Detailed instructions for use are in the User's Guide.
[. . . ] Barcode Data Collector
OPL 9712
The OPL 9712 data collector uses barcode laser scanning technology and uses Bluetooth for communication.
Specifications Manual
Opticon OPL 9712 Specifications Manual
All information subject to change without notice.
Document History
Model Number: Edition: Date: OPL 9712 1A 2007-02-05 Specification Number: Original Spec Number: SS06071 SS06050
Copyright 2007 Opticon. All rights reserved.
This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number
A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Note: , and respectively represent pitch, skew and tilt. Please see section 8 for how these values are defined.
8
Opticon OPL 9712 Specifications Manual
5. Controls
Item
Controls MPU Clock frequency External memory Flash ROM SRAM LCD DPI Display Backlight Functions Clock Real time clock
Specifications
16-bit CISC CPU 14. 74 MHz 512 KB 512 KB Semi-transparent dot matrix LCD 112 x 64 dpi Installed Clock time, battery power, failure notification, function settings Counts year, month, date, hour, minute of the current time and corresponding to leap years
Remarks
Manufactured by Toshiba
For BIOS/AP For WORK/DATA
6. Main Battery
The main battery is a lithium-ion secondary battery. Nominal capacity: 600 mAh Battery life: rechargeable 300 times
6. 2. Battery Operating Time and Charging Time
Parameter
Backup battery Current consumption Usable time
Specifications
3. 4 mAh lithium-ion battery 1 mA or less 150 mA or less 24 hours or more 50 hours or more At standby When operating
Notes
1 scan/5s Without backlight, with Bluetooth communication 1 scan/5s Without backlight, no communication After main battery discharged
Data hold time
72 hours or more
Note: Battery life may be shorter than specified above when the quality of the battery pack is degraded.
9
Opticon OPL 9712 Specifications Manual
7. Laser Scan Specifications
Parameter
Light-emitting element Emission wavelength Light output Scanning method Scanning speed Scan angle
Specification
Red laser diode 650 ±10 (25° C) 1. 0 or less Bi-directional vibration mirror 100 ±20 Scan angle: 54 ±5 Read angle: 44 (Min)
Unit
-- nm mW -- scans/s ° °
Note: Refer to chapter 8, "Technical Specifications, " to read about scanning performance.
8. Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions
Ambient temperature and humidity: Ambient light: Background: Room temperature (5 to 35º C) Room humidity (45% to 85% RH) 500 to 900 lx Barcode = black Space = white Margin = white Background of label = black
8. 1. Print Contrast Signal (PCS)
0. 45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Reflectance of white barReflectance of black bar Reflectance of white bar
Scanning performance may decline if dirt or scratches mar the optical window. Minimum Resolution
0. 15 mm
10
Opticon OPL 9712 Specifications Manual
8. 3. Depth of Field The depth of field is measured from the edge of the data collector. The scanning range is within the circular arc centered on the scan origin.
365
240
145
75
60
40 35
CLR
WX 9 YZ U 8TV Q 7P RS
3DEF
6M O N
44
52
2 AB C
KL 5J
Sh i f t
M in mu read ing d is tance im
Reso lu t ion 0 . 15 Reso lu t ion 0 . 25
Reso lu t ion 0 . 5 Reso lu t ion 1 . 0
Figure 2: Depth of field
Symbology
Code 39 Code 39 Code 39 Code 39
Resolution (mm)
1. 0 0. 5 0. 25 0. 15
Decode Depth (mm)
60300 35210 35120 3570
PCS
0. 9 0. 9 0. 9 0. 9
Conditions Barcode Sample: OPTOELECTRONICS Test Sample
N/W ratio: Angle: Curvature: 1:2. 5 = 0°, = 15°, = 0° R=
11
4GH I
1
. *. . .
0-
BS
E NT
Opticon OPL 9712 Specifications Manual
Resolution
1. 0 mm 0. 5 mm 0. 25 mm 0. 15 mm
Symbology
Code 39 Code 39 Code 39 Code 39
PCS
0. 9 0. 9 0. 9 0. 9
Quiet Zone
25 mm 18 mm 10 mm 7 mm
Digit
1 3 8 10
Note: dirt or scratches on the mask will degrade scanning performance. Always handle the data collector carefully.
8. 4. Pitch Angle = ±25°
Figure 3: Pitch
Conditions Barcode Sample: OPTOELECTRONICS Test Sample
Distance: Label: 90 mm from the edge of the data collector Pitch, Skew Angle PCS = 0. 9, Resolution = 0. 25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2. 5 Dead Zone, Tilt Angle PCS = 0. 9, Resolution = 0. 26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm Curvature: R = , Skew Angle = +15° (for measuring Pitch Angle and Tilt Angle)
Angle:
12
Opticon OPL 9712 Specifications Manual
8. 4. 2. Skew Angle and Dead Zone Skew angle: = ±50° (Excluding dead zone) Dead zone: = ±8° (There are some areas in which decoding fails due to specular reflection) (Depth of field: Within 90 mm from the minimum scannable distance).
Figure 4: Skew and dead zone
Conditions Barcode Sample: OPTOELECTRONICS Test Sample
Distance: Label: 90 mm from the edge of the data collector Pitch, Skew Angle PCS = 0. 9, Resolution = 0. 25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2. 5 Dead Zone, Tilt Angle PCS = 0. 9, Resolution = 0. 26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm Curvature: R = , Skew Angle = +15° (for measuring Pitch Angle and Tilt Angle)
Angle:
13
Opticon OPL 9712 Specifications Manual
8. 4. 3. Tilt Angle = ±20°
=20 ° =20 °
Figure 5: Tilt angle
Conditions Barcode Sample: OPTOELECTRONICS Test Sample
Distance: Label: 90 mm from the edge of the data collector Pitch, Skew Angle PCS = 0. 9, Resolution = 0. 25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2. 5 Dead Zone, Tilt Angle PCS = 0. 9, Resolution = 0. 26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm Curvature: R = , Skew Angle = +15° (for measuring Pitch Angle and Tilt Angle)
Angle:
14
Opticon OPL 9712 Specifications Manual
8. 5. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R20 mm.
Figure 6: Curvature
Conditions Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0. 9, Resolution = 0. 26 mm, Quiet Zone = 10 mm Distance: Angle: 90 mm from the edge of the data collector Skew Angle = +15°
The scanning range will vary according to the depth of field.
15
Opticon OPL 9712 Specifications Manual
9. Wireless Interface
Bluetooth® is a registered trademark owned by its proprietor and used by OPTOELECTRONICS Co. , Ltd. under license.
Feature
Version 1) Supported protocol stack 1) 2. 0 RF (Radio Frequency Protocol) BB (Base Band Protocol) LM (Link Manager Protocol) L2CAP (Logical Link Control and Adaptation Protocol) SDP (Service Discovery Protocol) RFCOMM (serial port emulation) DUN (Dial-up Network Profile) SPP (Serial Port Profile) 1 to 1 One data collector to one host system (Do not connect multiple data collectors to one host system. ) Master or Slave mode Authentication enabled: These settings can be configured using menu barcodes. [. . . ] Radio Law
The data collector qualifies as radio equipment for low-power radio stations (2. 4 GHz band advanced data communication systems) as specified in the Radio Law 38-24-1. The data collector has obtained the Certification for Construction Design of Specified Radio Equipment. It does not have a radio station license in Japan. The following activities are prohibited under the Radio Law: Remodeling and disassembly Peeling off the certificate label
15. 7. [. . . ]