User manual OPTICON UNIVERSAL MENU BOOK
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OPTICON UNIVERSAL MENU BOOK. We hope that this OPTICON UNIVERSAL MENU BOOK user guide will be useful to you.
Lastmanuals help download the user guide OPTICON UNIVERSAL MENU BOOK.
Manual abstract: user guide OPTICON UNIVERSAL MENU BOOK
Detailed instructions for use are in the User's Guide.
[. . . ] Set up your personal configuration
bar code configuration and commands manual
OPTICON Universal menu book
Set up your personal configuration
bar code configuration and commands manual
Universal menu book
ver. 12 © December 2009 Ui
OPTICON Universal menu book
CAUTION: This information is subject to change without prior notice. Copyright 2006, Opticon Sensors Europe B. V. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon Sensors Europe.
LIMITED WARRANTY AND DISCLAIMERS Under all circumstances this manual should be read attentively, before installing and or using the product. [. . . ] Pharmaceutical if possible Not check CD
Check CD
OPTICON Universal menu book
SET D8 D9 D1 D0 DA DB 8D 8E +M +L END
_ZZ_ _D8_ _D9_ _D1_ _D0_ _DA_ _DB_ _8D_ _8E_ _+M_ _+L_ _ZZ_
Not transmit CD
Transmit CD
Not transmit ST/SP
Transmit ST/SP Not transm. Pharm. Code Minimum 3 digits
Minimum 1 digit
Disable concatenation
Enable concatenation
U54
OPTICON Universal menu book
3. 3. 5. Options for Codabar Codabar (NW7): Codabar (NW7) is a variable length symbology with an optional check digit and printable start/ stop characters. The next characters are supported: · the digits 0 upto 9 · the characters - $: / . + · start/stop characters are A, B, C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters. ABC-Code: The ABC code is an acronym for American Blood Commission. This code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D. CX-Code: The CX-Code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not transmitted. Options for Codabar: · enable ABC code concatenation · enable CX code concatenation · enable check digit check · disable transmission of the check digit · disable transmission of start/stop · selection of start/stop character translation · selection of minimum number of data characters · enable library space (CLSI) insertion
Fig. Options for Codabar
Codabar start char. data (1 or more char. ) check digit stop char.
Fig. Options for Codabar
ABC Code start char. data (1 or check data (1 or check stop more char. ) digit more char. ) digit char.
3
Code options
Fig. Options for Codabar
CX Code start char. data (1 or check data (1 or check stop more char. ) digit more char. ) digit char.
U55
OPTICON Universal menu book
Space insertion: This option inserts spaces in position 2, 7, 13, of the data string for use in library systems. ST/SP translation: This option enables the translation and transmission of the start and stop characters. Thus if the option ST/SP: abcd/tn*e is chosen, the start character is converted to lower case, e. g. from A, B, C or D to a, b, c, or d respectively and the stop character is converted from A, B, C or D to t, n, *, or e respectively. The next figure shows the resulting format for these options with a Codabar label using A and B as start and stop characters and 1 2 3 4 5 6 as data characters. [. . . ] VCP: An acronym for Virtual Communications Port. This will emulate the RS232 port for the USB interface.
U135
OPTICON Universal menu book
C. EXAMPLE CODES
Example C. 01 UPC-A UPC-A
0
71589
81230 8
UPC-A +2
34
UPC-A +5
98765
0
23569
27002
8
7
49659
02209 3
Example C. 02 UPC-E UPC-E UPC-E1
0
123456
default data: 1234565
5
1
234567
0
default data: 2345670
UPC-E +2
22
UPC-E1 +2
90
0 213224
0
1 657832 6
default data: 213224022
default data: 657832690
UPC-E +5
56789
UPC-E1 +5
32418
0 654321 7
default data: 654321756789
1 098765 0
default data: 098765032418
U136
OPTICON Universal menu book
Example C. 03. EAN-13 and EAN-8 EAN-13 (ISBN) EAN-8
9 780131 103627
6537
8823
ISBN data: 0131103628
EAN-13 +2
12
EAN-8 +2
23
8 710841 090246
5638
2662
EAN-13 +5
02904
EAN-8 +5
06331
8 710841 030181
1055
7778
Appendix
Example C. 04. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OPTICON UNIVERSAL MENU BOOK Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OPTICON UNIVERSAL MENU BOOK will begin.