User manual OPTICON OPI 4002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OPTICON OPI 4002. We hope that this OPTICON OPI 4002 user guide will be useful to you.

Lastmanuals help download the user guide OPTICON OPI 4002.


Mode d'emploi OPTICON OPI 4002
Download
Manual abstract: user guide OPTICON OPI 4002

Detailed instructions for use are in the User's Guide.

[. . . ] 2D Barcode Scanner OPI 4002 The OPI 4002 is a 2D barcode scanner that ·provides wireless communication compliant with IEEE 802. 15. 4 between the OPI 4002 and a host system. Specifications Manual Opticon OPI 4002 Specifications Manual All information subject to change without notice. Document History Model Number: Edition: Date: OPI 2002 1A 2006-12-22 Specification Number: Original Spec Number: SS06077 SS06076 Copyright 2006 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon. Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Shows that the scan or transmission was executed normally. Shows that the data could not be transmitted. Shows that the data is being stored in memory. Shows that registration was completed. Buzzer Trrr Pip, Pip, Pip Trrrrrrrrrrr Peeeeeeeeep (Completion of Registration) Pip, Pip, Pip Wireless Connection Green Red Lighting Lighting Shows that registration failed. 9 Opticon OPI 4002 Specifications Manual 6. Imager Scanning Parameter Scanning method Effective pixels Frame rate Aiming LED wavelength (2 green LEDs) Lighting LED wavelength (4 red LEDs) View angle Focal length Specification CMOS area sensor (black and white) 1280 (H) x 1024 (V) 30 527 630 Horizontal: 47 Vertical: 37. 5 85 Unit -- dots fps nm nm ° mm Notes: Refer to chapter 7, "Technical Specifications, " to read about scanning performance. 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity: Ambient light: Light source: Angles: Curvature Background: Room temperature (5 to 35º C) Room humidity (45% to 85% RH) 1000 to 1500 lx (on the surface of a barcode) 3-wavelength inverter fluorescent light = 0°, = +15°, = 0° R= Barcode = black Space = white Margin = white Background of label = black 3. 6 V Approve the performance when decoding is successful in 70% or more of the tests Power supply voltage: Decoding test: 10 Opticon OPI 4002 Specifications Manual 7. 1. Test Samples: 1D Symbologies The size of barcodes does not include quiet zones. 1D Barcode Resolution 0. 254 mm 0. 1 mm 0. 26 mm 0. 26 mm Symbology Code 39 Code 39 13-digit JAN 8-digit JAN PCS 0. 9 0. 9 0. 9 0. 9 Size (mm) 14 x 10 11 x 10 25 x 19 17. 5 x 15. 5 Digits 2 4 13 8 Barcode samples with 0. 127 mm and 0. 26 mm resolution are OPTOELECTRONICS test samples. Other charts are printed by a regular printer. N/W Ratio: Angle: Curvature 1:2. 5 = 0°, = 15°, = 0° R= 7. 2. Test Samples: 2D Symbologies PDF417 Resolution 0. 127 mm 0. 254 mm 0. 339 mm Error Correction Level-4 Level-4 Level-4 PCS 0. 9 0. 9 0. 9 Size (mm) 13 x 8 26 x 16. 5 35 x 22 Characters 17 17 17 Charts are printed by a regular printer. Horizontal to vertical ratio is 3:1 Data Matrix Resolution 0. 169 mm 0. 339 mm Model ECC200 ECC200 PCS 0. 9 0. 9 Size (mm) 4x4 8x8 Characters 40 40 QR Code Resolution 0. 169 mm 0. 339 mm Model M M PCS 0. 9 0. 9 Size (mm) 5x5 10 x 10 Characters 44 44 11 Opticon OPI 4002 Specifications Manual 7. 3. Print Contrast Signal (PCS) 0. 45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Reflectance of white barReflectance of black bar Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window. Minimum Resolution Resolution 0. 1 mm 0. 127 mm 0. 169 mm 0. 169 mm Symbology Code 39 PDF417 QRCode Data Matrix 12 Opticon OPI 4002 Specifications Manual 7. 5. Depth of Field The depth of field is measured from the edge of the optical window. Figure 1: Depth of field Symbology Code 39 PDF417 QR Code Data Matrix Resolution (mm) 0. 1 0. 254 0. 127 0. 339 0. 169 0. 339 0. 169 0. 339 Decode Depth (mm) 55­75 30­105 45­80 25­130 45­75 25­100 45­70 35­95 PCS 0. 9 0. 9 0. 9 0. 9 13 Opticon OPI 4002 Specifications Manual 7. 6. Pitch, Skew, and Tilt Pitch: = ±50° Skew: = ±60° or less Tilt: = 360° or less Figure 2: Pitch, skew, and tilt Conditions Barcode Sample: CODE39 and PDF417 with 0. 254 mm resolution, PCS: 0. 9 Distance: Curvature: 56 mm from the front edge of the scanner R= (The calculation of pitch and tilt angles is based on the skew angle formula being = +15°) Notes When a barcode is printed on glossy paper or a card case, it may cause difficulties in scanning due to the reflection of lighting LEDs. To improve scanning performance under these circumstances, scan the barcode with a scan angle of 15 degrees or with lighting LEDs turned off. When scanning a barcode with lighting LEDs turned off, confirm that there is enough ambient lighting in the room (1000 lx or higher), or scanning performance may decline. Scanning performance may also decline if room light reflects on the barcode surface. 14 Opticon OPI 4002 Specifications Manual 7. 7. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R20 mm. Figure 3: Curvature Conditions Barcode Sample: Symbology: 13-digit JAN, resolution: 0. 26 mm, PCS: 0. 9 mm Distance: Angle: 56 mm from the front edge of the scanner = 0°, =15°, = 0° 15 Opticon OPI 4002 Specifications Manual 8. [. . . ] It does not have a radio station license in Japan. The following activities are prohibited under the Radio Law: Remodeling and disassembly Peeling off the certificate label 15. 7. State of California: Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate. To comply with California Perchlorate Best Practice Regulations and the Law for the Promotion of Utilization of Recyclable Resources (Japan), products that may contain Perchlorate materials should be properly labeled on the exterior of all outer shipping packages and/or in locations that otherwise satisfy the California Perchlorate Best Management Practices. 27 Opticon OPI 4002 Specifications Manual 16. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON OPI 4002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICON OPI 4002 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag