If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC AK-HRP900P. We hope that this PANASONIC AK-HRP900P user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC AK-HRP900P.
Detailed instructions for use are in the User's Guide.
[. . . ] Camera Controller Model
AK-HRP900P
Before attempting to connect, operate or adjust this product, please read these instructions completely and save this manual for future use.
For Your Safety
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. [. . . ] With the zoom operation lever direction change switch T set to [REV], the zoom can be operated in the opposite direction. ; Focus adjust lever [FOCUS FAR/NEAR] Used to adjust the lens focus. The focus can be controlled in speed variable fashion by regulating the shifting angle of this lever. With the focus adjust direction change switch U set at [NOR], when this lever is shifted to [FAR], the focus is adjusted to a far distance, and when shifted to [NEAR], the focus is adjusted to a near distance. With the focus adjust direction change switch U set to [REV], the focus can be adjusted in the opposite direction. < Operation panel active switch [OPERATE] This is an active switch for panel function. It can be operated when the switch is lighted. It does not work when the switch is not lighted.
6
Controls and their Functions
= Alarm indication LED [ALARM] It lights up when an alarm is generated (in case of fan stop, wrong communication speed, etc. ). Note: In case of wrong communication speed, change the DIP SW position in the unit to match the camera and communication speed so that the alarm goes out. > Scene file select switch [SCENE] Used to select the scene file previously set on the camera. Note: With [PRESET] selected, it results in the factory-adjusted setting. Mode select switch [MODE] Used to select the camera color bar signal, test signal and camera picture signal. With the switch set to [BAR], [TEST], the color bar signal and the test signal are output from the monitor signal output terminal of this unit. With it set to [CAM], the picture taken by the camera is output. @ Auto white start switch [AUTO WHITE] With this switch pressed, the white balance is automatically adjusted. During the operation, WHTE LED blinks, and it goes out when the adjustment is normally finished. In case of NG, it lights up for a while and then goes out. Note: It does not operate when the mode is [BAR]. A Auto black start switch [AUTO BLACK] With this switch pressed, the lens is automatically closed, and the black balance is adjusted. During the operation, BLACK LED blinks, and it goes out when the adjustment is normally finished. In case of NG, it lights up for a while and then goes out. B R/B gain adjust volume [GAIN] Used to adjust the R/B signal gain of the camera. [. . . ] When no swivel stand is used, connect both of the motor-driven zoom lens iris control cable and remote (zoom/focus) cable to the camera. (see page 13) When a swivel stand is used, connect the iris control cable to the camera, and the remote (zoom/focus) cable to the swivel stand. (see the illustration below) For the connection system of each unit, refer to pages 14 to 16.
Connect the motor-driven zoom lens iris control cable to the camera, and the remote (zoom/focus control) cable to the swivel stand. If the motor-driven zoom lens remote (zoom/focus control) cable is connected to the camera, the lens cannot be controlled.
Iris control cable
To iris connector
BREAKER ZOOM/ FOCUS
1 SDI OUT 2
1/ F
Remote (zoom/focus control) cable
1394
CONTROL IN IP/RP
DC12V IN C S OP
G/L I N
Pb OUT
Pr /SDI OUT
Y/VIDEO OUT
12
SDI IN
LENSE I/F CAMERA I/F
ND/EXT
To lens interface connector
How to Connect
_Lens connection in the case of no swivel stand
_How to mount the lens
A lens of any maker's can be used provided that it is a bayonet type (B4 mount) lens of 2/3 inch standard. * 1 Turn the lens fixing ring knob counterclockwise and remove the lens mount cap. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC AK-HRP900P
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.