Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC CU-C281KR. We hope that this PANASONIC CU-C281KR user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC CU-C281KR.
Detailed instructions for use are in the User's Guide.
[. . . ] It could cause electric shock or fire.
Do not operate the unit with wet hands. It could cause an electric shock.
Do not insert finger, sticks or other objects into the units. It could lead to physical injury and cause damage to the units.
Do not be directly exposed to the cold airstream for too long. It could lead to health problems.
If there is a smell of burning, stop the air conditioner and disconnect the power supply. [. . . ] Release the button when the louver is at the desired position.
Press
SWING
The vertical airflow direction louver will swing up and down automatically.
MANUAL
To stop the automatic airflow direction operation, press
button.
FAN Air Circulation Operation.
When the room temperature reaches the setting temperature, operation commences at Low airflow volume. It stops when the room temperature drops to 2°C below the setting temperature (It is useful when using a heater).
Range of louver adjustment.
Air Circulation
Cooling Soft Dry
Automatic Airflow Volume
The speed of the indoor fan is adjusted automatically according to the operation. The indoor fan stops occasionally during cooling operation.
34° 57°
10
Setting the Timer
If there is a power failure.
To reset the Timer. (Example) If the OFF Timer has been set.
OFF-TIMER SET
Even if there is a power failure, the setting time is still stored in the memory because the remote control is a battery operated type.
<Note> Regarding remote control.
If the current time is not set correctly, correct Timer setting will not be possible. When the Timer is set, the current time display will vanish.
O
P
E
N
[RESET] points will clear the memory once they are shorted. [B A] switch is used when two air conditioners units have been installed in one room. Please consult your dealer.
11
To set the current time.
Set hours and minutes
TIME
. . . to advance the time . . . to reverse the time
To set the Timer.
OFF Timer
OFF-TIMER
Set hours and minutes
TIME
. . . to increase 10 minutes each step. . . . to decrease 10 minutes each step.
SET
The "OFF-TIMER" will blink.
The Timer indication lamp at main unit will light up. LED colour: Orange.
ON Timer
ON-TIMER
Set hours and minutes
TIME
. . . to increase 10 minutes each step. . . . to decrease 10 minutes each step.
SET
The "ON-TIMER" will blink.
The Timer indication lamp at main unit will light up. LED colour: Orange.
To cancel the Timer.
OFF Timer
OFF-TIMER CANCEL
The Timer indication lamp at main unit will go off. (The operation indication lamp will switch off. )
OFF/ON remote control signal receiving sound
The Remote Control signal receiving sound can be omitted as desired. To switch OFF the signal receiving sound, press Auto Operation Button for 10 seconds or more. At the same time, Automatic Operation starts. (To switch ON, press Auto Operation Button once more for 10 seconds or more. )
14
Operation Hints
Adjust room temperature properly. Set the temperature 1°C higher than actually desired. Approximately 10% of electricity costs can be saved. Blockage in the air filter reduces the airflow and lowers the cooling or heating. Otherwise, about 6% of electricity cost will be wasted.
Prevent wastage with the Timer. Use Timer when sleeping or going out to save electricity cost.
Do not block the air outlet vents at outdoor unit. Otherwise, it will lower the cooling or heating performance.
15
Make sure that the doors and windows are shut. Otherwise, cooling and heating performance will be reduced and electricity cost is wasted.
Keep blinds or curtains closed. [. . . ] Are all windows and doors closed?
Air conditioner operation noise too loud.
Is the installation work slanted?Is the front grille closed properly?
Call the dealer immediately
If the following conditions occur, immediatel pull out the power plug or turn off the power breaker
Abnormal noise is heard during operation.
Switches or buttons do not operate properly.
Water or foreign material gets into the remote control by mistake.
The circuit breaker switches off frequently.
Water leaks from the indoor unit.
Power supply cord and plug become unusually warm.
20
Y WARNING
(1) REMOVE POWER PLUG OR DISCONNECT FROM THE MAINS BEFORE SERVICING THIS APPLIANCE. (3) THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION. (4) YOUNG CHILDREN SHOULD BE SUPPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.
IMPORTANT
1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC CU-C281KR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC CU-C281KR will begin.