[. . . ] Imager Scanner
OPI 2201
The OPI 2201 scanner enables smooth scanning of linear (1D) and 2D symbologies with an autofocus function.
Specifications Manual
Opticon OPI 2201 Specifications Manual
All information subject to change without notice.
Document History
Model Number: Edition: Date: OPI 2201 Initial Release 2008-10-31 Specification Number: Original Spec Number: SS08044
Copyright 2009 Opticon. All rights reserved.
This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number
A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Output Specifications
Parameter
Output voltage Maximum current Power ripple 6. 0 V ±5% 2. 0 A 0. 1 Vp-p max. Optical Specifications
The auto-focus function is enabled after aiming the center of the barcode by the laser light. The aiming operation is activated when pressing the trigger key. The scan engine requires 100ms to capture the image with auto-focus after triggering. Ambient light might affect the detection of the scan field and the time that is required for scanning.
7. 1. Imager Scanning
Parameter
Light-emitting element Emission wavelength Light output Light-emitting element (4 x LEDs)
Specification
Red laser diode 650 ±10 (25° C) 1. 0 or less InGaIP red LED Peak wave length Directivity angle: 2 1/2 (*1) Maximum radiation output (*2)
Unit
-- nm mW -- 645 nm 30° 60° 12600 lx 5040 mcd --
Note
Scanning method Number of effective pixels Frame rate Scan angle
SXGA (1. 3 million pixels) CMOS area sensor (gray scale) SXGA 1280 (column) x 1024 (row) Readable pixel count is 1282 dots (column) ×1026 dots (row) Up to 30 Horizontal: 40 Vertical: 32
MCLK: 48MHz Thermal protection
fps °
*1: The radiation pattern features: 2pcs in 2 types of LED (which have different directivity angles). *2: The figure is measured at 25ºC, IF = 50mA. Class 1M compliant output.
14
Opticon OPI 2201 Specifications Manual
7. 2. Imager Output
Item
Image data format
Specification
Windows Bitmap, JPEG, TIFF
Note
Black spot may appear on the images, however, it does not affect the scanning specifications.
Shades of gray Range of output image Resolution of output image Interface of output image Transmission time
256, 16, 2 Select in horizontal and vertical scale. Full, 1/2, 1/3, 1/4 RS-232C, USB-VCP USB-VCP (Full speed) RS-232C (115. 2 kbps) About 4 sec About 120 sec Shades of gray: 256 Resolution: Full
8. Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions
Ambient temperature and humidity: Ambient light: Angles Background: Room temperature (5 to 35º C) Room humidity (45% to 85% RH) 1000 to 1500 lx (on the barcode surfact) Pitch: = 0°, Skew: = 15°, Tilt: = 0° Barcode = black Space = white Margin = white Background of label = black 0. 9 or higher 6. 0 V Approve the performance when decoding is successful in all ten tests. (Decoding is deemed successful when scanning is successful in 70% of the tests. ) Code 39 (resolution 0. 1 and 0. 127 mm) and JAN codes used for the tests are OPTOELECTRONICS test samples printed by a normal printer. (NW ratio = 1: 1. 25)
PCS (in scanning 2D symbologies) Power supply voltage: Decoding test:
Barcode test sample (1D and 2D)
15
Opticon OPI 2201 Specifications Manual
Test Samples: 1D Symbologies Code 39
Resolution
0. 1 mm 0. 127 0. 254 mm 1. 0 mm Code 39 0. 9
Symbology
PCS
Size (mm)
10 x 9 11 x 10 14 x 10 56 x 30
Digits
4
2
JAN
Resolution
0. 260 mm 0. 260 mm
Symbology
13-digit JAN 8-digit JAN
PCS
0. 9/0. 45 0. 9
Size (mm)
25 x 19 17. 5 x 15. 5
Digits
13 8
Test Samples: 2D Symbologies PDF417
Resolution
0. 254 mm 0. 127 mm Level-4 0. 9
Error Correction
PCS
Size (mm)
26 x 16. 5 13 x 8
Characters
17
QR Code (Model 2)
Resolution
0. 339 mm 0. 127 mm M 0. 9
Error Correction
PCS
Size (mm)
10 x 10 4x4
Characters
44
Data Matrix
Resolution
0. 339 mm 0. 169 mm ECC200 0. 9
Model
PCS
Size (mm)
8x8 4x4
Characters
40
Micro QR
Resolution
0. 212 mm
Error Correction
L
PCS
0. 9
Size (mm)
5x5
Characters
11
16
Opticon OPI 2201 Specifications Manual
8. 1. Print Contrast Signal (PCS)
0. 45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Reflectance of white barReflectance of black bar Reflectance of white bar
Scanning performance may decline if dirt or scratches mar the optical window. Conditions
MRD Distance Barcode test sample (1D & 2D) 32% and higher (With over 70% reflectivity of space and quiet zone. ) 120 mm from the focal plane of the scanner. PDF417 (Resolution: 0. 254 mm, PCS: 0. 45)
8. 2. Minimum Resolution
Resolution
0. 1 mm 0. 127 mm 0. 169 mm 0. 212 mm
Symbology
Code 39 PDF417, QR Code Data Matrix Micro QR
17
Opticon OPI 2201 Specifications Manual
8. 3. Depth of Field The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin.
Figure 3: Depth of field
18
Opticon OPI 2201 Specifications Manual
Symbology
Code 39
Resolution (mm)
0. 1 0. 127 0. 254 1. 0 0. 127 0. 254 0. 127 0. 339 0. 169 0. 339 0. 212
Decode Depth (mm)
15-100 15-155 15-365 90-1450 15-160 30-375 15-40 15-280 15-120 35-275 15-100
PCS
0. 9
PDF417 QR Code Data Matrix Micro QR Code
0. 9 0. 9 0. 9 0. 9
19
Opticon OPI 2201 Specifications Manual
8. 4. Skew Angle and Dead Zone Skew angle: = ±65° 8. 4. 3. [. . . ] JIS C6802: 2005: Class 1M IEC 60825-1+A2: 2001 Class 1M
18. 2. EMC
EN55022 EN55024 VCCI Class B: This is a Class B product, to be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Please install and use the equipment according to the instruction manual. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON OPI 2201
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.