User manual PANASONIC CU-B18DBE5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC CU-B18DBE5. We hope that this PANASONIC CU-B18DBE5 user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC CU-B18DBE5.


Mode d'emploi PANASONIC CU-B18DBE5
Download
Manual abstract: user guide PANASONIC CU-B18DBE5

Detailed instructions for use are in the User's Guide.

[. . . ] F566077 Operating Instructions Air Conditioner Indoor Unit CS-F14DB4E5 CS-F18DB4E5 CS-F24DB4E5 CS-F28DB4E5 Outdoor Unit Inverter Model (HBE5 Series) (DBE5, DBE8 Series) O PE N C LO SE CS-F34DB4E5 CS-F43DB4E5 CS-F50DB4E5 C LO SE O PE N ENGLISH 2 ~ 11 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. ESPAÑOL 12 ~ 21 Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. ITALIANO 22 ~ 31 Prima di utilizzare l'unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro. DEUTSCH 32 ~ 41 Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf. [. . . ] · If the main power is switched off for an hour or more, the clock and timer will need to be set again. HINTS · Set the temperature 1°C higher in cool mode or 2°C lower in heat mode than the desired temperature to achieve a 10% power saving. · Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. ODOUR REMOVING · Applicable for all models. · Helps to remove unpleasant odour from the surrounding area during operation. · To enable the odour removing function, press the ODOUR WASH once. · To cancel, press the respective button again. ODOUR CLEAR · Applicable for Inverter model only. · To remove odour and minimize the growth of odour causing moulds in the air conditioner's interior section. · To enable this function, press the ODOUR WASH for more than 3 seconds. · The unit will automatically perform Fan and Heating modes for approximately 20 minutes and then stops automatically. · Recommended to open the windows during this operation. 7 ENGLISH FAN SPEED TO SET DAILY TIMER TO SET WEEKLY TIMER OPERATION DETAILS · Weekly timer is only applicable for wired remote MODE control, press for 3 seconds to select daily timer or weekly timer. · Daily timer and weekly timer could not be set at the same time. · Promotes energy saving by allowing you to set up to 6 timers in any given day. · Same timer program cannot be set on the same day. Enter timer mode. FAN SPEED MON TUE WED THU FRI SAT SUN AUTO AUTO ON OFF / O CZ-RD513C AIR SWING AUTO 123 OFF / ON CZ-RD513C TIMER/CLOCK MODE MODE TEMP/ A/C No. UP UP SET TIMER/CLOCK MODE UP SET FAN SPEED SELECT DOWN CANCEL AUTO MANUAL DOWN SELECT DOWN CANCEL ECONOMY CHECK ODOUR WASH AIR SWING VENTILATION TEST RUN FILTER RESET ECONOMY CHECK ODOUR WASH VE Will light up if Timer operation is selected 6 different programs can be set in a day (1 ~ 6) TIMER/CLOCK MODE UP SET SELECT DOWN CANCEL 2. Select the day. TIMER 1 2 3 4 5 6 MON TUE WED THU FRI SAT SUN Indicate the selected day ON Time to be OFF selected (Interval 10 minutes) OFF-Timer. To automatically switch "OFF" the unit. To automatically switch "ON" the unit. The display will show the program for each of the selected day. Modify Or Add Timer · Perform check timer operation to select the day. Repeat steps 4 to 8 to modify existing timer program, or add any new timer program. [. . . ] If problem persist, please consult your nearest authorized dealer. FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE · Checking of remote control batteries (wireless remote control). · No obstruction at air inlet and air outlet vents. · After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: 8°C Heating: 14°C NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then CALL Authorized Distributor under the following conditions: · Abnormal noise during operation. · Water/foreign particles have entered the remote control. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC CU-B18DBE5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC CU-B18DBE5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag