User manual OPTICON OPR 2001

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OPTICON OPR 2001. We hope that this OPTICON OPR 2001 user guide will be useful to you.

Lastmanuals help download the user guide OPTICON OPR 2001.


Mode d'emploi OPTICON OPR 2001
Download
Manual abstract: user guide OPTICON OPR 2001

Detailed instructions for use are in the User's Guide.

[. . . ] Laser Barcode Scanner OPR 2001 The OPR 2001 is a handheld laser barcode scanner. Specifications Manual Opticon OPR 2001 Specifications Manual All information subject to change without notice. Document History Model Number: Edition: Date: OPR 2001 1A 2007-02-14 Specification Number: Original Spec Number: SS07011 SS06121 Copyright 2007 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon. Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Curvature of Scan Scanning curvature is the maximum difference between the laser scan line and the line between the ends of the laser scan line. · Up to 1. 17° in a vertical direction from the scan origin (mirror motor mirror). · Up to 3. 06 mm when measured at 150 mm from the scan origin. 11 Opticon OPR 2001 Specifications Manual Measurement is done from the center of the laser scan line. Figure 2: Laser scanning tilt and curvature 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity: Ambient light: Background: Room temperature (5 to 35º C) Room humidity (45% to 85% RH) 500 to 900 lx Barcode = black Space = white Margin = white Background of label = black 6. 0 V (RS-232C) / 5. 0 V (USB, Wedge) Approve the performance when decoding is successful in all ten tests. (Decoding is deemed successful when completed in 0. 5 seconds or less. ) Power supply voltage: Decoding test: 7. 1. Print Contrast Signal (PCS) 0. 45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Reflectance of white barReflectance of black bar Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window. Minimum Resolution 0. 127 mm 12 Opticon OPR 2001 Specifications Manual 7. 3. Depth of Field The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin. Figure 3: Depth of field Symbology Code 39 Code 39 Code 39 Code 39 Code 39 Resolution 1. 0 mm 0. 5 mm 0. 25 mm 0. 15 mm 0. 127 mm Decode Depth (mm) 40­500 20­350 20­200 20­100 30­70 PCS 0. 9 0. 9 0. 9 0. 9 0. 9 Conditions Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio: Angle: Curvature: 1:2. 5 = 0°, = 15°, = 0° R= 13 Opticon OPR 2001 Specifications Manual Resolution 1. 0 mm 0. 5 mm 0. 25 mm 0. 15 mm 0. 127 mm Symbology Code 39 Code 39 Code 39 Code 39 Code 39 PCS 0. 9 0. 9 0. 9 0. 9 0. 9 Quiet Zone 25 mm 18 mm 10 mm 7 mm 5 mm Digits 1 3 8 10 4 7. 4. Pitch Angle Scanning performance is guaranteed when = ±35° Figure 4: Pitch 14 Opticon OPR 2001 Specifications Manual 7. 4. 2. Skew Angle and Dead Zone Scanning performance is guaranteed when skew angle: ±50° (Excluding dead zone) Dead zone: = ±8° (There are some areas in which decoding fails due to specular reflection) Figure 5: Skew angle and dead zone 15 Opticon OPR 2001 Specifications Manual 7. 4. 3. Tilt Angle Scanning performance is guaranteed when ±20° Figure 6: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: Label: 70 mm from the front edge of the scanner Pitch, Skew Angle, Dead Zone PCS = 0. 9, Resolution = 0. 25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2. 5 Tilt Angle PCS = 0. 9, Resolution = 0. 26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm Pitch angle: Skew angle: = +15°, Tilt angle: = 0° Tilt angle: Pitch angle: = 0°, Skew angle: = +15° Skew angle, Dead zone: Pitch angle: = 0°, Tilt angle: = 0° R= Angles: Curvature: 16 Opticon OPR 2001 Specifications Manual 7. 5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R = 15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R = 20 mm. Figure 7: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0. 9, Resolution = 0. 26 mm, Quiet Zone = 10 mm Distance: Angle: 70 mm from the front edge of the scanner Skew Angle = +15° 8. Settings and Communication Reading the menu barcodes in section 10. 1 can set the RS-232C interface default. Item Baud rate Start/stop bits Data bits Parity bits Handshaking Flow control time out [U2] setting 9600 bps 1 bit 8 bits No parity No handshake Indefinitely You can change the communication condition using the menu barcode. 17 Opticon OPR 2001 Specifications Manual 8. 1. 2. Signal Level Signal Name I/O RS-232C Level (V) Mark/OFF TxD RxD RTS CTS OUT IN OUT IN -5 to -15 -3 to -15 -5 to -15 -3 to -15 Space/ON +5 to +15 +3 to +15 +5 to +15 +3 to +15 8. 1. 3. Pin Assignment Signal NC TXD RXD --GND --CTS RTS NC FG Pin 1 2 3 4 5 6 7 8 9 SHELL Notes Open (not connected) Connected to pin 6 with jumper cable. Connected to pin 4 with jumper cable. Open (not connected) Shield Connector: D-sub, 9-pin, Female Power supply: DC jack, EIAJ voltage Class 2 18 Opticon OPR 2001 Specifications Manual 8. 1. 4. Interface Circuit Figure 8: Interface circuit 8. 1. 5. Character Format Uses the same format for both sending and receiving. Character Format Figure 9:Character format (same for both sending and receiving) 8. 1. 7. [. . . ] Complies with 21 CFR 1040. 10 and 1040. 11 except for deviations pursuant to laser notice No. Class II laser devices are not considered to be hazardous when used for their intended purpose. Avoid staring into the laser beam. 17. 2. Product Safety EN60950-1: 2001 IEC60950-1: 2001 17. 3. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON OPR 2001

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICON OPR 2001 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag