[. . . ] (1) Slight flowing noise of refrigerant in the refrigerating cycle (2) Slight rubbing noise from fan casing which is cooled and then gradually warmed as operation stops.
1
CONTROLS NAMES
The panel of 7000~9000Btu/h
ON/OFF
Cooler
HIGH COOL LOW COOL LOW FAN HIGH FAN OFF
The panel of 12000Btu/h
ON/OFF
SELECTOR
THERMOSTAT
WAIT FOR THREE MINUTES BEFORE RESTARTING
Cooler
HIGH COOL LOW COOL OFF LOW HIGH FAN FAN
The panel of 18000~24000Btu/h
SELECTOR THERMOSTAT SELECTOR
THERMOSTAT
WAIT FOR THREE MINUTES BEFORE RESTARTING
ON/OFF
Cooler
HIGH COOL MID COOL LOW COOL HIGH FAN MID FAN LOW FAN
Fig. 2
WAIT FOR THREE MINUTES BEFORE RESTARTING
OPERATION AIR DEFLECTORS
Vertical Air Deflectors When the auto louder switch is turned to "ON" position, the vertical air deflectors automatically move right and left, and sweep the jet of air alternately. The vertical air deflectors may be stopped at any position when the auto louder switch is turned "OFF" Horizontal Air Deflectors The horizontal air deflectors can be adjusted.
CAUTION The shape and position of the switches and indicators may vary from different, but their function are similar.
2
THERMOSTAT
The temperature gets lower from 1 to 5 is for cooling function.
CAUTION
The compressor operates continuously by setting the temperature dial to nearly "TEST". Do not set this dial to the setting as it is for testing purpose. [. . . ] The filter is behind the cover and to be pulled out from right hand side. Wash the air filter with water an detergent. Rinse with clean water and dry it before reinstalling.
Fig. 4
CAUTION
Do not use hot water above 400C for washing the air filter. Let the filter dry thoroughly in the shade before reinstalling. Do not operate the air conditioner with the filter removed.
AIR CLEANING FILTER
The air cleaning filter is attached to the air filter Wash the air cleaning filter as well when wash air filter. .
FRONT COVER, ETC
The front cover will accumulate dirt and dust. To clean it, wipe it with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened with warm water or mild soap, then wipe it again thoroughly with a soft dry cloth.
Hot Water
Benzene, acid, etc.
5
Never use hot water above 500C, benzene, gasoline, acid, thinner or brush to wipe off dirt because they will damage the plastic surface and the coating.
LONG OFF PERIOD MAINTENANCE
Operate the fan alone ("LOW FAN "or "HIGH FAN") for half a day to dry out the inside of the unit. Turn off power and remove plug from wall socket. After a long off period and going to use the air conditioner again , clean the CONDENSER (at the rear) and EVAPORATOR (at the front) fins by using a soft brush or vacuum cleaner.
CAUTION
Be careful not to damage the fins during the cleaning.
BEFORE ASKING FOR SERVICE
Check the following points before requesting for repairs or service. If the malfunction persists, please contact our customer service.
Faults
Does not operate
Cause
1 2 3 4 1
Is the power off?Is the operation dial set to "off'?Is the air filter remain full of dust or dirt?Is the sunlight fall directly on the unit?Is the air flow on the rear side obstructed?Leave a space of 500mm behind the rear side of the air condition?The doors or windows may be opened widely or there are other sources of heat in the room?The temperature dial may not set to the colder position. Is the ventilation damper opened?
2 3
Does not cool effectively
4
5
6
6
Installation Instruction
REMOVE ALL THE SHIPPING PARTS BEFORE INSTALLATION LOCATION
Select a location that can support the weight of the air conditioner and one that will not cause increased operation noise and vibration. Direct sunlight is unfavourable for efficient cooling. [. . . ] 13) (Available for Only) 6) Install the air conditioner cabinet on the installation shelf (not included) with screws. 12) 7) Carefully slide the unit back into the cabinet. 14) 8) Reinstall the retaining bracket, front panel and mounting screws. 16)
Fig. 10 Retaining bracket Fig. 9
Fig. 8
Wall Cabinet
Screw
Installation shelf Fig. 12 Fig. 11
9
Fig. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PALSONIC AAC90CW
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.