User manual OREGON BAR339DPU

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OREGON BAR339DPU. We hope that this OREGON BAR339DPU user guide will be useful to you.

Lastmanuals help download the user guide OREGON BAR339DPU.


Mode d'emploi OREGON BAR339DPU
Download
Manual abstract: user guide OREGON BAR339DPU

Detailed instructions for use are in the User's Guide.

[. . . ] 6 Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Weather Forecast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Projection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] NOTE Batteries should not be exposed to excessive heat such as sunshine or fire. A sensor channel has been found and logged on No sensor found NOTE After every sensor initialisation, the main unit may take up to 30 minutes to receive the time from the sensor. Secure the sensor in the desired location using the wall mount hole or double sided adhesive tape. REMOTE SENSOR INSTALLATION 1. (RTHN318D only) Insert the battery, matching the polarities (+ / -). Press and hold SEARCH on main unit to initiate search and start receiving time and temperature data from the sensor. 4 BAR339DP_M_EN_R6. indd 4 6/18/08 12:30:50 PM NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. CLOCK CLOCK RECEPTION This product is designed to synchronize its clock automatically with a clock signal received from provided remote sensor. To enable / disable signal reception: Press and hold to enable or to disable signal reception. If the signal is weak, it can take up to 24 hours to get a valid signal. Clock signal reception indicator: STRONG SIGNAL WEAK / NO SIGNAL For best results: · Place the sensor within 30 m (100 ft) of the main unit. · Place the sensor out of direct sunlight and moisture. · Position the sensor so that it faces the main unit, minimizing obstructions such as doors, walls and furniture. · Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects. · Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. NOTE Clock reception is dependent on the successful transmission of data from remote sensor. If is displayed, press RESET on sensor and press and on the main unit and ensure sensor successfully logged. 5 6/18/08 12:31:03 PM has been BAR339DP_M_EN_R6. indd 5 EN EN MANUALLY SET CLOCK To set the clock manually, disable the clock signal reception first. The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (month ­ day / day ­ month), month, day and language. BAR339DP: Time zone offset sets the clock +/- 23 hours from the received clock signal time. NOTE If you enter + 1 in the time offset setting, this will give you your local time plus one hour. If you are in the US (BAR339DPA only) set the clock to: 0 for Pacific time +2 for Central time +1 for Mountain time +3 for Eastern time 3. Press ALARM again to turn alarm on / off. To silence the alarm: · Press SNOOZE to silence it for 8 minutes OR · Press any key to turn the alarm off and activate it again after 24 hours. WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius with a 75% accuracy. Main unit Projector Sunny Partially Cloudy Cloudy Rainy Snowy 6 6/18/08 12:31:20 PM NOTE The language options are English (E), Spanish (S), Italian (I), French (F), German (D), and Russian (R). [. . . ] NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer. COUNTRIES RTTE APPROVAL COMPLIED All EU countries, Switzerland CH and Norway N ABOUT OREGON SCIENTIFIC Visit our website (www. oregonscientific. com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: www2. oregonscientific. com/service/support. asp For international inquiries, please visit: www2. oregonscientific. com/about/international. asp FCC STATEMENT This device complies with Part 15 of the FCC Rules. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON BAR339DPU

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON BAR339DPU will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag