) Center wave length of LED for Lighting (4 red LEDs) View angle
Specification
CMOS area sensor (grayscale) 30 1280 (H) x 1024 (V) 527 630 Horizontal: 47 Vertical: 37. 5
Unit
fps pixel nm nm °
6. 2. Imager Output
Item
Image data format Shades of gray Range of output image Resolution of output image Interface of output image Transmission time
Specification
Windows Bitmap, JPEG, TIFF 256, 16, 2 Select in horizontal and vertical scale. Full, 1/2, 1/3, 1/4 RS-232C, USB-VCP USB-VCP (Full speed) RS-232C (115. 2 kbps) Conditions: Shades of gray: 256 Resolution: full About 4 sec About 120 sec
12
Opticon MDI 1000 Specifications Manual
7. Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each section. [. . . ] Barcode Sample:
Resolution: Symbology: Distance: Angle: Curvature: Power Supply Voltage: 0. 254 mm PDF417 110 mm from the mask of the camera module = 0° = 15° = 0° R= 3. 3 V
14. Reliability
MTBF (Mean Time Between Failures) of this product is 50, 000 hours. The estimate of MTBF is based on standard operation of the product within the recommended temperature range and without extreme electronic or mechanical shock.
27
Opticon MDI 1000 Specifications Manual
15. LED Safety
All LED-based products are LED class 1 and are safe under reasonably foreseeable operating conditions. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON MDI 1000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICON MDI 1000 will begin.