User manual PANASONIC CS-E28MKES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC CS-E28MKES. We hope that this PANASONIC CS-E28MKES user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC CS-E28MKES.


Mode d'emploi PANASONIC CS-E28MKES
Download
Manual abstract: user guide PANASONIC CS-E28MKES

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS-E24MKES CS-E28MKES CU-E24MKE CU-E28MKE ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. FRANÇAIS Avant d'utiliser l'appareil, lisez ce mode d'emploi dans son intégralité et conservez-le pour toute référence ultérieure. ESPAÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. DEUTSCH Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf. [. . . ] · After initialization, the human activity sensor will start to detect the level of heat source & movement, the unit adjusts the temperature and airflow to keep you comfort consistently. Heat Source & Movement Cool/Dry Mode Set Temperature Set Fan Speed Heat Mode Set Temperature Set Fan Speed Low +1°C +1 tap* High Normal None +2°C -1°C +1 tap +0. 3°C -2°C -2°C Medium Fan · This operation reduces air dryness and provides you with a comfortable living environment during COOL mode only. · When vertical airflow direction is set to AUTO, it stops at lower position to avoid cold air contact. However, you can adjust the louver direction manually. 8 TO SWITCH BETWEEN POWERFUL & QUIET POWERFUL QUIET POWERFUL/QUIET * For first 15 minutes or until set temperature is reached. · Human activity sensor will also scan for area of heat source and movement in a room. Human activity indicator Heat source & movement At left area of the room At right area of the room At centre area or multiple areas of the room. · The unit will determine the heat source & movement hotspot, and automatically adjust horizontal airflow direction louver either fix at predetermined position or swing left/right. Detection area (top view) 7m 120º POWERFUL/ QUIET NORMAL POWERFUL TO REACH TEMPERATURE QUICKLY · This operation stops automatically after 20 minutes. TO ENJOY QUIET OPERATION · This operation reduces airflow noises. · When this operation is activated, the indicator brightness will be dimmed. QUIET · When manual AIR SWING is selected, the ECONAVI and AUTO COMFORT operation will be cancel. · Sensor may not detect moving objects further than 7m away or beyond detection angle. · Sensor sensitivity is influenced by indoor unit location, movement speed, temperature range, etc. · The sensor may mistakenly detects pets, sunlight, certain lighting, fluttering curtains and light reflection as human being. NOTES PATROL/ POWERFUL/ QUIET AUTO COMFORT POWERFUL/ QUIET AUTO COMFORT , , , · Can be activated in all modes and can be cancelled by pressing the respective button again. , , · Cannot be selected at the same time. · Cannot be activated during "MILD DRY COOLING" operation is activated. 7 ENGLISH TO MONITOR HUMAN PRESENCE & ACTIVITY FOR ENERGY SAVING & COMFORT REMOTE CONTROL 11 Press and hold for 5 seconds to dim or restore the unit's indicator brightness. Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press to restore the remote control's default setting. TO SET THE TIMER · 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time. · Complete below procedures to set each timer: ON 12 Cancel 2 13 1 Cancel OFF SET 14 Not used in normal operations. · TIMER ON SET 2 3 11 12 14 1 OFF CANCEL AC RC · 13 · SET CHECK CLOCK RESET · · · Set the Confirm time Example of application at living room: Morning: ON at 07:00 (Wake up) OFF at 08:00 (Out for work) Evening: ON at 17:00 (Back home) OFF at 22:00 (Sleep) ON To cancel ON or OFF timer, press or OFF to select respective or then press CANCEL. If timer is cancelled manually or due to power failure, ON you can restore the timer again by pressing or SET to select respective or then press . OFF Upcoming timer will be displayed and will be activated in sequence. [. . . ] NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY AND UNPLUG then please consult authorized dealer under the following conditions: · Abnormal noise during operation. · Water/foreign particles have entered the remote control. · Circuit breaker switches off frequently. · Power cord becomes unnaturally warm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC CS-E28MKES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC CS-E28MKES will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag