Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OUTBACK POWER SYSTEMS GFX1312E. We hope that this OUTBACK POWER SYSTEMS GFX1312E user guide will be useful to you.
Lastmanuals help download the user guide OUTBACK POWER SYSTEMS GFX1312E.
You may also download the following manuals related to this product:
OUTBACK POWER SYSTEMS GFX1312E BROCHURE (174 ko)
OUTBACK POWER SYSTEMS GFX1312E INSTALLATION (874 ko)
Manual abstract: user guide OUTBACK POWER SYSTEMS GFX1312E
Detailed instructions for use are in the User's Guide.
[. . . ] International Series GFX Inverter/Charger
GFX1312E GFX1424E GFX1448E
Operator's Manual
About OutBack Power Technologies
OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, system communication components, as well as breaker panels, breakers, accessories, and assembled systems.
Contact Information
Telephone: +1. 360. 435. 6030 (North America) +1. 360. 618. 4363 (Technical Support) +1. 360. 435. 6019 (Fax) North America 19009 62nd Avenue NE Arlington, WA 98223 USA Support@outbackpower. com www. outbackpower. com +34. 93. 654. 9568 (Barcelona, Spain)
Address:
E-mail: Web Site:
Disclaimer
UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER'S RISK.
Warranty Summary
OutBack Power Technologies Inc. [. . . ] This order is assigned using a system display, such as the OutBack MATE. Examples of stacking configurations include "parallel" and "three-phase" configurations. Stacking requires an OutBack HUB product, as well as a system display. A system of four or fewer units may use the HUB4. Systems of up to ten units require the HUB10. All interconnections are made using CAT5 non-crossover cable. (See the International Series GFX Installation Manual for more stacking instructions. ) Each inverter needs to be assigned a status -- "master" or "slave". The master is the primary and most heavily used unit. Slave inverters provide assistance when the loads are more than the master can handle alone. Programming involves using the system display to assign a status and stacking value to the inverter on each port. See the system display and HUB manuals for programming instructions.
HUB4 Additional Ports Port 1 1ST MATE Port
MATE
Figure 6 IMPORTANT:
OutBack HUB4 and MATE
The master inverter must always be connected to port 1 on the HUB. Connecting it elsewhere, or connecting a slave to port 1, will result in backfeed or output voltage errors which will shut the system down immediately. Installing multiple inverters without stacking them (or stacking them improperly) will result in similar errors and shutdown. Although stacking allows greater capacity, the loads, wiring, and breakers must still be sized appropriately. Additional terminations and bus bars may be required. Overloading may cause the breakers to trip or the inverters to shut down.
CAUTION: Equipment Damage
The inverters in a stacked system should all be the same DC voltage, wattage, and model. Do not stack inverters of different wattages.
24
900-0112-01-00 Rev A
Operation
Parallel Stacking (Dual-Stack and Larger)
In parallel stacking, two or more inverters are stacked to create a single, common 230 Vac output.
The master provides the primary output. The slaves are connected to the same output and assist the master. The slave inverters can be programmed to activate on demand, reducing idle-power consumption. They will remain off until the loads exceed a certain threshold. A two-inverter system can continuously power 2. 6 2. 8 kVA of loads, depending on the inverter model. Up to ten inverters may be installed in a parallel arrangement. [. . . ] 17, 18, 19, 31, 34, 35, 36, 39, 40 Grid Use Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Grid/Generator Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Grid-Interactive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2, 26, 41, 46
C
Charging Absorption Stage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OUTBACK POWER SYSTEMS GFX1312E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OUTBACK POWER SYSTEMS GFX1312E will begin.