Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC AJ-DE77. We hope that this PANASONIC AJ-DE77 user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC AJ-DE77.
Detailed instructions for use are in the User's Guide.
[. . . ] FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications. This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. [. . . ] 210 25P STBY CMD OFF : Connector does not function. RETURN ACK
<INTERFACE>
Description No. /Item 208 PARITY 0000 NON : Parity bit is not used. 0001 ODD: An odd number of bits is used for the parity system. 0002 EVEN: An even number of bits is used for the parity system. These settings are for selecting whether the ACK code is to be returned when a command is received from RS-232C. 0000 0001 OFF : ACK code is not returned. Description These settings are for selecting the none, odd or even for the RS-232C parity bit.
This selects whether two or more VTRs are to be operated in synchronization.
This sets the ID information to be returned to the controller.
For selecting the method used to detect the STANDBY COMMAND signal input at the PARALLEL (25P) connector. 0000 OFF/ON : Each time active signals are detected, the STANDBY ON or STANDBY OFF mode is selected alternately. 0001 ON : When active signals are detected in the STANDBY OFF mode, the unit is transferred to the STANDBY ON mode. Nothing happens if they are detected during an operation in the STANDBY ON mode.
211 LOCAL 25P
This selects whether the RS-232C connector functions when the CONTROL switch has been set to REMOTE. 0000 0001 OFF : Connector does not function. 0000 MANU : Editing is not executed unless the illegal edit point is cleared or set again properly. 0001 AUTO : The edit points already input are automatically cleared.
303 STD/ NON-STD
This selects STD or NON-STD in accordance with the composite input signal. 0000 AUTO : Standard/non-standard signals are automatically identified and processed. 0001 STD : Standard signals are processed. (Forced STD) 0002 N-STD : Non-standard signals are processed. (Forced NON-STD) <Note> Use the non-standard (N-STD) setting when video or audio trouble occurs with signals from laser discs or a satellite. This selects the video signal processing. 0000 AUTO : Servo is synchronized with the input signal during recording and editing, or with the REF signal during playback. 0001 EXT : Servo is synchronized at all times with the REF signal. This sets the channel assignments for the controller's analog audio preset when editing the digital audio of the VTR using a controller which does not have a digital audio edit preset control function. This selects the channel concerned when the VTR CH1 edit preset is set in compliance with the ON or OFF presetting for the analog audio signals designated by the controller. [. . . ] data = AJ-SD930BP or AJ-DE77
74
SDTI interface
Digital data input/output operations using the SDTI format (compressed digital interface) are enabled by installing the AJ-YAC930G SDTI board (optional accessory) in this unit. <Notes> SDTI (Serial Data Transport Interface) complies with the SMPTE 305M standard. The data stream format transferred via the SDTI complies with the SMPTE 321M standard.
SIGNAL GND
Reference signal generator Source
AES/EBU
AC IN
CH1/2 IN
ANALOG
VIDEO IN
ON
REMOTE
REMOTE IN/OUT
75
OFF
ANALOG SDI
CH1 PUSH AUDIO PUSH CH2 IN
PUSH TC
IN
IN
OUT
Y CH3/4 IN
1 REMOTE OUT CH3 PUSH
CH1/2 OUT
PB
REF VIDEO IN
ON
PUSH CH4
TC OUT
ACTIVE THROUGH
2
ENCODER REMOTE
75
CH3/4 OUT
PR
OPTION
OFF
CH1 RS-232C
AUDIO OUT
CH2
MON L
(SUPER)
3
OPTION
Y 1 VIDEO OUT
IN PARALLEL CH3 CH4 MON R
SDTI OUT
1
PB
(WFM)
2
PR
(SUPER)
3
2
Precautions to observe when using the SDTI signals
O The unit can record only if the SDTI input signals are 1a transfer signals in the DVCPRO50 or DVCPRO format selected by setup menu No. However, when playback signals other than normal 1a playback signals have been input, there is no guaranty for the pictures and sound recorded or for pictures and sound with EE. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC AJ-DE77
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC AJ-DE77 will begin.