Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC AJ-LT75P. We hope that this PANASONIC AJ-LT75P user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC AJ-LT75P.
Detailed instructions for use are in the User's Guide.
[. . . ] FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications. This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. [. . . ] 0000 0001 OFF : ACK code is not returned. Description These settings are for selecting the none, odd or even for the RS-232C parity bit.
This selects whether two or more VTRs are to be operated in synchronization.
This sets the ID information to be returned to the controller.
For selecting the method used to detect the STANDBY COMMAND signal input at the PARALLEL (25P) connector. 0000 OFF/ON : Each time active signals are detected, the STANDBY ON or STANDBY OFF mode is selected alternately. 0001 ON : When active signals are detected in the STANDBY OFF mode, the unit is transferred to the STANDBY ON mode. Nothing happens if they are detected during an operation in the STANDBY ON mode.
211 LOCAL 25P
This selects whether the RS-232C connector functions when the CONTROL switch has been set to REMOTE. 0000 0001 OFF : Connector does not function. ON : Connector functions.
This selects whether the PARALLEL (25P) connector is to function when the CONTROL switch is at the LOCAL position. 0000 0001 OFF : Connector does not function. ON : Connector functions.
212 SD955A MASTER PORT
205 BAUD RATE
These settings are for selecting the RS-232C communication speed (baud rate). 0000 0001 0002 0003 0004 0005 300 600 1200 2400 4800 9600
For selecting the remote control connector to control the slave when the unit is used as the master during deck-to-deck operations. 0000 IN/OUT : The IN/OUT connector is used. (Forced NON-STD) <Note> Use the non-standard (N-STD) setting when video or audio trouble occurs with signals from laser discs or a satellite. This selects the video signal processing. 0000 AUTO : Servo is synchronized with the input signal during recording and editing, or with the REF signal during playback. 0001 EXT : Servo is synchronized at all times with the REF signal. This sets the channel assignments for the controller's analog audio preset when editing the digital audio of the VTR using a controller which does not have a digital audio edit preset control function. This selects the channel concerned when the VTR CH1 edit preset is set in compliance with the ON or OFF presetting for the analog audio signals designated by the controller. 0001 CH1 : Compliance with analog CH1 edit preset. 0002 CH2 : Compliance with analog CH2 edit preset. 0003 CH1+2 : Compliance with either analog CH1 or CH2 edit preset.
304 SERVO REF
305 EDIT RPLCE1
The underlined items indicates the initial setting.
40
Setup menus
USER menu
No. /Item 309 EDIT RPLCEC
<EDIT>
Description No. /Item 320 VAR FWD MAX Description This sets the maximum SLOW FWD speed. 0000 +4. 1 : +4. 1 (+3. 1)a speed 0001 +1. 85 : +1. 85a speed 0002 +1 : +1a speed <Notes> OThe value for the DV/DVCAM tape is shown in parenthesis ( ). OAt any speed setting other than +4. 1, the phase cannot be synchronized from the editing controller. [. . . ] data = AJ-LT75PP or AJ-SD955AP SD955A
73
SDTI interface
Digital data input/output operations using the SDTI format (compressed digital interface) are enabled by installing the AJ-YAC930G SDTI board (optional accessory) in this unit. <Notes> SDTI (Serial Data Transport Interface) complies with the SMPTE 305M standard. The data stream format transferred via the SDTI complies with the SMPTE 321M standard.
SIGNAL GND
Reference signal generator Source
AES/EBU
AC IN
CH1/2 IN
ANALOG
VIDEO IN
ON
REMOTE
REMOTE IN/OUT
75
OFF
ANALOG SDI
CH1 PUSH AUDIO PUSH CH2 IN
PUSH TC
IN
IN
OUT
Y CH3/4 IN
1 REMOTE OUT CH3 PUSH
CH1/2 OUT
PB
REF VIDEO IN
ON
PUSH CH4
TC OUT
ACTIVE THROUGH
2
ENCODER REMOTE
75
CH3/4 OUT
PR
OPTION
OFF
CH1 RS-232C
AUDIO OUT
CH2
MON L
(SUPER)
3
OPTION
Y 1 VIDEO OUT
IN PARALLEL CH3 CH4 MON R
SDTI OUT
1
PB
(WFM)
2
PR
(SUPER)
3
2
Precautions to observe when using the SDTI signals
O The unit can record only if the SDTI input signals are 1a transfer signals in the DVCPRO50 or DVCPRO format selected by setup menu No. However, when playback signals other than normal 1a playback signals have been input, recorded and EE picture and sound are not guaranteed. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC AJ-LT75P
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC AJ-LT75P will begin.