User manual OPTICON OPR 3001

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OPTICON OPR 3001. We hope that this OPTICON OPR 3001 user guide will be useful to you.

Lastmanuals help download the user guide OPTICON OPR 3001.


Mode d'emploi OPTICON OPR 3001
Download
Manual abstract: user guide OPTICON OPR 3001

Detailed instructions for use are in the User's Guide.

[. . . ] Rugged Handheld Laser Scanner OPR 3001 The OPR 3001 is a rugged handheld laser barcode scanner with protection against dust and splashing water to ensure reliable operation in harsh environments Specifications Manual Opticon OPR 3001 Specifications Manual All information subject to change without notice. Document History Model Number: Edition: Date: OPR 3001 2A 2006-12-27 Specification Number: Original Spec Number: SS06106 SS06080 Copyright 2006 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon. Limited Warranty and Disclaimers PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PRODUCT. Serial Number A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. [. . . ] Electrical Characteristics Parameter Power supply voltage Symbol Min 5. 4 4. 5 -- Typ 6. 0 5. 0 96 90 400 300 35 30 Max 6. 6 5. 5 130 125 600 500 60 55 Unit V V mA mA mA mA mA mA RS-232C Remarks USB and Wedge RS-232C when emitting USB and Wedge when emitting laser RS-232C USB and Wedge RS-232C USB and Wedge Operating current IOP -- -- Rush current IPEEK -- -- Stand-by current IPRE -- Conditions: · · · Connect 1 resistance to a power supply line in series and measure the current by the voltage between both ends of resistance. Power supply voltage is measured at a connector terminal area. The current value depends on the host computer to which the device is connected. 9 Opticon OPR 3001 Specifications Manual 6. Laser Scan Specifications Parameter Light-emitting element Emission wavelength Light output Scanning method Scanning speed Scan angle Specification Red laser diode 650 ±10 (25° C) 1. 0 or less Bi-directional scanning 100 ±20 Scan angle: 54 ±5 Read angle: 44 (Min) Unit -- nm mW -- scans/s ° ° mm Auto-trigger IR detection area 40 Notes: Refer to chapter 15, "Trigger and Read Options, " to read about the scan modes. Refer to chapter 7, "Technical Specifications, " to read about scanning performance. Tilt of Laser Scan Line Laser scanning tilt is the vertical difference between both ends of a laser scan line. Measure it in the middle of the laser scan line. Maximum tilt between both ends of laser scan line: Less than 1. 2° upward tilt from the scan origin. Maximum of 3. 1 mm when measured at a point 150 mm away from the scan origin. (The skew angle of this measurement was zero degrees. ) 10 Opticon OPR 3001 Specifications Manual 6. 1. 2. Curvature of Scan Maximum gap between the straight line connecting both ends of the laser scan line and the actual laser scan line: Less than 1. 27° curvature from the scan origin. Maximum of 3. 3 mm curvature when measured at a point 150 mm away from the scan origin. (The skew angle of this measurement was zero degrees. ) · Measurement was done from the center of the scan origin. Figure 2: Laser scanning tilt and curvature 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity: Ambient light: Angles: Background: Room temperature (5 to 35º C) Room humidity (45% to 85% RH) 500 to 900 lx Omni-scanning mode: Pitch: = 0°, Skew: = 0­10°, Tilt: = 0° Mobile mode: Pitch: = 0°, Skew: = 0°, Tilt: = 0° Barcode = black Space = white Margin = white Background of label = black 6. 0 V (RS-232C) / 5. 0 V (USB and Wedge) Approve the performance when decoding is successful in all ten tests. (Decoding is deemed successful when completed in 0. 5 seconds or less. ) Power supply voltage: Decoding test: 11 Opticon OPR 3001 Specifications Manual 7. 1. Print Contrast Signal (PCS) 0. 45 or higher (over 70% of reflectivity of space and quiet zone). PCS= Reflectance of white barReflectance of black bar Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window. Depth of Field The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin. Figure 3: Scan area and resolution (in mm) 12 Opticon OPR 3001 Specifications Manual Symbology Code 39 Code 39 Code 39 Code 39 Code 39 Resolution 1. 0 mm 0. 5 mm 0. 25 mm 0. 15 mm 0. 127 mm Decode depth (mm) 30­590 10­360 10­200 10­90 20­60 PCS 0. 9 0. 9 0. 9 0. 9 0. 9 Conditions: Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio: Angle: Curvature: 1:2. 5 = 0°, = 15°, = 0° R= Resolution 1. 0 mm 0. 5 mm 0. 25 mm 0. 15 mm Symbology Code 39 Code 39 Code 39 Code 39 PCS 0. 9 0. 9 0. 9 0. 9 Quiet Zone 25 mm 18 mm 10 mm 7 mm Digit 1 3 8 10 13 Opticon OPR 3001 Specifications Manual 7. 4. Pitch Angle = ±35° 35° 35° Figure 4: Pitch angle 14 Opticon OPR 3001 Specifications Manual 7. 4. 2. Skew Angle and Dead Zone Skew angle: = ±50° (Excluding dead zone) Dead zone: = ±8° (There are some areas in which decoding fails due to specular reflection) Figure 5: Skew angle and dead zone 15 Opticon OPR 3001 Specifications Manual 7. 4. 3. [. . . ] JIS C6802: 2005: Laser class 2 IEC 825-1/EN 60825-1: Laser class 2 FDA CDRH Laser class II. Complies with 21 CFR 1040. 10 and 1040. 11 except for deviations pursuant to laser notice No. Class II laser devices are not considered to be hazardous when used for their intended purpose. Avoid staring into the laser beam. 17. 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON OPR 3001

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICON OPR 3001 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag