Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OREGON SCIENTIFIC WMS801. We hope that this OREGON SCIENTIFIC WMS801 user guide will be useful to you.
Lastmanuals help download the user guide OREGON SCIENTIFIC WMS801.
Manual abstract: user guide OREGON SCIENTIFIC WMS801
Detailed instructions for use are in the User's Guide.
[. . . ] Complete Regional Weather Station with MSN® Direct Weather Data Service Model: WMS801 USER MANUAL
Complete Regional Weather Station with MSN® Direct Weather Data Service Model: WMS801 USER MANUAL CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Back View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Force a signal search.
Insert batteries matching the polarity + and -. Press RESET after each battery change.
NOTE For longer lasting use, the AC adapter should be the unit's main source of power. 6
To force a search for the signal: · Press and hold IN / REG. The unit will search for a signal for 15 minutes. If the radio signal is weak, it can take up to 24 hours to get a valid signal reception. NOTE Signals from household devices such as doorbells, electronic garage doors, and home security systems may cause temporary reception failure. This is normal and does not affect general product performance. The reception will resume once the interference ends. Overlapping coverage In areas of overlapping city data coverage, the unit will automatically select data from the tower it gets the best reception from. You may be in an area where your Weather Station can pick up signals from multiple cities. To scan for a different city: · Press and hold IN / REG. · "Scanning" displays when the Weather Station searches for an MSN Direct radio station. To see the city where the Weather Station is receiving data from: 1. Press SELECT until is shown in the Clock area. Press and hold MODE.
CHANGE DISPLAY / SETTING Use the SELECT button to navigate between different Areas, with appearing on the display in the Area that is selected: · Clock / Alarm / Calendar Area · UVI / Barometer / Rainfall Area · Temperature / Humidity / Comfort Level Area 1. Most Areas have alternate display options e. g. Clock / Alarm or UVI / Barometer / Rainfall). Press MODE to switch options, or ALARM to switch between clock and alarm. Press and hold MODE for 2 seconds to enter setting mode. (Press and hold UP or DOWN to quickly scroll through the values. ) 5. 7
CLOCK RECEPTION
This product is designed to synchronize its calendar clock automatically when it receives the MSN Direct service. Reception signal status:
TIME IS SYNCHRONIZED TIME IS NOT SYNCHRONIZED
· Calendar To manually set the clock: (You only need to set the clock and calendar if you have disabled the clock radio reception. ) Press SELECT to navigate to the Clock Area. [. . . ] Images not drawn to scale.
14
TROUBLESHOOTING
PROBLEM Barometer SYMPTOM Strange readings REMEDY Set measurement unit by pressing mb / inHg in the battery compartment Change language (see Clock / Calendar section) Disable clock signal reception and set the clock manually (see Clock Reception section) 1. Manually activate clock signal reception Temp Shows "LL" or "HH" The temperature is outside the display range of the unit If the adapter is plugged in and out in quick succession, the unit stores a small amount of power for a short period of time
SPECIFICATIONS
Unit dimensions (L x W x H) Weight without batteries TEMPERATURE °C or °F Indoor range Outdoor range Resolution Comfort range 263 x 127 x 150 mm (10. 35 x 5. 0 x 5. 91 inches) 576 grams (1. 27lbs) -5°C to 50°C (23°F to 122°F) -62°C to 78°C (-80°F to 173°F) 1°C (2°F) 20°C to 25°C (68°F to 77°F) Min / Max
Calendar
Strange date / month
Clock
Cannot adjust clock
Cannot auto-synch
LCD screen
Displays unclearly for a short time once it has been turned off
Memory RAINFALL In/hr Regional rainfall range 0-2. 5 inches (0-63 mm) WIND SPEED Miles per hour or Kilometers per hour Regional wind speed range 0-254 mph (0-409 kmh) RELATIVE HUMIDITY % Indoor range 25% to 95% Outdoor range 25% to 100% Resolution 1% Comfort range 40% to 70% Memory Min / max BAROMETER mb / hPa or inHg Regional pressure range 0 to 1935 mb Resolution (0 to 655. 34 inHg) WEATHER 1 mb (0. 03 inHg) Display Sunny (day / night), partly cloudy (day / night), cloudy, rainy, snowy, thunder, dust, fog, haze, smoke, windy, frigid
15
ABOUT OREGON SCIENTIFIC
CLOCK Synchronization Clock display Hour format Calendar Dual alarm Auto or disabled HH:MM:SS 12 / 24hr DD/MM or MM/DD; 2-minute beep or melody sound (5 melodies available); high / low volume and 8-minute snooze 6V AC adapter 4 x UM-3 (AA) 1. 5V
Visit our website (www. oregonscientific. com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as frequently asked questions and customer downloads. We hope you will find all the information you need on our website, however if you're in the US and would like to contact the Oregon Scientific Customer Care department directly, please visit: www2. oregonscientific. com/service/support OR call 1-800-853-8883. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC WMS801
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC WMS801 will begin.