User manual PANASONIC CU-CE9NKE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC CU-CE9NKE. We hope that this PANASONIC CU-CE9NKE user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC CU-CE9NKE.


Mode d'emploi PANASONIC CU-CE9NKE
Download
Manual abstract: user guide PANASONIC CU-CE9NKE

Detailed instructions for use are in the User's Guide.

[. . . ] Indoor Unit Outdoor Unit CS-CE9NKE CS-CE12NKE CU-CE9NKE CU-CE12NKE ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. F568751 ENGLISH TABLE OF CONTENTS SAFETY PRECAUTIONS REMOTE CONTROL INDOOR UNIT TROUBLESHOOTING INFORMATION QUICK GUIDE Thank you for purchasing Panasonic Air Conditioner OPERATION CONDITION Use this air conditioner under the following temperature range 4~5 6~7 8 9 10~11 BACK COVER Temperature (°C) COOLING HEATING Max. Indoor *DBT *WBT 32 23 16 11 30 16 Outdoor *DBT *WBT 43 26 16 11 24 18 -15 -16 NOTICE: • When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly and outdoor unit might stop for protection control. * DBT: Dry bulb temperature * WBT: Wet bulb temperature NOTE : The illustrations in this manual are for explanation purposes only and may differ from the actual unit. [. . . ] ENGLISH 5 REMOTE CONTROL Press the remote control’s button 1 Maximum distances: 8m TO TURN ON OR OFF THE UNIT • Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly. 2 TO SET TEMPERATURE INDICATOR POWER/DEICE (Green/Blue) TIMER (Orange) • Selection range: 16°C ~ 30°C (Not applicable for FAN mode). € Operating the unit within the recommended temperature could induce energy saving. 3 TO SELECT OPERATION MODE Remote Control display AUTO HEAT COOL DRY FAN FAN SPEED AIR SWING HEAT mode - To enjoy warm air • Unit takes a while to warm up. The power indicator blinks during this operation. € Unit may stops warm air supply for deice. The deice indicator ON during this operation. COOL mode - To enjoy cool air • Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. DRY mode - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation. FAN mode - To circulate air in the room 1 AUTO mode - For your convenience • During operation mode selection the power indicator blinks. € Unit selects operation mode every 10 minutes according to temperature setting and room temperature. 4 TO SELECT FAN SPEED (5 OPTIONS) OFF/O MODE N 3 2 TEMP AIR SW ING FAN SP EED TIMER ON 5 4 6 7 9 SET 1 OFF CANCE L AC SET CH ECK CL OCK RESET RC FAN SPEED 2 3 • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. 6 6 7 8 9 TO SET THE TIMER • 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time. € Complete below procedures to set each timer: ON 1 Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Cancel 2 TIMER Cancel OFF SET • • • • • • Set the Confirm time Example of application at living room: Morning: ON at 07:00 (Wake up) OFF at 08:00 (Out for work) Evening: ON at 17:00 (Back home) OFF at 22:00 (Sleep) ON To cancel ON or OFF timer, press or OFF to select respective or then press CANCEL. If timer is cancelled manually or due to power failure, ON you can restore the timer again by pressing or SET to select respective or then press . oFF Upcoming timer will be displayed and will be activated in sequence. When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time. Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation on the back cover. Select ON or OFF timer ENGLISH 7 Press and hold for 5 seconds to dim or restore the unit’s indicator brightness. INDOOR UNIT • Switch off the power supply and unplug before cleaning. [. . . ] 1 2 SET 3 2 Press until you hear beep sound, then write down the error code. 3 Press for 5 seconds to quit checking. OFF CANCEL AC RC Note: • For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts. SET CHECK CLOCK RESET 4 Turn the unit off and reveal the error code to authorized dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC CU-CE9NKE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC CU-CE9NKE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag