[. . . ] 6.
LCD display LED status indicator Wall mount hole RESET hole CHANNEL switch Battery compartment
GETTING STARTED SOLAR PANEL
This product uses a 600mAH rechargeable battery which should be charged via the solar panel. For the battery's first charge, it is strongly advised to charge it for at least 12 hours by lifting and positioning the solar panel in such a way that it faces sunlight directly.
When the rechargeable battery is nearly flat, the LED indicator on the main unit and will flash. Expose the solar panel directly to sunlight for approximately 5 to 6 hours to charge the battery. [. . . ] You may need to experiment with various locations to get the best results.
CLOCk AND CALENDAR NOTE If optional sensors are installed:
· · clock and calendar display will be replaced by temperature/humidity readings. press to toggle between clock and temperature/ humidity display, or calendar and temperature/humidity display.
NOTE Use alkaline batteries for longer usage and consumer
grade lithium batteries in temperatures below freezing. To search for a sensor: Press and hold + at the same time. The remote sensor reception icon will show the following status:
CLOCk RECEPTION
This product is designed to synchronize its clock automatically with a clock signal. RMR500ES: EU: DCF-77 signal: within 1 500 km (932 miles) of Frankfurt, Germany.
6
RMR500ESU: UK: MSF-60 signal: within 1 500 km (932 miles) of Anthorn, England. RMR500ESA: WWVB-60 signal: within 3200 km (2000 miles) of Fort Collins, Colorado. To enable / disable clock signal reception: Press and hold reception. to enable or to disable clock signal
2.
Press or to change the settings. The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (month day / day month), month and day. Press to confirm.
3.
RMR500ES / RMR500ESU: Time zone sets the clock +/23 hours from the received clock signal time. If you have deactivated the clock signal reception, do not set a value for time zone. RMR500ESA: Select the time zone: (0) Pacific, (+1) Mountain, (+2) Central or (+3) Eastern.
NOTE Reception takes 2-10 minutes. If the signal is weak,
it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search. Clock signal reception indicator:
STRONG SIGNAL WEAk / NO SIGNAL
TEMPERATURE AND HUMIDITY
To toggle temperature unit: Press °C / °F.
NOTE "HH. H" or "LL. L" will be displayed when the received
temperature is out of the specified temperature range.
MOLD ALERT
This product features moisture alert function for the prevention of mold. If the humidity is over 60%, the mold alert icon will flash, and will stop flashing if the humidity is less than 60%.
MANUALLY SET CLOCk
To set the clock manually, disable the clock signal reception first. Press and hold .
7
EN
EN
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30-50 km (9-3 mile) radius with 75% accuracy.
Sunny Partially Cloudy Cloudy Rainy Snowy
Temperature range Humidity range Power REMOTE UNIT (THGN500)
-5°C to 50°C (23°F to 22°F) 25% - 95% 600mAH rechargeable battery; 6V AC/DC adaptor (not included); 2 x CR2032 batteries (for backup)
BACkLIGHT
Press to activate LED backlight for 5 seconds.
RESET
Press RESET to return to the default settings.
SPECIFICATIONS
TYPE MAIN UNIT LxWxH Weight Signal frequency DESCRIPTION 130 x 80 x 130 mm (5. 1 x 3. 15 x 5. 1 in) 400 g (4. oz) without battery 433 MHz
50 x 22 x 96 mm (1. 9 x 0. 9 x 3. 8 in) Weight 63 g (2. 22 oz) without battery Signal frequency 433 MHz Number of channel Transmission range 30 m (00 ft) unobstructed Temperature range -20°C to 60°C (-4°F to 40°F) Humidity range 25% - 95% Power 1 x UM-3 (AA) . 5 V battery A) 1. 5 ) REMOTE UNIT (THGR122N) 92 x 60 x 20 mm LxWxH (3. 6 x 2. 4 x 0. 79 in) Weight 63 g (2. 22 oz) without battery Signal frequency 433 MHz Number of channel 3 Transmission range 30 m (00 ft) unobstructed Temperature range -20°C to 60°C (-4°F to 40°F) Humidity range 25% - 95% Power 2 x UM-4 (AAA) . 5 V battery A) 1. 5 ) LxWxH
PRECAUTIONS
· · Do not subject the unit to excessive force, shock, dust, temperature or humidity. [. . . ] Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.
ABOUT OREGON SCIENTIFIC
Visit our website (www. oregonscientific. com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: www2. oregonscientific. com/service/support. asp For international inquiries, please visit: www2. oregonscientific. com/about/international. asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this +ECO Clima Control (model: RMR500ES / RMR500ESU / RMR500ESA) is in compliance with the essential requirements and other relevant provisions of Directive 999/5/EC. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON RMR500ESU
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON RMR500ESU will begin.