User manual PANASONIC AK-HBU931P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC AK-HBU931P. We hope that this PANASONIC AK-HBU931P user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC AK-HBU931P.


Mode d'emploi PANASONIC AK-HBU931P
Download
Manual abstract: user guide PANASONIC AK-HBU931P

Detailed instructions for use are in the User's Guide.

[. . . ] When installed in the multi-format camera, it enables a large lens to be mounted, thus yielding the same range of operations as that afforded by a larger camera. Operating precautions Be absolutely sure to supply the build-up unit's power from the multi-format camera. Dropping the viewfinder or subjecting it to strong impact may cause malfunctioning and/or accidents. Operate the unit within a temperature range of 32oF to 104oF (0oC to + 40oC). Operation in locations below 32oF or above 104oF may adversely affect the internal parts. [. . . ] ; Optical fiber connector OPT FIBER connector (EDW. 3K. 93C. CLC made by LEMO) Pin No. 1 2 3 4 5 6 Function Optical fiber Optical fibe Control wire, hot Control wire, cold AC 240V live AC 240V neutral + ­ + ­ Polarity Signal flow CAM#CCU CCU#CAM CAM!#CCU CAM!#CCU CCU#CAM CCU#CAM 1 VF power switch [VF POWER] This is used to set the viewfinder's power to ON or OFF. When it is lighted, the viewfinder's power is OFF. 2 Front tally ON/OFF switch [FRONT TALLY] This is used set the viewfinder and lens tally lamp to ON or OFF. When the lamp is lighted, the tally lamp is OFF. 3 CENTER marker switch [CENTER MARKER] This is used to set the center marker to ON or OFF. 4 CURSOR switch This is used to set the cursor on the viewfinder screen to ON or OFF. 5 Cursor memory switch 1 If this switch is held down while the cursor switch is ON, the current cursor status is stored in the memory. If the cursor switch is set to ON after the cursor memory switch 1 has been pressed, the cursor which was stored in the memory by the cursor memory switch 1 can be called. 6 Cursor memory switch 2 If this switch is held down while the cursor switch is ON, the current cursor status is stored in the memory. If the cursor switch is set to ON after the cursor memory switch 2 has been pressed, the cursor which was stored in the memory by the cursor memory switch 2 can be called. 7 H-POSI control [H-POSI] This is used to adjust the horizontal position of the cursor. 8 V-POSI control [V-POSI] This is used to adjust the vertical position of the cursor. 9 Width control [WIDTH] This is used to adjust the width of the cursor. : Height control [HEIGHT] This is used to adjust the height of the cursor. < AC outlet An AC output of up to 200 VA can be supplied to this outlet. = AC outlet circuit-breaker This is the circuit-breaker for the AC outlet. If the AC output load is too high and the circuit breaker has been tripped, reduce the load, and then reset the circuit breaker by pressing the circuit breaker button. > Power main circuit breaker This is the main circuit-breaker for the unit's power supply. If the circuit breaker has been tripped by an overcurrent or for some other reason, check the cause, take the appropriate measures to remedy the problem, and then reset the circuit breaker by pressing the circuit breaker button. AC OUTLET reset switch This cuts off the AC output when it drops below the minimum voltage that can be supplied. When this has happened, the outlet can be reset by pressing this reset switch without turning off the camera's power. @ AC OUT alarm display This lights when the AC output voltage range exceeds 10%. 6 Controls and their functions ; 4:3 MARKER switch This is the 4:3 marker ON/OFF switch. [. . . ] DTL CLIP OFF ON OFF OFF CONTROL BLACK WHITE SHADING R G B KNEE WHITE CLIP BLK GAMMA UNDO PED FLAME GAMMA GAIN HD. DTL MATRIX SYSTEM FUNC ND FILTER HEAD CC CAP 100 25 6. 3 1. 6 STORE 1. 1 4. 3 6. 3 8. 0 SCENE FILE 1 2 3 4 5 MONITOR R G B SEQ ENC 1 2 3 4 GAIN G 5 R B -6 -3 0 GAIN 3 6 9 12 SHUTTER R BLACK G B ON VAR DTL FULL AUTO PED IRIS ACTIVE ALARM CALL IRIS OPEN CABLE SHORT ALARM FUSE 250V 2. 5A TALLY/CALL M-PEDACTIVE LENS EXT X0. 8 FUSE 125V 5A PED SENSE LEVEL OFF MAIN HEAD POWER COXN PGN1 PGN IRIS RANGE PGN2 PUSH PRIVATE MIC ON OFF PTT Remote Operation Panel AK-HRP930P Camera control unit (AK-HCU931P) Remote operation panel (AK-HRP931P) 9 External dimension drawings VF POWER FRONT TALLY CENTER MARKER ON/OFF CURSOR 1 2 RET A RET B USER SEL VF MARKER ON H­POSI V­POSI WIDTH HEIGHT VF DETAIL MONI SEL R Y/G G B EXT OFF 1 2 3 4 5 FILTER LOCAL A B C D E MENU SELECT PIP x0. 8 ND CC 23-1/15z (585 mm) 12-5/8z (320 mm) 10 13-5/16z (337. 5 mm) Specifications Power supply: AC 220 V (supplied from CCU) Power consumption: 8 W (main unit only) 1indicates safety information. Switch functions: Adjustment functions: Operating temperature range: Storage temperature range: Operating ambient humidity: Dimensions: Weight: Accessories Operating Instructions (k1) AC OUT reset, viewfinder power, front tally ON/OFF, CENTER marker, CURSOR, cursor memory 1, cursor memory 2, 4:3 MARKER, ND filter selection, LOCAL, CC filter selection, menu ON/OFF, menu JOG, RET A switch, RET B switch, user, VF DETAIL, MONITOR output selection, P in P function ON/OFF, P in P position selection H-POSI, V-POSI, WIDTH, HEIGHT, 4:3 brightness modulation level 32oF to 104oF (0oC to +40oC) ­4oF to 140oF (­20oC to +60oC) Less than 85% 12-5/8(W)k13-5/16(H)k23-1/16(D) inch (excluding protrusions) (320k337. 5k585 mm) Approx. 31. 9 lbs (14. 5kg) Weight and dimensions shown are approximate. Specifications are subject to change without notice. 11 PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: 3330 Cahuenga Blvd W. , Los Angeles, CA 90068 (323) 436-3500 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835 Central Region: 1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200 WESTERN ZONE: 3330 Cahuenga Blvd W. , Los Angeles, CA 90068 (323) 436-3500 Government Marketing Department: 52 West Gude Drive, Rockville, MD 20850 (301) 738-3840 Broadcast PARTS INFORMATION & ORDERING: 9:00 a. m. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC AK-HBU931P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC AK-HBU931P will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag